High Voltage Split Core CT Current Transformer - 11KV 33KV LZCK322-10

Supplier: Beijing GFUVE Electronics Co.,Ltd.

The High Voltage Split Core CT Current Transformer is suitable for current measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.

Price Guide (Inc GST): POA

The LZCK322-10 High Voltage Split Core CT Current Transformer is widely used in compact fully insulated ring network switch gears such as ABB-Safe Ring/Safe Plus and cable distribution boxes. The transformer can be directly installed at the inlet and outlet cables. The slice is imported silicon material. These micircular ring core and secondary windings are vacuum poured by insulated resin.

Front View of Resin Split Core Current Transformer,doule ratio

P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
P2, S2 is homonymous terminals (subtractive polarity).

Parameters 

Technical parameters
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006
Rated primary current 30-600A
Rated load ≤10VA
Rated frequency 50Hz or 60Hz
Rated secondary current 5A or 1A
Rated short-time thermal current 40kA, 1S
Rated continuous thermal current 120%I1n
Secondary winding power-frequency voltage 3kV, 1min
Instrument security factor FS≤10
Mechanical parameters
Dimensions (W×D×H) (mm) φ50xφ110x52
Weight (kg) 1.6
Operating conditions
Operating temperature -35°C to +55°C
Daily average temp <+40°C
Altitude <3500 meters
Condition No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.

Technical Data 

TypeLZCK322-10LZCK322-10
PurposeMeasuring current transformerProtection current transformer
RatioAccuracy class and rated load(VA)Accuracy class and rated load(VA)
I1/I2 0.5 1 3 10P15 10P10 10P5
30/1   1 1.5      
50/1   1 2     1.25
75/1   1.5 2.5   1 2
100/1 2 2.5 3   1.5 2.5
200/1 2.5     1.25 2.5  
300/1 3.75     1.25 2.5  
400/1 7.5     1.25 2.5  
500/1 10     1.25 3  
600/1 10     1.5 3  
50/5     2.5      
75/5     2.5      
100/5 2.5          
200/5 3.75          
300/5 5          
400/5 7.5       2.5  
500/5 7.5       2.5  
600/5 10       3.75  

Selection Guide

 ModelPrimary rated currentRated loadAperture (mm)Description (mm)Weight (kg)MaterialWater-proof
LZCK-55 100-1500A ≤10VA φ55 180×138×52 2 PC  IP65
LMCK185-10 300-3000A ≤25VA φ185 350×283×55 4.5 PC  IP65
LZCK310-10 300-600A ≤10VA φ50 φ50 x φ110 x 32 1 Resin silicon case (option)
LZCK322-10 30-600A ≤10VA φ50 φ50 x φ110 x 52 1.6 Resin silicon case (option)
LZCK350-10 20-600A ≤25VA φ50 φ50 x φ110 x 105 3.1 Resin silicon case (option)
LZCG530-10 30-600A ≤20VA φ45 φ45 x φ120 x 65 2.1 Resin silicon case (option)

View more information on High Voltage Split Core CT Current Transformer