Innovec Controls IDA4 Level Controller
FEATURES
Innovec is an ISO9001:2015 Quality Assured Company
TECHNICAL SPECIFICATIONS
Input Details
The instrument has a 16 bit bipolar differential input. To realise the accuracy a temperature compensated band gap reference is used in the ratio metric measurement system. The standard instrument is set for 4-20mA and 0-10VDC operation and can have units from 0 60,000. Other ranges are available. Please consult factory.
Outputs
Communication
Display
Decimal Point
Environmental Parameters
Connection Details
Terminal 1: Input common (-) |
Terminal 2: mA input (+) |
Terminal 3: voltage input (+) |
Terminal 4: 24VDC loop supply |
Terminal 5: not used |
Terminal 6: not used |
Terminal 7: not used |
Terminal 8: not used |
Terminal 9: not used |
Terminal 10: not used |
Terminal 11: not used |
Terminal 12: ma output (-) |
Terminal 13: ma output (+) |
Terminal 14: Voltage output (-) |
Terminal 15: Voltage output (+) |
Terminal 16: relay 1 common contact |
Terminal 17: relay 1 normally open contact |
Terminal 18: relay 1 normally closed contact |
Terminal 19: relay 2 common contact |
Terminal 20: relay 2 normally open contact |
Terminal 21: relay AL2 normally closed contact |
Terminal 22: relay AL3 common contact |
Terminal 23: relay AL3 normally open contact |
Terminal 24: relay AL3 normally closed contact |
Terminal 25: relay 4 common contact |
Terminal 26: relay AL4 normally open contact |
Terminal 27: relay AL4 normally closed contact |
Terminal 28: VAC active or VDC (+) supply |
Terminal 29: VAC neutral or VDC(-) supply |
Terminal 30: Ground supply |
Instrument Power Supply
Transducer Power Supply
Weight
Mounting Details
Configuration of the Instrument
Ordering Information
To contact Innovec Controls about Innovec Controls IDA4 Level Controller use Get a quote.
FEATURES
Innovec is an ISO9001:2015 Quality Assured Company
TECHNICAL SPECIFICATIONS
Input Details
The instrument has a 16 bit bipolar differential input. To realise the accuracy a temperature compensated band gap reference is used in the ratio metric measurement system. The standard instrument is set for 4-20mA and 0-10VDC operation and can have units from 0 60,000. Other ranges are available. Please consult factory.
Outputs
Communication
Display
Decimal Point
Environmental Parameters
Connection Details
Terminal 1: Input common (-) |
Terminal 2: mA input (+) |
Terminal 3: voltage input (+) |
Terminal 4: 24VDC loop supply |
Terminal 5: not used |
Terminal 6: not used |
Terminal 7: not used |
Terminal 8: not used |
Terminal 9: not used |
Terminal 10: not used |
Terminal 11: not used |
Terminal 12: ma output (-) |
Terminal 13: ma output (+) |
Terminal 14: Voltage output (-) |
Terminal 15: Voltage output (+) |
Terminal 16: relay 1 common contact |
Terminal 17: relay 1 normally open contact |
Terminal 18: relay 1 normally closed contact |
Terminal 19: relay 2 common contact |
Terminal 20: relay 2 normally open contact |
Terminal 21: relay AL2 normally closed contact |
Terminal 22: relay AL3 common contact |
Terminal 23: relay AL3 normally open contact |
Terminal 24: relay AL3 normally closed contact |
Terminal 25: relay 4 common contact |
Terminal 26: relay AL4 normally open contact |
Terminal 27: relay AL4 normally closed contact |
Terminal 28: VAC active or VDC (+) supply |
Terminal 29: VAC neutral or VDC(-) supply |
Terminal 30: Ground supply |
Instrument Power Supply
Transducer Power Supply
Weight
Mounting Details
Configuration of the Instrument
Ordering Information
To contact Innovec Controls about Innovec Controls IDA4 Level Controller use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product