Atomtex - X-ray Radiation Dosimeters | AT1103M
This highly-sensitive device measures radiation exposure on crystalline lens (eyes), mucus membranes (e.g. mouth, nasal passages) and skin.
The Atomtex AT1103M is a highly-sensitive device which monitors for low-energy, low-intensity X-ray radiation exposure from devices such as video display units, night vision devices, oscillographs, TV receivers, microwave emitters, ion implanters, search and medical continuous X-ray apparatus.
A NaI(Tl) ø9×2 mm scintillator with beryllium window is used in the dosimeter as an X-ray detector. The Atomtex AT1103M measures directed dose equivalent rate of continuous X-ray radiation with energy from 5 keV.
Features
- Search for X-ray and low-energy gamma radiation sources
- Quick accommodation to changes in radiation level
- Sound and visual alarm in case threshold level is exceeded
- Memory function for 100 measurement results
- Integrated system for measurement path LED stabilization, so there is no need for check radioactive source
- Analog-to-digital converter for 256 channels
- Dust and splash-proof design
- Not for natural background measuring
- Background component correction during measuring
Specifications
| Directional radiation dose equivalent rate measurement range | 50 nSv/h ... 100 µSv/h |
| Directional radiation dose equivalent measurement range | 50 nSv ... 5 mSv |
| Intrinsic relative measurement error | ±15% max |
| Registered X-ray radiation energy range | 5 ... 160 keV |
| Sensitivity for 241Am | 400 cps/µSv?h-1 |
| Calibration error for 241Am | ±5% max |
| Response time for dose rate change from 1 to 10 µSv/h | ≤2 s (accuracy error ≤±10%) |
| Detectable 241Am activity at 0.5 m distance for period <2 s | 1000kBq (27 µCi) |
Energy dependence relative to241Am
| 5 keV ... 60 keV | ±35% |
| 60 keV ... 160 keV | ±30% |
To contact Nuclear Australia about Atomtex X-ray Radiation Dosimeters | AT1103M use Get a quote.
The Atomtex AT1103M is a highly-sensitive device which monitors for low-energy, low-intensity X-ray radiation exposure from devices such as video display units, night vision devices, oscillographs, TV receivers, microwave emitters, ion implanters, search and medical continuous X-ray apparatus.
A NaI(Tl) ø9×2 mm scintillator with beryllium window is used in the dosimeter as an X-ray detector. The Atomtex AT1103M measures directed dose equivalent rate of continuous X-ray radiation with energy from 5 keV.
Features
- Search for X-ray and low-energy gamma radiation sources
- Quick accommodation to changes in radiation level
- Sound and visual alarm in case threshold level is exceeded
- Memory function for 100 measurement results
- Integrated system for measurement path LED stabilization, so there is no need for check radioactive source
- Analog-to-digital converter for 256 channels
- Dust and splash-proof design
- Not for natural background measuring
- Background component correction during measuring
Specifications
| Directional radiation dose equivalent rate measurement range | 50 nSv/h ... 100 µSv/h |
| Directional radiation dose equivalent measurement range | 50 nSv ... 5 mSv |
| Intrinsic relative measurement error | ±15% max |
| Registered X-ray radiation energy range | 5 ... 160 keV |
| Sensitivity for 241Am | 400 cps/µSv?h-1 |
| Calibration error for 241Am | ±5% max |
| Response time for dose rate change from 1 to 10 µSv/h | ≤2 s (accuracy error ≤±10%) |
| Detectable 241Am activity at 0.5 m distance for period <2 s | 1000kBq (27 µCi) |
Energy dependence relative to241Am
| 5 keV ... 60 keV | ±35% |
| 60 keV ... 160 keV | ±30% |
To contact Nuclear Australia about Atomtex X-ray Radiation Dosimeters | AT1103M use Get a quote.
The Atomtex AT1103M is a dosimeter that measures directed dose-equivalent rates from continuous X-ray radiation and registers X-ray energies from 5 keV to 160 keV. Its memory stores 100 measurement results, giving users a record of readings for later reference. For source-search work, its dust- and splash-proof design protects the device against dust and splashes during checks.
- Sound and visual alarms signal when the threshold level is exceeded
- Background component correction during measurements
- Measurement-path LED stabilisation means no check radioactive source is needed
- Intrinsic relative measurement error: ±15% maximum
- Dose-rate response from 1 to 10 µSv/h: 2 s (accuracy error ±10%)
Source: listing by Nuclear Australia on IndustrySearch · Updated 6 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Nuclear Australia on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Tracerco Radiation Dose Rate Monitor | T402
Radiation Survey Meter | TroxAlert
Radiation Monitor | AT6130
Gamma and X-ray Dosimeter | KOKA II ONE
Personal Electronic Dosimeters (PEDs)
Radiation Monitor | Airborne Particle Mobile Monitoring System - APMMS
Radiation Monitor | Austral-Rad Becquerel Monitor
Radiation Monitor | AustalRAD Mini Fukushima 3
Universal Light & Thermal Radiation Meter | Elsec 775
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product