Macnaught Pty Ltd -
The TM100 turbine flowmeter has an excellent turndown ratio and is factory calibrated for precise measurement of low viscosity fluids.
The low pressure drop and high pressure rating allows the turbine meter range to be used in gravity, pump and inline applications.
Features of Turbine Fuel Meters
- available in LCD (TM100) and pulse (TM100P) versions
- high accuracy (better than ± 3 % of reading)
- excellent turndown ratio: 28:1
- robust aluminium construction and fully sealed against dust and water splash
- flow linearisation (display version)
- field programmable
- easy to read and operate resetable six-digit display with ability to show batch, reset total, non-reset total and rate of flow
- average battery life 2 years (2 x AAA alkaline)
- protective boot standard on LCD version – optional coloured boots available: red, blue, yellow, black and green.
- 10 year warranty
- 10 year spare parts availability
Specifications of Turbine Fuel Meters
- port Size: 1” BSPT / NPT
- wetted Materials: Aluminium, Tungsten, Ceramic, Derlin.
- maximum Pressure: 2070 kPa (300 psi, 20.6 bar)
- flow: 8 to 200 L/min (2.1 to 52.8 US gal/min)
- accuracy: better than ± 3 % of reading
- fluid compatibility: Diesel, kerosene, light oils (max. ISO22)
- TM100 LCD digits: 12 mm size and maximum of 6 digit display
- decimals: Selectable 0 to 3
- totals: Batch / Reset Total / Non Reset Total / Rate
- temperature range: 00C to 550C (320F to 1310F)
- TM100P Pulse operating Voltage: 12 to 30 V DC
- polarity protection: YES
- output: Open collector, maximum 1Watt peak (unfactored)
- electrical connection: PCB terminal strip 16 mm or 1/2” NPT conduit
- temperature range: 00C to 550C (320F to 1310F)
- K factor: 46.3ppL (175.26 pp USG) nominal at 100L/min
For further information about our Turbine Fuel Meters visit Macnaught at http://www.macnaught.com.au