Newtronic Walk-In Cooling (Coolroom) ...
Newtronic - Walk-In Cooling (Coolroom) Chambers
Walk-In Cooling (Cold Rooms) Chambers
These are medium to large-sized chambers that are custom-built to ensure that they not only fit optimally in your lab's stability area but also address your large-scale stability testing requirements.
Walk-In Chambers have now become a de-facto requirement for companies planning multiple ANDA filings & planning to launching various products simultaneously.
NEWTRONIC Walk-Ins ensure a smooth air-flow pattern to improve the temperature & humidity distribution across the chamber. This has also led to huge load reduction on the heating, cooling & humidifier systems. This & many other innovations in the construction & design aspects have ensured dramatic reduction in power consumption of our Walk-Ins.
NEWTRONIC has also been regularly exporting the Walk-In Chambers to all the major markets of the world. We ensure our products meet all kinds of country-specific requirements such as voltage specifications, regulatory needs, container shipping, etc.
Features
- Ethernet Communication
- High-speed data transfer
- Significantly faster than serial(RS-485) communication
- Global standard for communication protocol
- No need for a separate PC interface
- Data Operations from any PC over the LAN
- Standby Humidity & Cooling System
- Completely ready-to-use systems
- Automatic switch-over upon failure of primary systems to achieve conditions
- Switch-over also upon detection of HP/LP & Internal fault
- Scheduled & manual change-overs
- Recording of all change-overs in the software
- PLC-Based Control System
- Complete Operations driven through PLC
- No Data Loss: Data Storage of up to 1000 readings on the PLC itself
- At an interval of 30 mins, data up to 20 days is stored on the PLC itself
- Facility to send emails directly from the PLC
- Touch Screen Display
- All operations through a single 4" Color touch screen display
- PLC IP Address setting
- Component Working Hours
- Standby system change over
- Password protection for set values and calibration mode
- E-Mail Alert
- When an alarm is triggered, an e-mail is sent to the registered PC or mobile address
- *connection to a mail server is required to use e-mail alert.
- Complete Range of Alarms
- Temperature & Humidity Deviations
- Door Opening
- Water Supply Failure
- Component Failure
- Mains Failure
- Documentation & Training
- IQ, OQ, PQ
- Calibration certificates
- Operations & maintenance manuals
- GA & Electrical drawings
- Material test certificates
- Training to end-users
- Safety
- Temperature Overshoot/Undershoot
- Humidity Overshoot
- Low water-level
- Delay Timer to safeguard the Compressor
- MCB to cut-off over-current supply
- Standby Controlling Sensor upon failure of Primary
- In Walk-in chambers door can be open from inside
- Emergency Bell switch inside the Chamber
- ICDAS Software
- 21 CFR Part 11 Ready
- Single software suitable for up to 20 equipment
- Automatic daily data back-up
- Alarm logs. Alarm acknowledgement with e-signatures
- Audit trails
- MKT Calculations
- Graphical viewing & data trending
- Data export in pdf format
- Touchscreen Door Access System
- Password based access control
- Restricts access to unauthorized persons
- Alarm Transmission
- Mobile alert system
- Time of alarm transmission
- Name of equipment
- Transmitted message(Equipment name, alarm time, type of alarm & limits)
Specifications
| Temperature Range | 2°C to 8°C |
| Temperature Accuracy | ± 0.5°C |
| Temperature Uniformity | ± 1°C |
Standard Equipment
| Double walled with 80mm PUF insulated modular panels with easy on-site assembly | System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room |
| SS 304 Interior & Exterior either SS 304 or Powder Coated G.I. | Stand by humidity system |
| Stainless Steel Trays | Complete Operations driven through PLC with data logging capacity of upto 1000 readings & email facility |
| Observation window - 300 x 300 mm | High speed Ethernet based communication |
| Illuminated working area | All operations through a single 4" Color Touch Screen |
| U-shaped SS tubular heaters | High-quality German Make temperature humidity sensor with 4-20mA output |
| Flooring of Linoleum carpet | Safety devices: Low & High temperature cut-off settable thermostats & high humidity cut-off device |
| Forced air circulation for uniform temperature | Audio/Visual alarms for deviations |
| Non Condensing steam injection type humidity system with standby heater & auto switch overs | Complete with IQ, OQ, PQ & Operations & Maintenance Manual |
| CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser | |
Power supply: 230/415 volts 50 Hz main supply. Also available with 60 Hz Cycle.
Optional Accessories
| ICDAS - A Common Software suitable for 20 nos. Newtronic make equipment | Door Access system (Numeric or Biometric) |
| 8pt. Temperature & Humidity Scanners | Mobile Alert system |
| Stand by Cooling System with auto switch overs | Remote alarm system suitable for 4 nos. Newtronic make equipment |
To contact Biotec Solutions about Newtronic Walk-In Cooling (Coolroom) Chambers use Get a quote.
These are medium to large-sized chambers that are custom-built to ensure that they not only fit optimally in your lab's stability area but also address your large-scale stability testing requirements.
Walk-In Chambers have now become a de-facto requirement for companies planning multiple ANDA filings & planning to launching various products simultaneously.
NEWTRONIC Walk-Ins ensure a smooth air-flow pattern to improve the temperature & humidity distribution across the chamber. This has also led to huge load reduction on the heating, cooling & humidifier systems. This & many other innovations in the construction & design aspects have ensured dramatic reduction in power consumption of our Walk-Ins.
NEWTRONIC has also been regularly exporting the Walk-In Chambers to all the major markets of the world. We ensure our products meet all kinds of country-specific requirements such as voltage specifications, regulatory needs, container shipping, etc.
Features
- Ethernet Communication
- High-speed data transfer
- Significantly faster than serial(RS-485) communication
- Global standard for communication protocol
- No need for a separate PC interface
- Data Operations from any PC over the LAN
- Standby Humidity & Cooling System
- Completely ready-to-use systems
- Automatic switch-over upon failure of primary systems to achieve conditions
- Switch-over also upon detection of HP/LP & Internal fault
- Scheduled & manual change-overs
- Recording of all change-overs in the software
- PLC-Based Control System
- Complete Operations driven through PLC
- No Data Loss: Data Storage of up to 1000 readings on the PLC itself
- At an interval of 30 mins, data up to 20 days is stored on the PLC itself
- Facility to send emails directly from the PLC
- Touch Screen Display
- All operations through a single 4" Color touch screen display
- PLC IP Address setting
- Component Working Hours
- Standby system change over
- Password protection for set values and calibration mode
- E-Mail Alert
- When an alarm is triggered, an e-mail is sent to the registered PC or mobile address
- *connection to a mail server is required to use e-mail alert.
- Complete Range of Alarms
- Temperature & Humidity Deviations
- Door Opening
- Water Supply Failure
- Component Failure
- Mains Failure
- Documentation & Training
- IQ, OQ, PQ
- Calibration certificates
- Operations & maintenance manuals
- GA & Electrical drawings
- Material test certificates
- Training to end-users
- Safety
- Temperature Overshoot/Undershoot
- Humidity Overshoot
- Low water-level
- Delay Timer to safeguard the Compressor
- MCB to cut-off over-current supply
- Standby Controlling Sensor upon failure of Primary
- In Walk-in chambers door can be open from inside
- Emergency Bell switch inside the Chamber
- ICDAS Software
- 21 CFR Part 11 Ready
- Single software suitable for up to 20 equipment
- Automatic daily data back-up
- Alarm logs. Alarm acknowledgement with e-signatures
- Audit trails
- MKT Calculations
- Graphical viewing & data trending
- Data export in pdf format
- Touchscreen Door Access System
- Password based access control
- Restricts access to unauthorized persons
- Alarm Transmission
- Mobile alert system
- Time of alarm transmission
- Name of equipment
- Transmitted message(Equipment name, alarm time, type of alarm & limits)
Specifications
| Temperature Range | 2°C to 8°C |
| Temperature Accuracy | ± 0.5°C |
| Temperature Uniformity | ± 1°C |
Standard Equipment
| Double walled with 80mm PUF insulated modular panels with easy on-site assembly | System is made up of split type condenser unit in well-ventilated area to avoid throw of hot air in the room |
| SS 304 Interior & Exterior either SS 304 or Powder Coated G.I. | Stand by humidity system |
| Stainless Steel Trays | Complete Operations driven through PLC with data logging capacity of upto 1000 readings & email facility |
| Observation window - 300 x 300 mm | High speed Ethernet based communication |
| Illuminated working area | All operations through a single 4" Color Touch Screen |
| U-shaped SS tubular heaters | High-quality German Make temperature humidity sensor with 4-20mA output |
| Flooring of Linoleum carpet | Safety devices: Low & High temperature cut-off settable thermostats & high humidity cut-off device |
| Forced air circulation for uniform temperature | Audio/Visual alarms for deviations |
| Non Condensing steam injection type humidity system with standby heater & auto switch overs | Complete with IQ, OQ, PQ & Operations & Maintenance Manual |
| CFC free cooling system consisting of hermetically sealed compressor coupled with evaporation coil & condenser | |
Power supply: 230/415 volts 50 Hz main supply. Also available with 60 Hz Cycle.
Optional Accessories
| ICDAS - A Common Software suitable for 20 nos. Newtronic make equipment | Door Access system (Numeric or Biometric) |
| 8pt. Temperature & Humidity Scanners | Mobile Alert system |
| Stand by Cooling System with auto switch overs | Remote alarm system suitable for 4 nos. Newtronic make equipment |
To contact Biotec Solutions about Newtronic Walk-In Cooling (Coolroom) Chambers use Get a quote.
Newtronic Walk-In Cooling Chambers are custom-built, medium-to-large chambers that control temperature and humidity throughout the enclosed interior. Ethernet communication lets users manage data from any PC on the LAN without a separate PC interface. Laboratories preparing multiple ANDA filings and planning to launch several products simultaneously can have chambers built to fit their stability area.
- PLC stores up to 1,000 readings
- PLC stores data for up to 20 days at 30-minute intervals
- Temperature range: 2°C to 8°C; accuracy: ±0.5°C
- Temperature uniformity: ±1°C
- Standby humidity system switches over automatically if the primary system fails
Source: listing by Biotec Solutions on IndustrySearch · Updated 2 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Biotec Solutions on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Capsule Filling Machines | F125
Laboratory Oven
Walk-In Incubator
BOD Incubator
Walk-In Cooling (Coolroom) Chambers
Laboratory Deep Freezers
Walk-In Stability Humidity Chamber
Stability Humidity Chambers
Softgel Encapsulation Machine | 500R
Softgel Encapsulation Machine | 880SR
Softgel Encapsulation Machine | 770SR
CIP Tumble Dryer
Coating Machine | SFC Series
Laboratory Coating Machine | C Series
Laboratory Coating Machine | C30
Capsule Filling Machine | F180
Capsule Filling Machine | F3
Tablet Pressing Machine | P230D
Tablet Pressing Machine | P210S
Tablet Pressing Machine | P130S
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.