Fluke 117 Electrician's Digital Multimeter ...
Fluke - 117 Electrician's Digital Multimeter with Non-Contact Voltage
Is a versatile tool for electricians, offering accurate voltage, current, and resistance measurements. Its compact design, easy-to-read display, and built-in features make it perfect for both residential and commercial use.
The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for:
- Resistance
- Continuity
- Frequency
- Capacitance
- Min/Max/Average
For the Everyday
A digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like:
- Commercial buildings
- Hospitals
- Schools
Non-Contact Voltage Detection
Keep yourself safer with integrated VoltAlert™ technology. Fast, go/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started.
Automatic AC/DC Selection
Set the dial and get your measurement quickly with AutoVolt. This automatic AC/DC voltage selector makes it easier for you to get the measurement you need and move on quicker.
Specifications: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
|
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -40°C to +60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
| AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max |
|
| DC amps | Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years | |
Models: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
Includes:
- 4 mm silicone test lead set
- Holster
- User manual
To contact Fluke Australia about Fluke 117 Electrician's Digital Multimeter with Non-Contact Voltage use Get a quote.
The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for:
- Resistance
- Continuity
- Frequency
- Capacitance
- Min/Max/Average
For the Everyday
A digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like:
- Commercial buildings
- Hospitals
- Schools
Non-Contact Voltage Detection
Keep yourself safer with integrated VoltAlert™ technology. Fast, go/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started.
Automatic AC/DC Selection
Set the dial and get your measurement quickly with AutoVolt. This automatic AC/DC voltage selector makes it easier for you to get the measurement you need and move on quicker.
Specifications: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
|
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -40°C to +60°C | |
| Battery type | 9 volt Alkaline, IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
|
| AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
|
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. |
|
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max |
|
| DC amps | Range/resolution |
6.000 A / 0.001 A 10.00 A / 0.01 A |
| Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max |
|
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. |
||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
| Warranty | 3 years | |
Models: Fluke 117 Electrician's Multimeter with Non-Contact Voltage
Includes:
- 4 mm silicone test lead set
- Holster
- User manual
To contact Fluke Australia about Fluke 117 Electrician's Digital Multimeter with Non-Contact Voltage use Get a quote.
The Fluke 117 is a True-rms digital multimeter for electrical measurements including voltage, current, resistance, continuity, frequency and capacitance. Its integrated VoltAlert provides fast go/no-go non-contact voltage detection, so electricians can start checks without carrying or finding a separate tool. Electricians in schools, hospitals or commercial buildings can use its bright backlight to read the display on darker worksites.
- CAT III 600 V; IEC 61010-1 Pollution Degree 2 and IEC 61010-2-033
- Display: 6,000 counts, updates 4 times per second
- Battery life: 400 hours typical without backlight
- 3-year warranty
- Includes 4 mm silicone test leads, holster and user manual
Source: listing by Fluke Australia on IndustrySearch
· Updated 2 Nov 2026
Specification sheet: Extended Specs For 114, 115, 116, 117 (PDF)
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Fluke Australia on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Leaks + Conveyors + Partial discharge - Fluke ii915 Acoustic Imager
Locate air, gas and vacuum leaks - Industrial Acoustic Imager - ii905
Fluke's Most Affordable Leak Detector - ii500 Acoustic Imager
TiX875 & TiX885 Thermal Camera with GPS
TiX580 Infrared Camera
Ti480U, Ti401U, & Ti300U Ultra Series Infrared Thermal Cameras
TiX1060 Extreme High Resolution Thermal Camera
Ti480 PRO Infrared Camera
TiS75+ Thermal Camera
TiS55+ Thermal Camera
TiS60+ Thermal Camera
TiS20+ / TiS20+ MAX Thermal Imaging Camera
Compact PTi120 Pocket Thermal Camera
SmartView R&D Thermal Imaging Software
1770 Series Three-Phase Power Quality Analyzers
Power Quality Tool | Norma 6000 Series Portable Power Analyzers
Power Quality Loggers | 1732 & 1734 Three-Phase Electrical Logger
1742, 1746 and 1748 Three-Phase Power Quality Loggers
190 Series III ScopeMeter® Test Tools
MDA-550 Series III Motor Drive Analyzer
Digital Multimeters & Power Analysers | DMG Series
Digital Multimeters | DMK2
Handheld Digital Multimeter | Mastech
Digital Multimeters | DME D130
Digital Multimeters | MD 9060
Digital Multimeters | MD 9010
DT830B Digital Multimeter
USB Digital Multimeter - 6½-Digit
4.5-digit Handheld Digital Multimeter w/ Organic LED Display | U1253B
True RMS 6000 Count Handheld Digital Multimeter | U1233A
Handheld Digital Multimeters, Clamps & Calibrator Meters | Keysight
PXI Digital Multimeter | M9181A
PXI Digital Multimeter | M9182A
Digital Multimeter | 760-1
Digital Multimeter | 760-2
Digital Multimeter | 760-3
Digital Multimeter with Datalogging (Wireless) | DM91 | TRMS
Digital Multimeter | DM93 | True RMS
Digital Multimeter with Non-Contact Voltage | DM62
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
