Evident Thickness Gauge 0.50 mm to 635 mm ...
Evident - Thickness Gauge 0.50 mm to 635 mm | 27MG
The 27MG basic ultrasonic thickness gauge is designed to accurately measure thickness from one side on internally corroded or eroded metal pipes and parts. It is lightweight, durable, and ergonomically designed for easy, one-hand operation.
The Evident 27MG is an affordable ultrasonic thickness gauge designed to make accurate, measurements from one side on internally corroded or eroded metal pipes, tanks, and other equipment. It weighs only 12 oz. (340 g) and is ergonomically designed for easy, one-hand operation. Despite its compact size, the 27MG has many innovative measurement features utilizing the same technologies that are available on our more advanced thickness gauges. The durable, rugged 27MG is battery-operated and features a large, backlit LCD with easy-to-read numerals, and an intuitive color-coded keypad with direct access to many key features.
Standard features include Automatic Probe Recognition to ensure optimal transducer performance, Auto Zero compensation to enhance the accuracy of measurements on hot surfaces, Gain Adjust to improve measurements on sound-attenuating materials such as cast metals, Differential mode, Hi-Low Alarm settings, and a Min./Max. mode that captures the minimum or maximum thickness at 20 measurements per second.
The 27MG is designed for inspectors and maintenance engineers that need to monitor the wall thickness in metal pipes, tanks, beams, and structural supports that are susceptible to corrosion on the inside surface. An ultrasonic thickness gauge provides a quick, cost-effective solution by transmitting sound into the material from the outside, making it unnecessary to damage the part.
Transducers
The 27MG comes standard with the low-cost D7910 dual element transducer that enables you to make thickness measurement for many basic corrosion applications. For measurements on very thin or thick materials, or small diameter pipes, Evident has available a full line of dual element transducers. Evident transducers compatible with the 27MG feature Automatic Probe Recognition that optimizes transducer performance by automatically recalling the default V-path correction.
Specifications:
Measurements > Dual element transducer measurement mode
Time interval from a precision delay after the excitation pulse to the first echo
|
Measurements > Thickness range |
0.50 mm to 635 mm (0.020 in. to 25.0 in.) depending on material, transducer, surface conditions, temperature |
|
Measurements > Material velocity range |
0.508 mm/μs to 18.699 mm/μs (0.020 in./μs to 0.7362 in./μs) |
|
Measurements > Resolution (selectable) |
Low: 0.1 mm (0.01 in.) |
|
Measurements > Transducer frequency range |
2.25 MHz to 10 MHz (–3 dB) |
|
General > Operating temperature range |
-10 °C to 50 °C (14 °F to 122 °F) |
|
General > Keypad |
Sealed, color-coded keypad with tactile and audible feedback |
|
General > Case |
Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP65. |
|
General > Dimensions (W x H x D) |
84.0 mm x 152.4 mm x 39.6 mm (3.31 in. x 6.0 in. x 1.56 in.) |
|
General > Weight |
340 g (12 oz) |
|
General > Power Supply |
3 AA alkaline batteries |
|
General > Battery life operating time |
150 h of typical battery life, 30 h continuous use with backlight |
|
General > Explosive Atmosphere |
Tested using MIL-STD-810F 511.4 Procedure I |
|
General > Standards |
Designed for EN15317 |
|
General > Alarm mode |
Programmable Hi/Low set points with audible and visual indicators |
|
Display > Display Hold/Blank mode |
Holds or blanks the display after measurements |
|
Display > Backlight |
Electroluminescent backlight, Selectable as On or Auto On |
|
Display > Receiver bandwidth |
1 MHz to 18 MHz (–3 dB) |
|
Display > Metric/English mode |
Metric or English units |
|
Display > Display languages |
English, French, German, Spanish, Italian,Portuguese, Russian, Polish, and Swedish |
Standard Package
- 27MG digital ultrasonic thickness gauge
- Dual element transducer
- AA alkaline batteries
- Test block and couplant
- Carrying case
- Wrist strap
- User’s manual on CD
- Getting started Guide
- Measurement features: Min./Max. mode, Differential mode, Gain Adjust Freeze mode, Automatic Probe Recognition, Zero Compensation
Standard inclusions may vary depending on your location. Contact your local distributor.
Optional Accessories
- 2214E (U8880014): 5-step test block, English units
- 2214M (U8880016): 5-step test block, metric units
- 27MG/RPC (U8780343): Protective rubber boot with Neck Strap and Gauge Stand
For additional accessories such as holders, wands, and couplants, please consult Evident.
Transducers
Transducers with Automatic Probe Recognition
The 27MG is compatible with our complete line of easy interchangeable dual element transducers that vary in frequencies, diameters, and temperature capabilities to deal with virtually every application.
1 Dependent on material, transducer type, surface conditions, and temperature. Full range may require Gain Adjust.
2 Maximum temperature with intermittent contact only.
3 Stainless steel cable available; consult Evident for details.
To contact Evident Australia about Evident Thickness Gauge 0.50 mm to 635 mm | 27MG use Get a quote.
The Evident 27MG is an affordable ultrasonic thickness gauge designed to make accurate, measurements from one side on internally corroded or eroded metal pipes, tanks, and other equipment. It weighs only 12 oz. (340 g) and is ergonomically designed for easy, one-hand operation. Despite its compact size, the 27MG has many innovative measurement features utilizing the same technologies that are available on our more advanced thickness gauges. The durable, rugged 27MG is battery-operated and features a large, backlit LCD with easy-to-read numerals, and an intuitive color-coded keypad with direct access to many key features.
Standard features include Automatic Probe Recognition to ensure optimal transducer performance, Auto Zero compensation to enhance the accuracy of measurements on hot surfaces, Gain Adjust to improve measurements on sound-attenuating materials such as cast metals, Differential mode, Hi-Low Alarm settings, and a Min./Max. mode that captures the minimum or maximum thickness at 20 measurements per second.
The 27MG is designed for inspectors and maintenance engineers that need to monitor the wall thickness in metal pipes, tanks, beams, and structural supports that are susceptible to corrosion on the inside surface. An ultrasonic thickness gauge provides a quick, cost-effective solution by transmitting sound into the material from the outside, making it unnecessary to damage the part.
Transducers
The 27MG comes standard with the low-cost D7910 dual element transducer that enables you to make thickness measurement for many basic corrosion applications. For measurements on very thin or thick materials, or small diameter pipes, Evident has available a full line of dual element transducers. Evident transducers compatible with the 27MG feature Automatic Probe Recognition that optimizes transducer performance by automatically recalling the default V-path correction.
Specifications:
Measurements > Dual element transducer measurement mode
Time interval from a precision delay after the excitation pulse to the first echo
|
Measurements > Thickness range |
0.50 mm to 635 mm (0.020 in. to 25.0 in.) depending on material, transducer, surface conditions, temperature |
|
Measurements > Material velocity range |
0.508 mm/μs to 18.699 mm/μs (0.020 in./μs to 0.7362 in./μs) |
|
Measurements > Resolution (selectable) |
Low: 0.1 mm (0.01 in.) |
|
Measurements > Transducer frequency range |
2.25 MHz to 10 MHz (–3 dB) |
|
General > Operating temperature range |
-10 °C to 50 °C (14 °F to 122 °F) |
|
General > Keypad |
Sealed, color-coded keypad with tactile and audible feedback |
|
General > Case |
Impact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP65. |
|
General > Dimensions (W x H x D) |
84.0 mm x 152.4 mm x 39.6 mm (3.31 in. x 6.0 in. x 1.56 in.) |
|
General > Weight |
340 g (12 oz) |
|
General > Power Supply |
3 AA alkaline batteries |
|
General > Battery life operating time |
150 h of typical battery life, 30 h continuous use with backlight |
|
General > Explosive Atmosphere |
Tested using MIL-STD-810F 511.4 Procedure I |
|
General > Standards |
Designed for EN15317 |
|
General > Alarm mode |
Programmable Hi/Low set points with audible and visual indicators |
|
Display > Display Hold/Blank mode |
Holds or blanks the display after measurements |
|
Display > Backlight |
Electroluminescent backlight, Selectable as On or Auto On |
|
Display > Receiver bandwidth |
1 MHz to 18 MHz (–3 dB) |
|
Display > Metric/English mode |
Metric or English units |
|
Display > Display languages |
English, French, German, Spanish, Italian,Portuguese, Russian, Polish, and Swedish |
Standard Package
- 27MG digital ultrasonic thickness gauge
- Dual element transducer
- AA alkaline batteries
- Test block and couplant
- Carrying case
- Wrist strap
- User’s manual on CD
- Getting started Guide
- Measurement features: Min./Max. mode, Differential mode, Gain Adjust Freeze mode, Automatic Probe Recognition, Zero Compensation
Standard inclusions may vary depending on your location. Contact your local distributor.
Optional Accessories
- 2214E (U8880014): 5-step test block, English units
- 2214M (U8880016): 5-step test block, metric units
- 27MG/RPC (U8780343): Protective rubber boot with Neck Strap and Gauge Stand
For additional accessories such as holders, wands, and couplants, please consult Evident.
Transducers
Transducers with Automatic Probe Recognition
The 27MG is compatible with our complete line of easy interchangeable dual element transducers that vary in frequencies, diameters, and temperature capabilities to deal with virtually every application.
1 Dependent on material, transducer type, surface conditions, and temperature. Full range may require Gain Adjust.
2 Maximum temperature with intermittent contact only.
3 Stainless steel cable available; consult Evident for details.
To contact Evident Australia about Evident Thickness Gauge 0.50 mm to 635 mm | 27MG use Get a quote.
The Evident 27MG is an ultrasonic gauge that measures metal thickness from one side across 0.50 mm to 635 mm, depending on material, transducer, surface conditions and temperature. Automatic Probe Recognition optimises transducer performance by recalling its default V-path correction. Inspectors and maintenance engineers can monitor wall thickness in pipes, tanks, beams and structural supports susceptible to internal corrosion.
- Minimum/maximum mode captures thickness at 20 measurements per second
- Selectable resolution: 0.1 mm low or 0.01 mm standard
- 150 h typical battery life; 30 h continuous use with backlight
- Impact-resistant, water-resistant case designed for IP65
- Dual-element transducer, AA batteries, test block and couplant included; contents vary by location
Source: listing by Evident Australia on IndustrySearch · Updated 5 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Evident Australia on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Benchtop XRF Analyzer | Evident Vanta GX
Thickness Gauge 0.08 mm to 635 mm | 39DL PLUS
Thickness Gauge 0.080 mm to 635 mm | 45MG
Handheld XRF Analyzer IP54 Rated | Vanta Element
Handheld XRF Analyzer 55 kV Tungsten | Vanta Max
Thickness Gauge Range up to 25.4 mm | Magna-Mike 8600
Thickness Gauge 0.50 mm to 635 mm | 27MG
Thickness Gauge 0.63 mm to 22.8 mm | 35RDC
Thickness Gauge High-resolution Touch Screen | 72DL PLUS
Ultrasonic Flaw Detector IP66/67 | EPOCH 650
Ultrasonic Flaw Detector IP65/67 | EPOCH 6LT
Ultrasonic Flaw Detector 8.4-inch Touch Screen | OmniScan SX
Eddy Current Sensor 16-Pin | Conductivity Probes and Standard
Handheld XRF Analyzer IP55/IP54 | Vanta Series
Video Borescopes 20-30 Meter Scope | IPLEX GAir
Video Borescopes 186-Minute Battery Life | IPLEX GX/GT
Video Borescopes Interchangeable Scope | IPLEX NX
Video Borescopes IP65 | IPLEX G Lite/G Lite-W
Video Borescopes 1.8 mm Rigid Scope | IPLEX TX II
Transducer Cables | Evident Australia
Ultrasonic Thickness Gauge for Plastic
Thickness Gauge 0.63 mm to 22.8 mm | 35RDC
Thickness Gauge Range up to 25.4 mm | Magna-Mike 8600
Thickness Gauge 0.080 mm to 635 mm | 45MG
Thickness Gauge 0.08 mm to 635 mm | 39DL PLUS
X-Ray Fluorescence Analysis/Thickness Gauges XRF XDL
MPOR and MPOR-FP Coating thickness gauges
Single-sided Thickness Gauge
Confocal Distance / Thickness Gauge
Ultrasonic Thickness Gauges | TM8812
Coil Thickness Measurement | Thickness Gauge
Ultrasonic Thickness Gauge | MT180
Ultrasonic Thickness Gauge | MT150
Thru-Paint & Ultrasonic Thickness Gauge | UM-1D
Coating Thickness Gauge | MCT200
New Ultrasonic Coating Thickness Gauge | QuintSonic 7
Ultrasonic Thickness Gauge | CTS-30A/CTS-30B
Ultrasonic Thickness Gauge | SIUI CTS-49 & CTS-59
Distance & Thickness Measurement |confocalDT 2471 HS | Thickness Gauge
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product