Our monitoring and alarm system is very flexible and be customised to suit your application requirements.
Australian Standard AS5034-2005 (Installation and use of inert gases for beverage industry) classifies a nonnaturally ventilated area as any area which is neither outdoor nor naturally ventilated and then give some common example of these areas as: underground cellars and cool rooms.
The same standard then states that these areas shall be protected by the following mechanisms:
- Gas Monitoring and alarms (Mandatory)
- Safe System of entry and work (Mandatory) etc.
Our CO2/O2 Monitoring system for Cellars and Storage Areas is the ideal gas monitor and alarm system for these applications – it allows monitoring of both high levels of Carbon Dioxide (CO2) and/or low levels of Oxygen (O2).The gas monitor and alarm system is highly reliable and flexible for the various applications.
The gas monitor and alarm system can be used as a single (CO2 only) or Dual (CO2/O2) system (or any other configuration) and comes fitted with Flashing Beacon and a Loud buzzer as standard.Local LCD readout and LED’s on the front indicate the level of gas present and which alarm is reached and/or the system needs maintenance. Automatic latching of the alarm is user selectable (password protected).
For underground cellars, storage areas and cold rooms with multiple entries the system can interface with up to three remote alarm boxes that can be mounted inside the room and at the each entry.Our monitoring and alarm system is very flexible and be customised to suit your application requirements – it can be set to monitor:
- CO2 Only
- O2 Only
- CO2/O2
- Dual CO2 or
- Dual O2
Specifications of CO2/O2 Monitoring & Alarm System as follows:
- MX 32 Controller
- Continuous monitoring
- Wall Mount Enclosure
- LCD display
- Audio Alarm (EXTERNAL Buzzer)
- Visual Alarm (Coloured LED)
- Individual alarm outputs per channel
- Common fault alarm
- Up to 95% Relative Humidity
- 24VDC, 115VAC or 230VAC
- C-tick
- O2 Detection
- Polycarbonate Housing
- Optional Display reading – Not included
- 15 to 32VDC (powered through MX32)
Complete with: - O2 Cell (0 to 30%)
- Electrochemical Type
- -20C to +50C
- up to 95% RH (non condensing)
- Atmospheric Pressure (+/- 10%)
- Accuracy: +/- 1.5% of full Scale
- Response Time: T50 = 10 sec
- IR CO2 Detection
- 0 to 5% detection range
- Dual Beam Selective IR detection
- IP55 Enclosure Alloy Coated with Epoxy Paint
- -30C to +40C
- Response time: T90 = 70sec
ProDetec
Visit Website
Contact Details
Send Request-
Site-wide Integrated Radiological MonitoringSend Request
-
Coal Analysers - COALSCAN 2800Send Request
-
Alarm Transmission SystemsSend Request
-
Connect V5 Data Acquisition SystemSend Request
-
Single Gas, Personal Protection Monitor - ToxiRAE IISend Request
-
Flexible Foams / Austhane FF SeriesSend Request