Australia's #1 industrial directory for equipment & suppliers

Flow Meter - FM1-CA

Supplier: E-T-A

The micro controller operated Flow Meter FM1-CA for gases such as air, oxygen nitrogen, carbon dioxide is particularly suited to consumption measurement and leakage detection in compressed air systems.

Price Guide: POA

Flow Meter - FM1-CA suitable for use with calorimetric monitoring heads.

Caution: CO2 can only be measured with sensor adapter TP-01...TP-04.

The sensor must not ice up.

  • Voltage rating of Flow Meter - FM1-CA:
    • DC 24 V
  • Input voltage of Flow Meter - FM1-CA:
    • DC 24 V (19...32 V)
  • Media of Flow Meter - FM1-CA:
    • gases
      • air
      • compressed air
      • oxygen O2
      • nitrogen N2
      • carbon dioxide
  • Measuring range of Flow Meter - FM1-CA:
    • air: with CSP-monitoring head sensor adapter TP
    • TP-01 0- 50 ( 70) Nm3/h
    • TP-02 0- 77 (109) Nm3/h
    • TP-03 0-120 (170) Nm3/h
    • TP-04 0-197 (280) Nm3/h
    • TP-05 0-308 (439) Nm3/h
    • TP-06 0-480 (685) Nm3/h
  • Outputs/interfaces of Flow Meter - FM1-CA:
    • analogue outputs:
    • 0/4-20 mA or 0/2-10 V or 0/1-5 V
    • signal outputs: relay or transistor outputs
  • Design of Flow Meter - FM1-CA:
    • rail-mounted version
  • Process connection:
    • calorimetric heads (CST, CSF, CSP)
  • Materials of monitoring head:
    • Stainless steel 1.4571/AISI 316 Ti or Hastelloy alloy
  • Temperature range electronic control unit:
    • from +10 °C to +50 °C
  • Temperature range monitoring head:
    • from -40 °C to +130 °C
  • Protection class electronic control unit:
    • IP20
  • Protection class monitoring head:
    • IP67 (connector)