The NI PXIe-4141 is a high-channel-count, high-speed, precision source measure unit (SMU) with four identical SMU channels per PXI Express slot.
The NI PXIe-4141 is a high-channel-count, high-speed, precision source measure unit (SMU) with four identical SMU channels per PXI Express slot.
Each SMU offers 4-quadrant operation to source or sink ±10 V at ±100 mA. With integrated remote (4-wire) sensing and current measurement sensitivity of 10 pA, the NI PXIe-4141 is ideal for precision measurements including accurate characterisation of idle currents.
Specifications:
| General | |
| Product Family | Power Supplies |
| Form Factor | PXI Platform |
| PXI Bus Type | PXI Express |
| Part Number | 781743-01 |
| Operating System/Target | Real-Time , Windows |
| LabVIEW RT Support | Yes |
| Triggering | SoftwareTrigger , ExternalTrigger , InternalTrigger |
| External Clocking | No |
| I/O Connector | 25-pin D-Sub |
| Product Name | NI PXIe-4141 |
| Analog Output | |
| Channels | 4 |
| Resolution | 18 bits |
| Timing | Hardware |
| Update Rate | 100 kS/s |
| Current Drive Single | 100 mA |
| Current Drive All | 400 mA |
| Output Impedance | -100 kOhm , 100 kOhm |
| Max Voltage | -10 V , 10 V |
| Maximum Voltage Range Accuracy | 600 µV |
| Maximum Voltage Range Sensitivity | 10 µV |
| Minimum Voltage Range | -10 V , 10 V |
| Minimum Voltage Range Accuracy | 600 µV |
| Min Voltage Range Sensitivity | 10 µV |
| Max Current Range | -100 mA , 100 mA |
| Maximum Current Range Accuracy | 15 µA |
| Maximum Current Range Sensitivity | 100 nA |
| Minimum Current Range | -10 µA , 10 µA |
| Minimum Current Range Accuracy | 1.5 nA |
| Min Current Range Sensitivity | 10 pA |
| Output Quadrants | Quadrant III , Quadrant II , Quadrant IV , Quadrant I |
| Max Quadrants Per Channel | 4 |
To find out more about the NI PXIe, kindly log on to http://sine.ni.com/ds/app/doc/p/id/ds-359/lang/en
For a quick response use the contact box on the right, call us or visit our website.
Contact National Instruments
National Instruments
Visit Website
Contact Details
Send Request39 Followers
About
Follow this supplier for a monthly bulletin featuring any recent updates they publish.
More related items
-
ATX Server Board | IMBA-C604ENSend Request
-
Data Acquisition System | imc SpartanSend Request
-
Data Logging DevicesSend Request
-
DNA-AI-217 Rugged Analog Input Board for Test & Measurement TasksSend Request
-
SBC | Intel Atom-based 3.5-inch | IB883Send Request
-
Compact Particle Sizer - FRITSCH ANALYSETTE 22Send Request