Miro Power Quality Analyser PQ45
Miro Power Quality Analyser PQ45
The Miro PQ45 is a Class A portable power quality analyser that can measure a comprehensive range of power quality parameters. With it’s IP66 rating, the Miro PQA can be installed outdoor in the most severe weather conditions.
The PQ45 has the highest safety rating of all portable power quality analysers – CAT IV 600V. The fourth voltage channel on the PQ45 allows for ground-neutral voltage measurements. The integrated remote communication module (optional) allows the user to access the Miro unit from anywhere in the world, letting them change configurations, download data files, and view all data in real time through the online monitor. The Miro comes with the easy-to-use Citrus software which is equipped with one-click compliance reporting features.
Specifications
- Parameter
Range
- Voltage
Measurement 10/12 cycle rms
Range: 10% to 150% of nominal value with accuracy of +/-0.1% of nominal value under conditions specified in IEC61000-4-30 section 6.1.
- Frequency
Range 50Hz nominal (42.5-57.5)Hz, 60Hz nominal (51.0-69.0)Hz;
Full range: (40-70)Hz. Measurement: 10s; Accuracy: +/-5mHz referenced to RTC, +/-1mHz referenced to GPS.
- Flicker
IEC61000-4-15, 10 minute Pst (short term) and 2hr Plt (long term)
- Dips and Swells
Measurement: 1-cycle rms updated every half cycle.
Accuracy: +/-0.2% of nominal value, +/-1 cycle.
Range (magnitude) 0 to 200%.
Range (duration) minimum 0.5 cycles by definition. No upper limit.
- Voltage interruptions
Measurement: 1-cycle rms updated every half cycle.
Accuracy: +/- 1 cycle.
Range (duration) minimum 0.5 cycles by definition. No upper limit.
- Voltage and current unbalance
Applicable 3 phase systems and evaluated using the method of symmetrical components. Metrics: u2 = (U2/U1) and U0 = (U0/U1). U0, U1 and U2 are sequence components. Range: 0.5% to 5% of U2 and U0. Accuracy: ±0.15%.
- Power meter
Power-kW, Power-kVA, Power-kVAR, True Power Factor (TPF), Displacement Power Factor (DPF).
- Voltage Harmonics/Interharmonics
IEC61000-4-7, Class I (up to 50th harmonic). Range: 10% to 200% of Class 3 electromagnetic environment in IEC 61000-2-4. Metrics: voltage and current magnitude and angle.
51st to 100th: Indication only.
- Total Harmonic Distortion (THD)
IEC61000-4-7, THDS (up to 50th harmonic)
- Mains signalling (Ripple amplitude)
Signal: <3kHz, user specified frequency. 20Hz bandwidth (4-nearest-bins method, adjusted automatically to correct for fundamental drift).
Measurement: 10/12 cycle rms amplitude maximum value. Measurement range: 0%-15% of the nominal value. Detection threshold: >0.3% of nominal voltage, Duration: user defined from 1s to 300s. Trigger input to Ripple capture.
- RVC
RVC threshold: user defined between 1% and 6% of the nominal value. RVC hysteresis: user defined and < RVC threshold.
- Underdeviation / Overdeviation
Separately measure voltages above and below the nominal value. Metrics: RMS-under, RMS-over, %U Under and %U Over.
- Crest factor
Indicates peak-to-rms ratio of waveform. ±1%.
- Temperature
Two temperature channels measured each second, recording at adjustable, 10-min and 2-hour intervals. Measurement:-50°C to +150°C. Accuracy: ±1°C.
To contact HK Calibration Technologies about Miro Power Quality Analyser PQ45 use Get a quote.
The PQ45 has the highest safety rating of all portable power quality analysers – CAT IV 600V. The fourth voltage channel on the PQ45 allows for ground-neutral voltage measurements. The integrated remote communication module (optional) allows the user to access the Miro unit from anywhere in the world, letting them change configurations, download data files, and view all data in real time through the online monitor. The Miro comes with the easy-to-use Citrus software which is equipped with one-click compliance reporting features.
Specifications
- Parameter
Range
- Voltage
Measurement 10/12 cycle rms
Range: 10% to 150% of nominal value with accuracy of +/-0.1% of nominal value under conditions specified in IEC61000-4-30 section 6.1.
- Frequency
Range 50Hz nominal (42.5-57.5)Hz, 60Hz nominal (51.0-69.0)Hz;
Full range: (40-70)Hz. Measurement: 10s; Accuracy: +/-5mHz referenced to RTC, +/-1mHz referenced to GPS.
- Flicker
IEC61000-4-15, 10 minute Pst (short term) and 2hr Plt (long term)
- Dips and Swells
Measurement: 1-cycle rms updated every half cycle.
Accuracy: +/-0.2% of nominal value, +/-1 cycle.
Range (magnitude) 0 to 200%.
Range (duration) minimum 0.5 cycles by definition. No upper limit.
- Voltage interruptions
Measurement: 1-cycle rms updated every half cycle.
Accuracy: +/- 1 cycle.
Range (duration) minimum 0.5 cycles by definition. No upper limit.
- Voltage and current unbalance
Applicable 3 phase systems and evaluated using the method of symmetrical components. Metrics: u2 = (U2/U1) and U0 = (U0/U1). U0, U1 and U2 are sequence components. Range: 0.5% to 5% of U2 and U0. Accuracy: ±0.15%.
- Power meter
Power-kW, Power-kVA, Power-kVAR, True Power Factor (TPF), Displacement Power Factor (DPF).
- Voltage Harmonics/Interharmonics
IEC61000-4-7, Class I (up to 50th harmonic). Range: 10% to 200% of Class 3 electromagnetic environment in IEC 61000-2-4. Metrics: voltage and current magnitude and angle.
51st to 100th: Indication only.
- Total Harmonic Distortion (THD)
IEC61000-4-7, THDS (up to 50th harmonic)
- Mains signalling (Ripple amplitude)
Signal: <3kHz, user specified frequency. 20Hz bandwidth (4-nearest-bins method, adjusted automatically to correct for fundamental drift).
Measurement: 10/12 cycle rms amplitude maximum value. Measurement range: 0%-15% of the nominal value. Detection threshold: >0.3% of nominal voltage, Duration: user defined from 1s to 300s. Trigger input to Ripple capture.
- RVC
RVC threshold: user defined between 1% and 6% of the nominal value. RVC hysteresis: user defined and < RVC threshold.
- Underdeviation / Overdeviation
Separately measure voltages above and below the nominal value. Metrics: RMS-under, RMS-over, %U Under and %U Over.
- Crest factor
Indicates peak-to-rms ratio of waveform. ±1%.
- Temperature
Two temperature channels measured each second, recording at adjustable, 10-min and 2-hour intervals. Measurement:-50°C to +150°C. Accuracy: ±1°C.
To contact HK Calibration Technologies about Miro Power Quality Analyser PQ45 use Get a quote.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Martel Thermocouple Calibrator | TC-100
Multi Gas Detector | BX 616
FlowMeter Calibration Services
Gas Monitoring Calibration Services
Multimeter Calibration Services
Digital Multimeter | 77-IV
Industrial Torque Wrench
Non Contact Voltage Clamp Meter | 377 FC
Digital Panel Meter | LCI508
Flow Meter | Dual Display Resetable
Hydraulic Pressure Test Pump | ADT 927
Pneumatic Hand Pumps | ADT 914
Pneumatic Test Pump | ADT 920
Process Indicator | Series LCI132
Process Controller | Series 2600
Digital Calipers | 150MM
Electronic Torque Wrench | Nortronic
Force Gauge | 5000G FG5005
Microwave Leakage Detector | EMF 810
Sound Level Meter | EM9200
Power Quality Analyser Power Master | MI 2892
Master Q4 | MI 2885 - Power Quality Analyser
Energy Master | MI 2883 | Power Quality Analyser
PQM4000 Class A Power Quality analyser
CHK Power Quality Analysers | Miro-F Transformer Monitor
CHK Power Quality | PQ45 | Precision Power Analyser
Power Quality Tool | Norma 6000 Series Portable Power Analyzers
1770 Series Three-Phase Power Quality Analyzers
Power Quality Analyser | SQRQ060129
Power Quality Analyser Three-Phase | Powerpad III 8333 AEMC
Power Quality Analyser | Hioki 3197
Power Quality Analyser | 1775
Power Quality Analyzer | PPA 500
Power Quality Analyser | 6830
Power Quality Analyser | eXpertPRO™ DIN EM235
Power Quality Analyser | PQA819
Power Quality Analyser | CET PMC-680i
Three Phase Power Quality Analyser | Tekon 570
Power Quality Analyser | Otii Arc
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product