Series 6103 Ozone Transfer Standard

Supplier: Lear Siegler Australasia

The EnvironicsĀ® Series 6103 Ozone Transfer Standard / Multi-Gas Calibrator is a computer controlled, state-of-the-art instrument for dynamic calibration of ambient air analyzers.

CONTACT THIS SUPPLIER TO FIND OUT MORE

The Series 6103 automatically performs zero, precision, span and multi-point calibrations using NO, NO2, SO2, CO, 03, hydrocarbons and other gases of interest. The 6103 meets all U.S. Environmental Protection Agency requirements.

The Series 6103 consists of a single chassis supporting 2 thermal mass flow controllers, an ozone generation module, photometer, 3 port glass output manifold, mixing chamber, a reaction chamber for gas phase titration, and control electronics.

Commands are entered from the front panel and displayed on a backlit 4 line by 20 character liquid crystal display. The instrument may also be remotely operated using contact closures or the RS-232 serial data interface, both are standard in the Series 6103.

The mass flow controllers are factory calibrated at 11 points to a NIST (National Institute of Standards and Technology) traceable primary standard. The calibration data consists of a comparison of desired versus actual flow over the full dynamic range of the instrument with linear interpolation between points. Calibration data is stored in non-volatile memory and may be updated by the user with a suitable standard.

The internal ultra-violet (UV) based ozone generator is temperature controlled and includes a precision photo-optical feedback circuit to compensate for lamp aging effects providing stable ozone generation. The ozone generator is factory calibrated using a NIST traceable photometer standard.


FEATURES AND BENEFITS of Series 6103 Ozone Transfer Standard:
User-friendly interactive software with plain language prompts is simple to use, reducing technician training time and virtually eliminating error.

Automatic calculation of dilution and span gas flows based on commanded concentration eliminates the need for manual computation and allows rapid transition from point to point.
Internally-stored mass flow controller calibration data improves accuracy by as much as a factor of ten and simplifies field recalibration. Mass flow controllers are factory calibrated at 11 points.

Internally-stored ozone generator calibration data insures linear, repeatable ozone generation without photometer control. Ozone generator performance meets U.S. EPA criteria for ozone transfer standards. The ozone generator is factory calibrated at 3 points. Up to 11 points are available.

Ozone generator pressure compensation ensures repeatable and stable ozone generation at pressures other than that at which it was originally calibrated. This is only important when the system is being used without the photometer closed-loop control.

Photometer measures the actual amount of ozone generated, and corrects for errors, using PID closed-loop control.

The photometer allows an external source of ozone to be analyzed and displayed on the screen. The ozone is connected to a separate sample port. This allows for simultaneous gas blending while monitoring an external source of ozone.

The automated leak test function uses a pressure decay test with internal absolute pressure transducers. The complete system plumbing path is tested to better than 1 sccm leak.