Anton Paar - Automatic Kinematic Viscometer SVM 1001 Simple Fill
Kinematic viscometers SVM 1001 determines kinematic and dynamic viscosity & density from a single run, Enjoy all the benefits of ASTM D7042 and report in both D7042 as well as D445 with the integrated ASTM-defined bias corrections.
Key Features
- Fill sample or solvent directly from the container with Simple Fill funnel: No pipette or syringe required with SVM 1001 Simple Fill and SVM 1101 Simple Fill
- Benefit from an intuitive user interface and compact design (battery option available)
- Select your temperature between 15 °C and 100 °CGet results digitally in less than five minutes with just 1.5 mL of sample: no more stopwatch or manual calculations
- Use one unbreakable cell instead of 12 Ubbelohde viscometers
Save time with our automatic kinematic viscometers
- 150 % higher throughput compared to manual methods
- Faster results help avoid out-of-spec production
- Temperature equilibration in one minute or less
- Fill sample or solvent directly from the container with Simple Fill funnel: No pipette or syringe required with SVM 1001 Simple Fill and SVM 1101 Simple Fill
Experience error-free digital data handling
- Automatic calculations and digital data recording and storage for error-free measurements and traceability
- Data export from device to a PC or USB drive
- One-click data access from your automatic kinematic viscometer
Improve safety for lab and operator
- A metal measuring cell makes glass breakage a thing of the past
- Built-in Peltier thermostatting for fast temperature control
- Reduced exposure to hazardous solvents or flammable bath liquids
Minimal sample, solvent, and energy consumption
- Analysis with just 5 mL of sample and 6 mL of solvent
- Low energy consumption – 50 W to get started
- Minimal downtime: 2-minute cleaning, 30-minute downtime during maintenance
- Quality control documentation efforts reduced by 50 %
- No external PC or software needed
Stay compliant and benefit from bias correction
- ASTM D7042 is referenced in ASTM, SAE, ISO, IP, EN, DIN, DEFSTAN, ML, GB, GOST, and other standards as an accepted alternative to D445
- With the ASTM bias correction, you can report results in both D7042 and D445
- Complies with ASTM D396, D975, D1655, D3699, D6158, D6823, D7467, and other standards
- ASTM D4052 density measurement included (SVM 1101 Simple Fill)
Technical specifications
| SVM 1001 | SVM 1001 Simple Fill |
SVM 1101 Simple Fill |
SVM 2001 | SVM 3001 | SVM 3001 Cold Properties |
SVM 4001 | |
| Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT 516302 (B1), CN105628550 | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) AT516302 (B1), CN105628550 | |||
| Test methods | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 | ASTM D4052, ISO 12185 | ASTM D7042, D445 bias-corrected, ISO 23581, EN 16896 ASTM D4052 (optional) |
ASTM D7042, D445 bias-corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 | ASTM D7042, D445 bias -corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 ASTM D2386 equiv. or better ASTM D2500 equiv. or better |
ASTM D7042, D445 bias-corrected, ISO 23581, EN 16896, ASTM D4052, ISO 12185 | |
| Measuring Range | |||||||
| Viscosity | 0.3 mm²/s to 5,000 mm²/s | 0.3 mm²/s to 1,000 mm²/s | 0.2 mm²/s to 30,000 mm²/s* | ||||
| Density | - | - | 0 g/cm³ to 3 g/cm³ | 0 g/cm³ to 3 g/cm³ | |||
| Temperature | +15 °C to +100 °C (one temperature, second temperature optional) | +15 °C to +100 °C | +15 °C to +100 °C | -60 °C to +135 °C | -60 °C to +100 °C | +15 °C to +100°C | |
| Precision | |||||||
| Viscosity repeatability** and reproducibility** | 0.1 % and 0.35 % | 0.2 % and 0.7 % | 0.1 % and 0.35 % | ||||
| Density repeatability** and reproducibility** |
- | - | 0.00005 g/cm³ and 0.0001 g/cm³ | 0.0002 g/cm³ (0.00005 g/cm² with ASTM D4052 option) and 0.0005 g/cm³ (0.0001 g/cm² with ASTM D4052 option) |
0.00005 g/cm³ and 0.0001 g/cm³ | ||
| Cloud/freeze point repeatability** and reproducibility** |
- | - | - | - | - | <0.5 °C / <0.5 °C and <2.5 °C / <1.3 °C |
- |
| Temperature repeatability | 0.005 °C | 0.005 °C | |||||
| Temperature reproducibility | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | |||
| Performance | |||||||
| Sample volume min. / typical | 1.5 mL / 5 mL | 3.5 mL / 8 mL | 1.5 mL / 5 mL | 2.5 mL / 6 mL | |||
| Solvent volume min. / typical | 1.5 mL / 6 mL | 5 mL / 10 mL | 1.5 mL / 6 mL | 2.5 mL / 10 mL | |||
| Max. sample throughput | 37 samples per hour | 21 samples per hour | 33 samples per hour | 30 samples per hour | 24 samples per hour | ||
| Features | |||||||
| Optional upgrades | Second temperature | - | Automatic VI determination ASTM D4052-compliant density measurement | Chemical upgrade kit | - | - | |
| Modularity with Abbemat refractometers 300/500, 350/550, 450/650 | |||||||
| Accessories | Magnetic particle trap (MPT) | - | - | Magnetic particle trap (MPT), hot filling attachment (HFA) | Magnetic particle trap (MPT) | ||
| Automation | - | Integrated Simple Fill Filling Device | Optional sample changer + High-Throughput Platform HTV |
Optional sample changer + High-Throughput Platform HTV | Optional sample changer + High-Throughput Platform HTV |
||
| Technical Data | |||||||
| Data memory | 1,000 measurement results | ||||||
| HID (Human Interface Device) | 7" touchscreen | 10.4" touchscreen, optional keyboard, mouse, and 2D bar code reader | |||||
| Interfaces | 4 x USB (3 x A, 1 xB) | 4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 X CAN bus, 1 x RS-232, 1 x VGA | |||||
| Power supply | At instrument: DC, 24 V /3A, AC adapter 90 VAC to 264 VAC, 47 Hat to 63 Hz, < 75W | AC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max. | |||||
| Ambient conditions | 15 °C to 35 °C, max. 80 % r.h. non-condensing | ||||||
| Net weight in kg | 5.6 kg | 6.6 kg | 15.9 kg | 17.6 kg | 18.0 kg | 17.8 kg | |
| Dimensions (W x D x H) |
26.5 cm x 36.5 cm x 18 cm | 33 cm x 36.5 cm x 20.5 cm | 33 cm x 51 cm x 23.1 cm | ||||
| Trademarks | SVM (13411996), FillingCheck (6834725), Abbemat (1084545) | ||||||
*Viscosity range with chemical upgrade kit from 1 mPa·s to 10,000 mPa·s.
**Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standard
To contact Anton Paar Australia about Anton Paar Automatic Kinematic Viscometer SVM 1001 Simple Fill use Get a quote.
Key Features
- Fill sample or solvent directly from the container with Simple Fill funnel: No pipette or syringe required with SVM 1001 Simple Fill and SVM 1101 Simple Fill
- Benefit from an intuitive user interface and compact design (battery option available)
- Select your temperature between 15 °C and 100 °CGet results digitally in less than five minutes with just 1.5 mL of sample: no more stopwatch or manual calculations
- Use one unbreakable cell instead of 12 Ubbelohde viscometers
Save time with our automatic kinematic viscometers
- 150 % higher throughput compared to manual methods
- Faster results help avoid out-of-spec production
- Temperature equilibration in one minute or less
- Fill sample or solvent directly from the container with Simple Fill funnel: No pipette or syringe required with SVM 1001 Simple Fill and SVM 1101 Simple Fill
Experience error-free digital data handling
- Automatic calculations and digital data recording and storage for error-free measurements and traceability
- Data export from device to a PC or USB drive
- One-click data access from your automatic kinematic viscometer
Improve safety for lab and operator
- A metal measuring cell makes glass breakage a thing of the past
- Built-in Peltier thermostatting for fast temperature control
- Reduced exposure to hazardous solvents or flammable bath liquids
Minimal sample, solvent, and energy consumption
- Analysis with just 5 mL of sample and 6 mL of solvent
- Low energy consumption – 50 W to get started
- Minimal downtime: 2-minute cleaning, 30-minute downtime during maintenance
- Quality control documentation efforts reduced by 50 %
- No external PC or software needed
Stay compliant and benefit from bias correction
- ASTM D7042 is referenced in ASTM, SAE, ISO, IP, EN, DIN, DEFSTAN, ML, GB, GOST, and other standards as an accepted alternative to D445
- With the ASTM bias correction, you can report results in both D7042 and D445
- Complies with ASTM D396, D975, D1655, D3699, D6158, D6823, D7467, and other standards
- ASTM D4052 density measurement included (SVM 1101 Simple Fill)
Technical specifications
| SVM 1001 | SVM 1001 Simple Fill |
SVM 1101 Simple Fill |
SVM 2001 | SVM 3001 | SVM 3001 Cold Properties |
SVM 4001 | |
| Patents | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1), AT 516302 (B1), CN105628550 | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) | AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) AT516302 (B1), CN105628550 | |||
| Test methods | ASTM D7042, D445 bias corrected, ISO 23581, EN 16896 | ASTM D4052, ISO 12185 | ASTM D7042, D445 bias-corrected, ISO 23581, EN 16896 ASTM D4052 (optional) |
ASTM D7042, D445 bias-corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 | ASTM D7042, D445 bias -corrected, ISO 23581, EN 16896 ASTM D4052, ISO 12185 ASTM D2386 equiv. or better ASTM D2500 equiv. or better |
ASTM D7042, D445 bias-corrected, ISO 23581, EN 16896, ASTM D4052, ISO 12185 | |
| Measuring Range | |||||||
| Viscosity | 0.3 mm²/s to 5,000 mm²/s | 0.3 mm²/s to 1,000 mm²/s | 0.2 mm²/s to 30,000 mm²/s* | ||||
| Density | - | - | 0 g/cm³ to 3 g/cm³ | 0 g/cm³ to 3 g/cm³ | |||
| Temperature | +15 °C to +100 °C (one temperature, second temperature optional) | +15 °C to +100 °C | +15 °C to +100 °C | -60 °C to +135 °C | -60 °C to +100 °C | +15 °C to +100°C | |
| Precision | |||||||
| Viscosity repeatability** and reproducibility** | 0.1 % and 0.35 % | 0.2 % and 0.7 % | 0.1 % and 0.35 % | ||||
| Density repeatability** and reproducibility** |
- | - | 0.00005 g/cm³ and 0.0001 g/cm³ | 0.0002 g/cm³ (0.00005 g/cm² with ASTM D4052 option) and 0.0005 g/cm³ (0.0001 g/cm² with ASTM D4052 option) |
0.00005 g/cm³ and 0.0001 g/cm³ | ||
| Cloud/freeze point repeatability** and reproducibility** |
- | - | - | - | - | <0.5 °C / <0.5 °C and <2.5 °C / <1.3 °C |
- |
| Temperature repeatability | 0.005 °C | 0.005 °C | |||||
| Temperature reproducibility | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | 0.03 °C from +15 °C to +100 °C | |||
| Performance | |||||||
| Sample volume min. / typical | 1.5 mL / 5 mL | 3.5 mL / 8 mL | 1.5 mL / 5 mL | 2.5 mL / 6 mL | |||
| Solvent volume min. / typical | 1.5 mL / 6 mL | 5 mL / 10 mL | 1.5 mL / 6 mL | 2.5 mL / 10 mL | |||
| Max. sample throughput | 37 samples per hour | 21 samples per hour | 33 samples per hour | 30 samples per hour | 24 samples per hour | ||
| Features | |||||||
| Optional upgrades | Second temperature | - | Automatic VI determination ASTM D4052-compliant density measurement | Chemical upgrade kit | - | - | |
| Modularity with Abbemat refractometers 300/500, 350/550, 450/650 | |||||||
| Accessories | Magnetic particle trap (MPT) | - | - | Magnetic particle trap (MPT), hot filling attachment (HFA) | Magnetic particle trap (MPT) | ||
| Automation | - | Integrated Simple Fill Filling Device | Optional sample changer + High-Throughput Platform HTV |
Optional sample changer + High-Throughput Platform HTV | Optional sample changer + High-Throughput Platform HTV |
||
| Technical Data | |||||||
| Data memory | 1,000 measurement results | ||||||
| HID (Human Interface Device) | 7" touchscreen | 10.4" touchscreen, optional keyboard, mouse, and 2D bar code reader | |||||
| Interfaces | 4 x USB (3 x A, 1 xB) | 4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 X CAN bus, 1 x RS-232, 1 x VGA | |||||
| Power supply | At instrument: DC, 24 V /3A, AC adapter 90 VAC to 264 VAC, 47 Hat to 63 Hz, < 75W | AC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max. | |||||
| Ambient conditions | 15 °C to 35 °C, max. 80 % r.h. non-condensing | ||||||
| Net weight in kg | 5.6 kg | 6.6 kg | 15.9 kg | 17.6 kg | 18.0 kg | 17.8 kg | |
| Dimensions (W x D x H) |
26.5 cm x 36.5 cm x 18 cm | 33 cm x 36.5 cm x 20.5 cm | 33 cm x 51 cm x 23.1 cm | ||||
| Trademarks | SVM (13411996), FillingCheck (6834725), Abbemat (1084545) | ||||||
*Viscosity range with chemical upgrade kit from 1 mPa·s to 10,000 mPa·s.
**Attested at the points of the works adjustment or at calibration correction points, not including the uncertainty of the standard
To contact Anton Paar Australia about Anton Paar Automatic Kinematic Viscometer SVM 1001 Simple Fill use Get a quote.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Rotational Viscometer ViscoQC 100
Rotational Viscometer ViscoQC 300
Rotational Viscometer ViscoQC 100/300 with Motorized Stand Heli-Plus
Rotational Viscometer ViscoQC 100 with PTD 80 (+15 °C to +80 °C)
Rotational Viscometer ViscoQC 300 + PTD 100 Cone/Plate 0 °C to 100 °C
Rotational Viscometer ViscoQC 300 + PTD 175 (-45 °C to +175 °C)
Rotational Viscometer ViscoQC 300 + ETD 300 (+25 °C to +300 °C)
Compact Digital Refractometers - Abbemat
Litesizer DIF | Laser Diffraction Particle Size Analyzer
Litesizer DLS Series | Dynamic Light Scattering Instrument
Autosorb Series | High Vacuum Physisorption Analyzer
Nova Series | Surface Area and Pore Size Analyzers
MCR 702e MultiDrive | High-end Modular Compact Rheometer
RheolabQC | Rotational Rheometer
Extruder/Extrusiograph 30/25 and 30/32 | Single Screw Extruder
Extruder / Extrusiograph 19/25 and 19/32 | Single Screw Extruders
Twin Screw Compounder TSC 42/6
Mini-Compounder KETSE 12/36 D
Single Screw Extruders | Measuring Extruders and Extrusiograph
MetaStation | Modular Torque Rheometer Drives
SV10-100 SineWave Vibro Viscometer
Rheomat R180 Portable Viscometer | Test and Tag
Cone & Plate Viscometers
Digital Viscometer
Rotothinner Viscometer
Viscometer | Viskomat NT
Viscometer | Viskomat XL
Process Viscometers | ViscoTron Sensor - VP-1000 Series
Process Viscometers | ViscoTron Sensor - VP-3000 Series
Rotational Viscometer ViscoQC 100 with PTD 80 (+15 °C to +80 °C)
Rotational Viscometer ViscoQC 300 + PTD 100 Cone/Plate 0 °C to 100 °C
Rotational Viscometer ViscoQC 300 + PTD 175 (-45 °C to +175 °C)
Rotational Viscometer ViscoQC 100/300 with Motorized Stand Heli-Plus
Rotational Viscometer ViscoQC 300 + ETD 300 (+25 °C to +300 °C)
Rotational Viscometer ViscoQC 100
Rotational Viscometer ViscoQC 300
Viscometer | Anton Paar Lab Favourites Bundle #5 - for Paste & Liquids
Rheometer & Viscometer | Lab Favourites Bundle #1 | Paste & Liquids
ViscoQuick | Universal Torque Viscometer
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product