Fluke 376 FC True-RMS Clamp Meter
Fluke - 376 FC True-RMS Clamp Meter
Offers accurate voltage and current measurements with advanced features like wireless connectivity. Ideal for industrial and electrical professionals, it ensures efficient troubleshooting and diagnostics in complex systems.
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
Key Features
- Measures AC/DC current with included iFlex current probe
- VFD low pass filter for accurate measurements of non-linear signals
- Remotely log, trend and monitor to pinpoint intermittent faults
- Inrush measurement to filter out noise and capture starting current
Find the cause of difficult problems
The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
Measure:
- Voltage to 1000 V AC or DC
- Resistance to 60 kΩ with continuity detection
- Min, max, average, and inrush recording to capture variations automatically
- 500 mV DC measurement range to interface with other accessories
- 1000 μF capacitance measurement
Work safely and conveniently
The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.
The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:
- Expands the measurement range to 2500 A AC
- Allows frequency measurement to 500 Hz with body jaw and iFlex
Specifications: Fluke 376 FC True-RMS Clamp Meter
| General Specifications | ||
| AC Current via Jaw | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |
| 2.5% ±5 digits (100-500 Hz) | ||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |
| 2.5 @ 600 A | ||
| Add 2% for C.F. >2 | ||
| AC Current via Flexible Current Probe | ||
| Range | 2500 A | |
| Resolution | 0.1 A (≤ 600 A) | |
| 1 A (≤ 2500 A) | ||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |
| Crest Factor (50/60Hz) | 3.0 at 1100 A | |
| 2.5 at 1400 A | ||
| 1.42 at 2500 A | ||
| Add 2% for C.F. > 2 | ||
| Position Sensitivity | ||
![]() |
||
| i2500-10 Flex | i2500-18 Flex | |
| A | ||
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| Error | ±0.5 % | ±0.5 % |
| B | ||
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| Error | ±1.0 % | ±1.0 % |
| C | ||
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| Error | ±2.0 % | ±2.0 % |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||
| DC Current | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits | |
| AC Voltage | ||
| Range | 1000 V | |
| Resolution | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | |
| DC Voltage | ||
| Range | 1000 V | |
| Resolution | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| Accuracy | 1% ±5 digits | |
| mV dc | ||
| Range | 500.0 mV | |
| Resolution | 0.1 mV | |
| Accuracy | 1% ±5 digits | |
| Frequency via Jaw | ||
| Range | 5.0 Hz to 500.0 Hz | |
| Resolution | 0.1 Hz | |
| Accuracy | 0.5% ±5 digits | |
| Trigger level | 5 Hz to 10 Hz, ≥10 A | |
| 10 Hz to 100 Hz, ≥5 A | ||
| 100 Hz to 500 Hz, ≥10 A | ||
| Frequency via Flexible Current Probe | ||
| Range | 5.0 Hz to 500.0 Hz | |
| Resolution | 0.1 Hz | |
| Accuracy | 0.5% ±5 digits | |
| Trigger level | 5 Hz to 20 Hz, ≥25 A | |
| 20 Hz to 100 Hz, ≥20 A | ||
| 100 Hz to 500 Hz, ≥25 A | ||
| Resistance | ||
| Range | 60 kΩ | |
| Resolution | 0.1 Ω (≤600 Ω) | |
| 1 Ω (≤6000 Ω) | ||
| 10 Ω (≤60 kΩ) | ||
| Accuracy | 1% ±5 digits | |
| Capacitance | ||
| Range | 1000 μF | |
| Resolution | 0.1 μF (≤ 100 μF) | |
| 1 μ F (≤ 1000 μF) | ||
| Accuracy | 1% ±4 digits | |
| Mechanical Specifications | ||
| Maximum voltage between any terminal and earth ground | 1000 V | |
| Batteries | 2 AA, NEDA 15A, IEC LR6 | |
| Operating temperature | -10 °C to +50 °C | |
| Storage temperature | -40 °C to +60 °C | |
| Operating humidity - non-condensing (< 10°C) |
≤90% RH (at 10 °C to 30 °C) | |
| ≤75% RH (at 30 °C to 40 °C) | ||
| ≤45% RH (at 40 °C to 50 °C) | ||
| Operating altitude | 2000 m | |
| Storage altitude | 12,000 m | |
| Size (L x W x H) | 249 x 85 x 45 mm | |
| Weight | 395 g | |
| Jaw opening | 34 mm | |
| Flexible current probe diameter | 7.5 mm | |
| Flexible current probe cable length (head to electronics connector) |
1.8 m | |
| Safety | IEC 61010-1, Pollution Degree 2 | |
| IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||
| IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | ||
| IP rating | IEC 60529: IP30, non-operating | |
| Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE | |
| Electromagnetic Compatibility (EMC) | ||
| International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 | |
| CISPR 11: Group 1, Class A | ||
| Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | ||
| Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. | ||
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
| Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
| Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C | |
Models: Fluke 376 FC True-RMS Clamp Meter
Includes:
- Fluke 376 FC True-RMS Clamp Meter with iFlex
- 18-inch iFlex® Flexible Current Probe
- TPAK magnetic hanging strap
- TL75 Test Leads
- Two AA batteries (Installed)
- Soft carrying case
- Coated instruction card
- Safety information sheet
To contact Fluke Australia about Fluke 376 FC True-RMS Clamp Meter use Get a quote.
The Fluke 376 FC True-rms Clamp Meter with iFlex is the most advanced troubleshooting tool for industrial and commercial electricians. The 376 is part of the Fluke Connect family of wireless test tools that enable you to log, trend and monitor measurements while remaining safely away from the arc flash zone through Bluetooth connectivity.
Key Features
- Measures AC/DC current with included iFlex current probe
- VFD low pass filter for accurate measurements of non-linear signals
- Remotely log, trend and monitor to pinpoint intermittent faults
- Inrush measurement to filter out noise and capture starting current
Find the cause of difficult problems
The 376 FC clamp meter uses an integrated low-pass filter for accurate measurements of non-linear signals, such as adjustable speed drives, electronic ballasts and other non-linear loads. The clamp also uses proprietary inrush measurement technology to filter out noise and capture motor starting current exactly as the circuit protection sees it.
Measure:
- Voltage to 1000 V AC or DC
- Resistance to 60 kΩ with continuity detection
- Min, max, average, and inrush recording to capture variations automatically
- 500 mV DC measurement range to interface with other accessories
- 1000 μF capacitance measurement
Work safely and conveniently
The 376 FC clamp carries a CAT III 1000 V, CAT IV 600 V safety rating, designed to offer you the highest possible protection in a test tool.
The included iFlex flexible current probe provides easier access to large conductors in tight spaces. The flexible probe:
- Expands the measurement range to 2500 A AC
- Allows frequency measurement to 500 Hz with body jaw and iFlex
Specifications: Fluke 376 FC True-RMS Clamp Meter
| General Specifications | ||
| AC Current via Jaw | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits (10 Hz to 100 Hz) | |
| 2.5% ±5 digits (100-500 Hz) | ||
| Crest Factor (50 Hz/60 Hz) | 3 @ 500 A | |
| 2.5 @ 600 A | ||
| Add 2% for C.F. >2 | ||
| AC Current via Flexible Current Probe | ||
| Range | 2500 A | |
| Resolution | 0.1 A (≤ 600 A) | |
| 1 A (≤ 2500 A) | ||
| Accuracy | 3% ±5 digits (5 – 500 Hz) | |
| Crest Factor (50/60Hz) | 3.0 at 1100 A | |
| 2.5 at 1400 A | ||
| 1.42 at 2500 A | ||
| Add 2% for C.F. > 2 | ||
| Position Sensitivity | ||
![]() |
||
| i2500-10 Flex | i2500-18 Flex | |
| A | ||
| Distance from Optimum | 0.5 in (12.7 mm) | 1.4 in (35.6 mm) |
| Error | ±0.5 % | ±0.5 % |
| B | ||
| Distance from Optimum | 0.8 in (20.3 mm) | 2.0 in (50.8 mm) |
| Error | ±1.0 % | ±1.0 % |
| C | ||
| Distance from Optimum | 1.4 in (35.6 mm) | 2.5 in (63.5 mm) |
| Error | ±2.0 % | ±2.0 % |
| Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range. | ||
| DC Current | ||
| Range | 999.9 A | |
| Resolution | 0.1 A | |
| Accuracy | 2% ±5 digits | |
| AC Voltage | ||
| Range | 1000 V | |
| Resolution | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| Accuracy | 1% ±5 digits (20 Hz to 500 Hz) | |
| DC Voltage | ||
| Range | 1000 V | |
| Resolution | 0.1 V (≤600.0 V) | |
| 1 V (≤1000 V) | ||
| Accuracy | 1% ±5 digits | |
| mV dc | ||
| Range | 500.0 mV | |
| Resolution | 0.1 mV | |
| Accuracy | 1% ±5 digits | |
| Frequency via Jaw | ||
| Range | 5.0 Hz to 500.0 Hz | |
| Resolution | 0.1 Hz | |
| Accuracy | 0.5% ±5 digits | |
| Trigger level | 5 Hz to 10 Hz, ≥10 A | |
| 10 Hz to 100 Hz, ≥5 A | ||
| 100 Hz to 500 Hz, ≥10 A | ||
| Frequency via Flexible Current Probe | ||
| Range | 5.0 Hz to 500.0 Hz | |
| Resolution | 0.1 Hz | |
| Accuracy | 0.5% ±5 digits | |
| Trigger level | 5 Hz to 20 Hz, ≥25 A | |
| 20 Hz to 100 Hz, ≥20 A | ||
| 100 Hz to 500 Hz, ≥25 A | ||
| Resistance | ||
| Range | 60 kΩ | |
| Resolution | 0.1 Ω (≤600 Ω) | |
| 1 Ω (≤6000 Ω) | ||
| 10 Ω (≤60 kΩ) | ||
| Accuracy | 1% ±5 digits | |
| Capacitance | ||
| Range | 1000 μF | |
| Resolution | 0.1 μF (≤ 100 μF) | |
| 1 μ F (≤ 1000 μF) | ||
| Accuracy | 1% ±4 digits | |
| Mechanical Specifications | ||
| Maximum voltage between any terminal and earth ground | 1000 V | |
| Batteries | 2 AA, NEDA 15A, IEC LR6 | |
| Operating temperature | -10 °C to +50 °C | |
| Storage temperature | -40 °C to +60 °C | |
| Operating humidity - non-condensing (< 10°C) |
≤90% RH (at 10 °C to 30 °C) | |
| ≤75% RH (at 30 °C to 40 °C) | ||
| ≤45% RH (at 40 °C to 50 °C) | ||
| Operating altitude | 2000 m | |
| Storage altitude | 12,000 m | |
| Size (L x W x H) | 249 x 85 x 45 mm | |
| Weight | 395 g | |
| Jaw opening | 34 mm | |
| Flexible current probe diameter | 7.5 mm | |
| Flexible current probe cable length (head to electronics connector) |
1.8 m | |
| Safety | IEC 61010-1, Pollution Degree 2 | |
| IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V | ||
| IEC 61010-2-033:CAT III 1000 V / CAT IV 600 V | ||
| IP rating | IEC 60529: IP30, non-operating | |
| Radio Frequency Certification FCC ID | T68-FBLE IC:6627A-FBLE | |
| Electromagnetic Compatibility (EMC) | ||
| International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 | |
| CISPR 11: Group 1, Class A | ||
| Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | ||
| Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. | ||
| Korea (KCC) | Class A Equipment (Industrial Broadcasting & Communication Equipment) | |
| Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | ||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
| Temperature coefficients | Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C | |
Models: Fluke 376 FC True-RMS Clamp Meter
Includes:
- Fluke 376 FC True-RMS Clamp Meter with iFlex
- 18-inch iFlex® Flexible Current Probe
- TPAK magnetic hanging strap
- TL75 Test Leads
- Two AA batteries (Installed)
- Soft carrying case
- Coated instruction card
- Safety information sheet
To contact Fluke Australia about Fluke 376 FC True-RMS Clamp Meter use Get a quote.
The Fluke 376 FC True-RMS clamp meter set includes an iFlex probe and magnetic TPAK strap, and measures AC and DC current and voltage. Bluetooth connectivity lets electricians log, trend and monitor readings remotely to pinpoint intermittent faults while staying away from the arc flash zone. Industrial and commercial electricians can use the probe to reach large conductors in tight spaces.
- VFD low-pass filter measures non-linear signals accurately
- CAT III 1000 V / CAT IV 600 V safety rating
- AC and DC voltage range up to 1000 V
- iFlex probe extends AC current measurement to 2500 A
- Also included: TL75 leads, 2 AA batteries, soft case, instruction card, safety sheet
Source: listing by Fluke Australia on IndustrySearch
· Updated 6 Nov 2026
Supplier document: Fluke 370 FC Series True-rms Wireless AC DC Clamp Meters (PDF)
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Fluke Australia on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Leaks + Conveyors + Partial discharge - Fluke ii915 Acoustic Imager
Locate air, gas and vacuum leaks - Industrial Acoustic Imager - ii905
Fluke's Most Affordable Leak Detector - ii500 Acoustic Imager
TiX875 & TiX885 Thermal Camera with GPS
TiX580 Infrared Camera
Ti480U, Ti401U, & Ti300U Ultra Series Infrared Thermal Cameras
TiX1060 Extreme High Resolution Thermal Camera
Ti480 PRO Infrared Camera
TiS75+ Thermal Camera
TiS55+ Thermal Camera
TiS60+ Thermal Camera
TiS20+ / TiS20+ MAX Thermal Imaging Camera
Compact PTi120 Pocket Thermal Camera
SmartView R&D Thermal Imaging Software
1770 Series Three-Phase Power Quality Analyzers
Power Quality Tool | Norma 6000 Series Portable Power Analyzers
Power Quality Loggers | 1732 & 1734 Three-Phase Electrical Logger
1742, 1746 and 1748 Three-Phase Power Quality Loggers
190 Series III ScopeMeter® Test Tools
MDA-550 Series III Motor Drive Analyzer
Clamp Meter | CM-6146 | 1000Amp
Clamp Meters | 1000A DCA/ACA
Leakage Clamp TRMS Meter with Power Functions | MD 9270
Non Contact Voltage Clamp Meter | 377 FC
Handheld Clamp Meter | U1211A
Clamp Meter | 770-1
Clamp Meter | 770-2
770-3 Series Clamp Meter
Clamp Meter | AccuTip | CM44 | True RMS
Power Clamp Meter | CM82 | True RMS
Power Clamp Meter (Wireless) | CM83 | True RMS
Power Clamp Meter (Wireless) | CM85 | True RMS
Clamp Meters | 355 True RMS 2000 A
325 True RMS Clamp Meter
393 FC CAT III 1500 V True-rms Clamp Meter with iFlex
Non-Contact Voltage True-rms AC/DC Clamp Meter | Fluke 378 FC w/ iFlex
Non-Contact Voltage True-rms AC/DC Clamp Meter | Fluke 377 FC w/ iFlex
Digital Clamp Meter with Inrush Function - AC/DC 1000A True RMS | 514
True RMS AC/DC Clamp Meter IP54 | Model 205
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product