BinMaster Capacitance Level Indicators ...
BinMaster - Capacitance Level Indicators for Hazardous Locations
BinMaster PROCAP IX and IIX capacitance sensors are designed for use in hazardous locations, featuring CSA Class I, Groups C & D and Class II, Groups E, F & G ratings
They are suitable for challenging environments where there is a risk of explosion, detecting high and low levels in bins, silos, tanks, hoppers, chutes and other vessels used for volatile material storage or process manufacturing. BinMaster capacitance sensors operate by detecting the presence or absence of material in contact with the probe by sensing minute changes (as low as 0.5 pF) in capacitance caused by the difference in the dielectric constant of the material versus the air. A wide assortment of probes and extensions make BinMaster capacitance probes appropriate for a variety of solid, liquid and slurry materials.
These intrinsically safe capacitance probes provide interference-free operation – working far below the RF level of 9 KHz at just 6 KHz. – and will not interfere with two-way radios or other equipment operating in the radio spectrum. They feature simple “quick set” calibration and fail-safe operation including an internal LED to indicate the sensor status. Accurate level detection is assured even in dusty , sticky or clinging materials by the PRO-shield feature which compensates for material build up on the sensing probe. It also provides fail-safe protection in the event of a power failure as well as an adjustable time delay to help prevent false readings.
Features:
- Explosion proof design for Class I hazardous location applications
- “Quick-Set” simple calibration
- Triple thread screw-off cover
- Dual conduit entrance
- Unsurpassed sensitivity 0.5 pF
- PRO-Shield compensates for material buildup
- Operates below RF range, temperature stable calibration and protection from RF interference
- Fail-safe, switch selectable high/low
- Adjustable time delay to 30 seconds
- Optional sensing probes: Delrin or Teflon sleeved, food grade, flush mount, solid and flexible extensions
To contact Pacific Sensor Technologies Pty Ltd about BinMaster Capacitance Level Indicators for Hazardous Locations use Get a quote.
They are suitable for challenging environments where there is a risk of explosion, detecting high and low levels in bins, silos, tanks, hoppers, chutes and other vessels used for volatile material storage or process manufacturing. BinMaster capacitance sensors operate by detecting the presence or absence of material in contact with the probe by sensing minute changes (as low as 0.5 pF) in capacitance caused by the difference in the dielectric constant of the material versus the air. A wide assortment of probes and extensions make BinMaster capacitance probes appropriate for a variety of solid, liquid and slurry materials.
These intrinsically safe capacitance probes provide interference-free operation – working far below the RF level of 9 KHz at just 6 KHz. – and will not interfere with two-way radios or other equipment operating in the radio spectrum. They feature simple “quick set” calibration and fail-safe operation including an internal LED to indicate the sensor status. Accurate level detection is assured even in dusty , sticky or clinging materials by the PRO-shield feature which compensates for material build up on the sensing probe. It also provides fail-safe protection in the event of a power failure as well as an adjustable time delay to help prevent false readings.
Features:
- Explosion proof design for Class I hazardous location applications
- “Quick-Set” simple calibration
- Triple thread screw-off cover
- Dual conduit entrance
- Unsurpassed sensitivity 0.5 pF
- PRO-Shield compensates for material buildup
- Operates below RF range, temperature stable calibration and protection from RF interference
- Fail-safe, switch selectable high/low
- Adjustable time delay to 30 seconds
- Optional sensing probes: Delrin or Teflon sleeved, food grade, flush mount, solid and flexible extensions
To contact Pacific Sensor Technologies Pty Ltd about BinMaster Capacitance Level Indicators for Hazardous Locations use Get a quote.
BinMaster PROCAP IX and IIX capacitance sensors detect high and low material levels in bins, silos, tanks, hoppers and chutes. Their PRO-Shield feature compensates for material buildup on the sensing probe, helping detect levels in dusty, sticky or clinging materials. They suit volatile-material storage and process manufacturing, with probe and extension choices for solid, liquid and slurry materials.
- CSA ratings: Class I, Groups C & D; Class II, Groups E, F & G
- Senses capacitance changes as low as 0.5 pF
- Operates at 6 KHz, below the 9 KHz RF level, without radio-spectrum interference
- Quick-Set calibration; internal LED indicates sensor status
- Fail-safe operation; power-failure protection; switch-selectable high/low; adjustable delay to 30 seconds
Source: listing by Pacific Sensor Technologies Pty Ltd on IndustrySearch · Updated 1 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Pacific Sensor Technologies Pty Ltd on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
HiTemp140 | High Temperature Data logger
PR140 - Pressure Data logger for Autoclave validation and mapping
Data Acquisition Logger | Titan S8
Autoclave Validation Data Loggers/System | AVS140-1
Data Loggers - PST Autoclave Validation Kit-2
Bin and Tank Rotary Level Indicators | BMRX
Data Logger - UltraShock | Tri-axial compact shock data logger
pH meter | pH tester Range
WiFi Data Logger Series
MW500 - Standard ORP Meters
Soil Testing - NPK Soil Test Kit - MT6003
Temperature Sensors | 4 - 20mA Output
Data Loggers VoltX Series - 4, 8, 12, and 16-channel DC voltage
Element CO2 - Wireless CO2, humidity and temperature data logger
ODEON - Handheld Water Quality meter / Data Logger
Environmental/Sound Level Meter Lightmeter C530
AC/DC Clamp Meter with Smart Detection Function -C21
Multilogger Thermo Hygro Meter - Ethernet Data Logger | M1140
Custom Made Thermocouples
Laboratory Calibration Services
Bin and Tank Rotary Level Indicators | BMRX
Standard 7-Inch Vibrating Rod VR-21 - Point Level Indicator
Standard Capacitance Level Indicators
Maxima+ Fail-Safe Rotary Level Indicator
Capacitance Level Indicators
Rotary Level Indicators
Magnetic Visual Level Indicators | 34000
Visual Level Indicators - 'Top Of Tank'
Visual Level Indicators - 64000 / 66000
High Pressure Visual Level Indicators
Level Switches for Magnetic Visual Level Indicators
Continuous Level Indicator | Ramsey C-Level
Magnetic Level Indicator and Gauges - Magnicator II
Flat Glass Level Indicator
Eye-Hye Conductivity Probe Column | Level Indicators
Oil Level Indicator
Bypass Level Indicator | Magnetic Display | BNA
Level Indicator | UTN | Top Mounted
Level Indicator | Auto-Set ATS8V0A
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product