17/12/2008 - 3 Day Basic Training Course
Our CRBasic 3 day training course offers users the chance to learn how to use and program Campbell data loggers in a hands on environment.
Our trainers will teach you software, hardware and programming components of Campbell loggers, and assist you with any questions you may have relating to your specific application.
DAY ONE
Introduction – DevConfig and Loggernet
• PakBus – How to check and set the address
• Creating new station profiles
• Connecting to data logger
• Setting the clock
• Send pre-written code to datalogger
• Monitor real-time data
• Graphing real-time data
• Download data from data logger
• Viewing Historical data files
• File Control
Hardware and Measurement Theory
• Wiring Panel
• Protection and Grounding
• No. of different inputs
• Single Ended Vs Differential
• Ground Vs Analogue Ground
• Integration Methods
Architecture
• Data Table Configuration – Public, Status, User Tables
• Individual Data Tables configured as circular buffers
• Sequential/Pipeline Program Mode
Internal Data Format
• IEEE4
• FP2
• Supported Data Types
Introduction to Programming – The first program
• Variable Declarations, Units & Aliasing
• Instruction groups
• Inserting and Deleting Instructions
• Instruction parameters
• Commenting
• Compiling
• Online Help
• Defining Data Tables
DAY TWO
Programming
• Practise programming for standard Meteorological & hydrological sensors
– 4-20mA Sensors
– Voltage Outputs
– Pulse/Frequency outputs
– Program to measure using a multiplexer
SDI – 12
• Explanation of SDI-12 instructions, wiring etc.
• Example with sensor
• Transparent mode
• SDI – 12 recorder and sensor instructions
Useful Programming Tools
• Datum Setting, Loops
• Control Operations using Boolean Variables
• Conditional Data Storage
DAY THREE
Loggernet Advanced features
• Scheduling
• Status/Log Tool
• CR1000 Status Table
Useful Tools
• Upgrading the Operating System
• Resetting data tables in the logger
• Resetting the data logger
Advanced Programming Exercises
• Pass data from one logger to another using Pakbus
• Complex conditions and multiple-parameter conditions
PakBus Network
• Setting up a simple network
• Radio modes
• PakBus Graph
• CR1000 as a router
• Neighbour Lists
User Applications
• Time to cover specific user applications including;
–Custom programming such as samplers, datums, etc.
–Custom sensors such as shaft encoders or any other specific product.
Price: $1020 +GST
Campbell Scientific Australia
Visit Website
Contact Details
Send Request