Evident Ultrasonic Flaw Detector 3x Faster ...
Evident - Ultrasonic Flaw Detector 3x Faster TFM Acquisition Rate | OmniScan X4
Detect and interpret challenging flaws and identify damage earlier with the powerful, yet portable OmniScan™ X4 multitechnology flaw detector.
Exploit its versatile PA, faster TFM, innovative PCI, and efficient twin TFM/PCI to perform rapid and reliable inspections of welds and components.
Be Ready for What’s Next: OmniScan X4 Flaw Detector
A portable yet powerful solution, the speed and versatility of the OmniScan™ X4 multitechnology series boosts your productivity while increasing confidence in your assessments. Exploit its advanced phased array capabilities, efficient total focusing method (TFM), and innovative phase coherence imaging (PCI) to detect and interpret challenging flaws and secure the integrity of your assets by identifying damage earlier.
Proven to Perform, Trusted to Deliver
Each OmniScan X4 unit is a complete multitechnology inspection toolbox, enabling you to exploit multiple ultrasonic testing techniques. Leverage its detection and measurement capabilities to accurately identify and evaluate the severity of damage before it becomes critical, protecting welds, components, and assets most susceptible to cracking or corrosion.
Assess with Certainty Using PCI
Eliminate doubt through phase coherence imaging’s capacity to detect and accentuate historically difficult-to-detect flaws, including hook cracks and stress corrosion cracking (SCC). Use PCI to clearly distinguish individual flaws in colonies of fine cracks and characterize them with certainty.
3x Faster TFM Acquisition Rate
Obtain crisp TFM imaging at up to three times faster* acquisition rates than the predecessor model (X3 64) thanks to the OmniScan X4 series’ improved processing power. Exploit the increased speed and 128-element capacity of the OmniScan X4 64:128PR unit to perform TFM inspections with extended focusing capabilities.
*Achieving this speed depends on the configuration and the use of sparse firing. Inquire for more details.
Gain Instant Insights and Eliminate Inefficiency
Twice the Confidence with Twin TFM and PCI
Exploit the individual attributes of PCI and TFM to thoroughly investigate the volume of welds from both sides simultaneously. Use two probes to scan the weld in one pass, displaying TFM and PCI results to compare, measure, and confirm your characterization of indications with efficiency and precision.
Engineered for Speed and Simplicity
Performing phased array, TOFD, TFM, and PCI is straightforward and intuitive on the OmniScan X4 series. Inspectors of any experience level can exploit these techniques with increased efficiency and more confidence utilizing the simple step-by-step scan plan and application presets.
Convenient Application Presets
Improve the learning curve and increase the reliability and consistency of inspections between operators with the OmniScan X4 application presets. Even low-level users and new users can produce an optimal PA or PCI configuration within minutes.
With options for corrosion and composite inspections, these preprogrammed parameters simplify scanning setups using HydroFORM™, FlexoFORM™, and RollerFORM™ scanners, and you can adjust the settings as needed.
Ease Complex Configurations
The OmniScan X4 scan plan’s intuitive step-by-step 3D graphics ease your inspection setups, from the most basic to the most complex.
When setting up your raster scan plan, the scan axes can be customed named and you can create a datum reference point relative to the asset. These real-world references as well as the true orientation correction, greatly ease the creation of an intuitive schematic representation of the inspection data for your report.
Applications
Choose the Right Model for Your Application
Each model of the OmniScan X4 series has the capability to drive probes with a certain number of elements, offering varying focusing capabilities for different materials and thicknesses. Here is an overview of the types of applications that the four models are most proficient at performing. Contact us or your Evident representative for more details.
| 16:64PR | 16:128PR | 32:128PR | 64:128PR |
|
Excels at the following applications:
|
Excellent mid-range model for:
|
Enables high-productivity weld inspection including coarse-grained materials:
|
Higher-productivity weld inspection in thicker, coarse-grained materials:
|
HTHA Inspection Solutions
OmniScan™ X4 Phased Array Flaw Detector with TFM and PCI
Detect and Define Smaller HTHA Cracks
Detecting HTHA early and reliably is so challenging that multiple inspection methods are often used in conjunction to maximize the probability of detection. Time-of-flight diffraction (TOFD), along with focused phased array (PA) and the total focusing method (TFM), especially using Dual Linear Array™ (DLA) probes, have shown to be particularly effective inspection techniques for this application.
OmniScan™ X4 flaw detector fully supports these methods, as well as innovative phase coherence imaging (PCI), which enhances small flaws and crack tips. OmniScan X4 instruments also offer a variety of onboard software tools to ease your setup and analysis workflow.
- Integrated DLA probe configuration and scanner configuration
- High-resolution TFM images (up to 1024 × 1024 points)
- Software tools to optimize the TFM inspection process, from setup to analysis (scan plan with AIM model, automatic TCG, sparse firing, soft gain and palette slider, live TFM envelope and image filters, gates, and alarms)
- 64-element TFM aperture and 128-element extended TFM aperture (OmniScan X4 64:128PR model)
- Phase coherence imaging to enhance small defects and crack tips (all OmniScan X4 units)
- Acquire up to 8 TOFD and phased array groups simultaneously for efficient screening
- Acquire and display up to 4 TFM and PCI groups at once
- Plane wave imaging (PWI) available with TFM and PCI (using the OmniScan X4 unit with linear array probes)
Weld Solutions
OmniScan™ X4 Phased Array Flaw Detector
Get the Most Out of Your Inspection
The Omniscan X4 flaw detector is a comprehensive multitechnology toolbox, equipped with setup, imaging, and analysis to tools that make weld inspection easier
- Do your complete setup using the intuitive onboard scan plan without having to use a PC
- Improved fast calibration
- Enhanced image resolution and geometrically correct flaw representation with multigroup total focusing method (TFM) imaging and phase coherence imaging (PCI)
- Twin TFM/PCI images the volume of welds from both sides, using two probes, displaying TFM and PCI data simultaneously on the display
- Standard PR configuration enables the use of larger apertures on dual array probes (up to 128-element extended TFM aperture with the 64:128PR model)
The OmniScan X4 flaw detector excels at a broad range of weld inspection applications, including:
- In-service and construction welding
- Pressure vessels
- Process pipes
- Boiler tubes
- Pipeline
- Wind tower
- Structural construction
- Corrosion-resistant alloys and cladded materials (austenitic, nickel, and other coarse-grained materials)
Specifications:
|
General and Enclosure |
|
|---|---|
|
Size |
335 mm × 221 mm × 151 mm (13.2 in. × 8.7 in. × 5.9 in.) |
|
Weight |
5.7 kg (with 1 battery) for model 16:64PR 5.9 kg (with 1 battery) for models 16:128PR, 32:128PR, and 64:128PR |
|
Onboard Storage |
1 TB internal SSD storage. Maximum 25 GB individual file size. Storage extensible using external USB drive |
|
Storage Devices |
SDHC and SDXC cards, or most standard USB storage devices |
|
Wireless |
Wi-Fi® 6E and Bluetooth® 5.3 onboard |
|
PAUT Connectors |
1 PA connector, 2x UT channels (2 P/R connectors each) |
|
Available Configurations and Groups |
OmniScan X4A – 64 :128PR : 8 groups OmniScan X4A – 32 :128PR : 8 groups OmniScan X4A – 16 :128PR: 8 groups OmniScan X4B – 16 :64PR: 2 groups (PA, UT, or TFM) or a specific configuration of 2 PA groups + 1 TOFD |
|
Drop Testing |
Drop-tested according to MIL-STD-810G |
|
Ingress Protection Rating |
IP65 Certified (completely protected against dust and water jets from all directions (6.3mm nozzle)) |
|
Display |
269 mm (10.6 in.) TFT LCD with resistive touch screen, 1280 × 768 pixels |
|
Battery |
2 hot-swappable Lithium-ion batteries included, 87 Wh each |
|
Battery Life |
Minimum of 5 hours (using ISO18563 standard setup parameters) |
|
Operating Temperature |
−10 to 45 °C (14 °F to 113 °F) |
|
Storage Temperature |
−20 °C to 60 °C (−4 °F to 140 °F) (with battery inside) −20 °C to 70 °C (−4 °F to 158 °F) (with no battery inside) |
|
Inputs and Outputs |
|
|---|---|
|
Ports |
2x USB 3.1, 1x video out (HDMI), 1x SDHC memory card slot, 1x communication (Ethernet) |
|
Encoders |
2-axis encoder line (quadrature or clock/direction) |
|
Digital Inputs and Outputs |
4 digital inputs (TTL), 4 digital outputs (TTL) including one reserved for acquisition on/off |
|
External DC Supply |
18 VDC, circular 2.5 mm diameter connector, center-positive |
|
General Ultrasonic Specifications |
|
|---|---|
|
Effective Digitizing Frequency |
Up to 100 MHz; User-adjustable compression factor |
|
Maximum Pulse Repetition Rate (PRF) |
Up to 20 kHz; Actual maximum PRF is often limited by physics (the time of flight required to obtain the ultrasonic signals) |
|
Maximum Number of A-Scan Data Points |
Up to 16,384 |
|
A-Scan Bit Depth |
16 bits |
|
Rectification |
RF, full wave, half wave+, half wave− |
|
Video Filtering |
Smoothing (adjusted to the probe frequency range) |
|
Filtering |
PA channel: selection of band-pass filters, high-pass filters, and averaging UT channel: selection of low-pass filters, band-pass filters, high-pass filters, and averaging |
|
Time-Corrected Gain (TCG) |
PA: 40 dB per step of min. 0.1 dB UT: 100 dB per step of min. 0.1 dB Maximum slope of 40 dB/10 ns |
|
Supported Beam Types (Groups) |
Selection of phased array ultrasonics (PAUT) beam types (linear, sectorial, and compound), single ultrasonic beam (UT), time-of-flight-diffraction ultrasonics (TOFD), total focusing method (TFM), phase coherence imaging (PCI), full matrix capture (FMC), and plane wave imaging (PWI) |
|
Raw Full Matrix Capture (FMC) Data Collection |
Available only with model 64:128PR when using the NDT Device API or the OmniScan Black Box onboard application used with external acquisition software |
|
Acoustic Specifications |
|||
|---|---|---|---|
|
|
PA Channel |
UT Channels |
|
|
Certification |
Calibration Certification |
ISO 18563-1:2022 |
EN22232:2020 |
|
Pulse Width |
Adjustable from 30 ns to 1000 ns; resolution of 5 ns (half period of bipolar pulse or duration of negative pulse) |
Adjustable from 30 ns to 1,000 ns; resolution of 2.5 ns |
|
|
Pulse Shape |
Bipolar negative-positive square pulse |
Negative square pulse |
|
|
Receiver |
Gain Range |
0 dB to 80 dB; maximum input signal 900 mVp-p (full-screen height). |
0 dB to 120 dB; maximum input signal 30 Vp-p (full-screen height) |
|
System Bandwidth |
0.2 MHz to 26.5 MHz |
0.25 MHz to 28.5 MHz |
|
PAUT Specifications |
||||
|---|---|---|---|---|
|
OmniScan X4 Variant |
64:128PR |
32:128PR |
16:128PR |
16:64PR |
|
Maximum Pulsing Aperture |
64 |
32 |
16 |
16 |
|
Maximum Number of Receiving Channels |
128 |
128 |
128 |
64 |
|
Number of Focal Laws |
1024 maximum total (512 maximum per group) |
|
FMC / TFM / PCI / PWI Specifications |
||||
|---|---|---|---|---|
|
OmniScan X4 Variant |
64:128PR |
32:128PR |
16:128PR |
16:64PR |
|
Maximum Extended Aperture (FMC) |
128 |
64 |
32 |
32 |
|
Maximum Aperture (PWI) |
64 |
32 |
16 |
16 |
|
Maximum TFM or PCI Groups |
4 |
4 |
4 |
2 |
|
Live TFM Envelope |
Yes – Actual Hilbert Transform |
|||
|
Image Resolution |
Up to 1024 × 1024 (1M points) for each TFM or PCI wave set |
|||
|
FMC Supported Wave Sets (TFM or PCI Modes) |
Pulse-Echo: L-L, T-T, and TT-TT Self-Tandem: TT-T, TT-TTT, LL-L, LT-T, TL-T, TT-L, and TL-L |
|||
|
PWI Supported Wave Sets (TFM or PCI Modes) |
Pulse-Echo: L-L and T-T |
To contact Evident Australia about Evident Ultrasonic Flaw Detector 3x Faster TFM Acquisition Rate | OmniScan X4 use Get a quote.
Exploit its versatile PA, faster TFM, innovative PCI, and efficient twin TFM/PCI to perform rapid and reliable inspections of welds and components.
Be Ready for What’s Next: OmniScan X4 Flaw Detector
A portable yet powerful solution, the speed and versatility of the OmniScan™ X4 multitechnology series boosts your productivity while increasing confidence in your assessments. Exploit its advanced phased array capabilities, efficient total focusing method (TFM), and innovative phase coherence imaging (PCI) to detect and interpret challenging flaws and secure the integrity of your assets by identifying damage earlier.
Proven to Perform, Trusted to Deliver
Each OmniScan X4 unit is a complete multitechnology inspection toolbox, enabling you to exploit multiple ultrasonic testing techniques. Leverage its detection and measurement capabilities to accurately identify and evaluate the severity of damage before it becomes critical, protecting welds, components, and assets most susceptible to cracking or corrosion.
Assess with Certainty Using PCI
Eliminate doubt through phase coherence imaging’s capacity to detect and accentuate historically difficult-to-detect flaws, including hook cracks and stress corrosion cracking (SCC). Use PCI to clearly distinguish individual flaws in colonies of fine cracks and characterize them with certainty.
3x Faster TFM Acquisition Rate
Obtain crisp TFM imaging at up to three times faster* acquisition rates than the predecessor model (X3 64) thanks to the OmniScan X4 series’ improved processing power. Exploit the increased speed and 128-element capacity of the OmniScan X4 64:128PR unit to perform TFM inspections with extended focusing capabilities.
*Achieving this speed depends on the configuration and the use of sparse firing. Inquire for more details.
Gain Instant Insights and Eliminate Inefficiency
Twice the Confidence with Twin TFM and PCI
Exploit the individual attributes of PCI and TFM to thoroughly investigate the volume of welds from both sides simultaneously. Use two probes to scan the weld in one pass, displaying TFM and PCI results to compare, measure, and confirm your characterization of indications with efficiency and precision.
Engineered for Speed and Simplicity
Performing phased array, TOFD, TFM, and PCI is straightforward and intuitive on the OmniScan X4 series. Inspectors of any experience level can exploit these techniques with increased efficiency and more confidence utilizing the simple step-by-step scan plan and application presets.
Convenient Application Presets
Improve the learning curve and increase the reliability and consistency of inspections between operators with the OmniScan X4 application presets. Even low-level users and new users can produce an optimal PA or PCI configuration within minutes.
With options for corrosion and composite inspections, these preprogrammed parameters simplify scanning setups using HydroFORM™, FlexoFORM™, and RollerFORM™ scanners, and you can adjust the settings as needed.
Ease Complex Configurations
The OmniScan X4 scan plan’s intuitive step-by-step 3D graphics ease your inspection setups, from the most basic to the most complex.
When setting up your raster scan plan, the scan axes can be customed named and you can create a datum reference point relative to the asset. These real-world references as well as the true orientation correction, greatly ease the creation of an intuitive schematic representation of the inspection data for your report.
Applications
Choose the Right Model for Your Application
Each model of the OmniScan X4 series has the capability to drive probes with a certain number of elements, offering varying focusing capabilities for different materials and thicknesses. Here is an overview of the types of applications that the four models are most proficient at performing. Contact us or your Evident representative for more details.
| 16:64PR | 16:128PR | 32:128PR | 64:128PR |
|
Excels at the following applications:
|
Excellent mid-range model for:
|
Enables high-productivity weld inspection including coarse-grained materials:
|
Higher-productivity weld inspection in thicker, coarse-grained materials:
|
HTHA Inspection Solutions
OmniScan™ X4 Phased Array Flaw Detector with TFM and PCI
Detect and Define Smaller HTHA Cracks
Detecting HTHA early and reliably is so challenging that multiple inspection methods are often used in conjunction to maximize the probability of detection. Time-of-flight diffraction (TOFD), along with focused phased array (PA) and the total focusing method (TFM), especially using Dual Linear Array™ (DLA) probes, have shown to be particularly effective inspection techniques for this application.
OmniScan™ X4 flaw detector fully supports these methods, as well as innovative phase coherence imaging (PCI), which enhances small flaws and crack tips. OmniScan X4 instruments also offer a variety of onboard software tools to ease your setup and analysis workflow.
- Integrated DLA probe configuration and scanner configuration
- High-resolution TFM images (up to 1024 × 1024 points)
- Software tools to optimize the TFM inspection process, from setup to analysis (scan plan with AIM model, automatic TCG, sparse firing, soft gain and palette slider, live TFM envelope and image filters, gates, and alarms)
- 64-element TFM aperture and 128-element extended TFM aperture (OmniScan X4 64:128PR model)
- Phase coherence imaging to enhance small defects and crack tips (all OmniScan X4 units)
- Acquire up to 8 TOFD and phased array groups simultaneously for efficient screening
- Acquire and display up to 4 TFM and PCI groups at once
- Plane wave imaging (PWI) available with TFM and PCI (using the OmniScan X4 unit with linear array probes)
Weld Solutions
OmniScan™ X4 Phased Array Flaw Detector
Get the Most Out of Your Inspection
The Omniscan X4 flaw detector is a comprehensive multitechnology toolbox, equipped with setup, imaging, and analysis to tools that make weld inspection easier
- Do your complete setup using the intuitive onboard scan plan without having to use a PC
- Improved fast calibration
- Enhanced image resolution and geometrically correct flaw representation with multigroup total focusing method (TFM) imaging and phase coherence imaging (PCI)
- Twin TFM/PCI images the volume of welds from both sides, using two probes, displaying TFM and PCI data simultaneously on the display
- Standard PR configuration enables the use of larger apertures on dual array probes (up to 128-element extended TFM aperture with the 64:128PR model)
The OmniScan X4 flaw detector excels at a broad range of weld inspection applications, including:
- In-service and construction welding
- Pressure vessels
- Process pipes
- Boiler tubes
- Pipeline
- Wind tower
- Structural construction
- Corrosion-resistant alloys and cladded materials (austenitic, nickel, and other coarse-grained materials)
Specifications:
|
General and Enclosure |
|
|---|---|
|
Size |
335 mm × 221 mm × 151 mm (13.2 in. × 8.7 in. × 5.9 in.) |
|
Weight |
5.7 kg (with 1 battery) for model 16:64PR 5.9 kg (with 1 battery) for models 16:128PR, 32:128PR, and 64:128PR |
|
Onboard Storage |
1 TB internal SSD storage. Maximum 25 GB individual file size. Storage extensible using external USB drive |
|
Storage Devices |
SDHC and SDXC cards, or most standard USB storage devices |
|
Wireless |
Wi-Fi® 6E and Bluetooth® 5.3 onboard |
|
PAUT Connectors |
1 PA connector, 2x UT channels (2 P/R connectors each) |
|
Available Configurations and Groups |
OmniScan X4A – 64 :128PR : 8 groups OmniScan X4A – 32 :128PR : 8 groups OmniScan X4A – 16 :128PR: 8 groups OmniScan X4B – 16 :64PR: 2 groups (PA, UT, or TFM) or a specific configuration of 2 PA groups + 1 TOFD |
|
Drop Testing |
Drop-tested according to MIL-STD-810G |
|
Ingress Protection Rating |
IP65 Certified (completely protected against dust and water jets from all directions (6.3mm nozzle)) |
|
Display |
269 mm (10.6 in.) TFT LCD with resistive touch screen, 1280 × 768 pixels |
|
Battery |
2 hot-swappable Lithium-ion batteries included, 87 Wh each |
|
Battery Life |
Minimum of 5 hours (using ISO18563 standard setup parameters) |
|
Operating Temperature |
−10 to 45 °C (14 °F to 113 °F) |
|
Storage Temperature |
−20 °C to 60 °C (−4 °F to 140 °F) (with battery inside) −20 °C to 70 °C (−4 °F to 158 °F) (with no battery inside) |
|
Inputs and Outputs |
|
|---|---|
|
Ports |
2x USB 3.1, 1x video out (HDMI), 1x SDHC memory card slot, 1x communication (Ethernet) |
|
Encoders |
2-axis encoder line (quadrature or clock/direction) |
|
Digital Inputs and Outputs |
4 digital inputs (TTL), 4 digital outputs (TTL) including one reserved for acquisition on/off |
|
External DC Supply |
18 VDC, circular 2.5 mm diameter connector, center-positive |
|
General Ultrasonic Specifications |
|
|---|---|
|
Effective Digitizing Frequency |
Up to 100 MHz; User-adjustable compression factor |
|
Maximum Pulse Repetition Rate (PRF) |
Up to 20 kHz; Actual maximum PRF is often limited by physics (the time of flight required to obtain the ultrasonic signals) |
|
Maximum Number of A-Scan Data Points |
Up to 16,384 |
|
A-Scan Bit Depth |
16 bits |
|
Rectification |
RF, full wave, half wave+, half wave− |
|
Video Filtering |
Smoothing (adjusted to the probe frequency range) |
|
Filtering |
PA channel: selection of band-pass filters, high-pass filters, and averaging UT channel: selection of low-pass filters, band-pass filters, high-pass filters, and averaging |
|
Time-Corrected Gain (TCG) |
PA: 40 dB per step of min. 0.1 dB UT: 100 dB per step of min. 0.1 dB Maximum slope of 40 dB/10 ns |
|
Supported Beam Types (Groups) |
Selection of phased array ultrasonics (PAUT) beam types (linear, sectorial, and compound), single ultrasonic beam (UT), time-of-flight-diffraction ultrasonics (TOFD), total focusing method (TFM), phase coherence imaging (PCI), full matrix capture (FMC), and plane wave imaging (PWI) |
|
Raw Full Matrix Capture (FMC) Data Collection |
Available only with model 64:128PR when using the NDT Device API or the OmniScan Black Box onboard application used with external acquisition software |
|
Acoustic Specifications |
|||
|---|---|---|---|
|
|
PA Channel |
UT Channels |
|
|
Certification |
Calibration Certification |
ISO 18563-1:2022 |
EN22232:2020 |
|
Pulse Width |
Adjustable from 30 ns to 1000 ns; resolution of 5 ns (half period of bipolar pulse or duration of negative pulse) |
Adjustable from 30 ns to 1,000 ns; resolution of 2.5 ns |
|
|
Pulse Shape |
Bipolar negative-positive square pulse |
Negative square pulse |
|
|
Receiver |
Gain Range |
0 dB to 80 dB; maximum input signal 900 mVp-p (full-screen height). |
0 dB to 120 dB; maximum input signal 30 Vp-p (full-screen height) |
|
System Bandwidth |
0.2 MHz to 26.5 MHz |
0.25 MHz to 28.5 MHz |
|
PAUT Specifications |
||||
|---|---|---|---|---|
|
OmniScan X4 Variant |
64:128PR |
32:128PR |
16:128PR |
16:64PR |
|
Maximum Pulsing Aperture |
64 |
32 |
16 |
16 |
|
Maximum Number of Receiving Channels |
128 |
128 |
128 |
64 |
|
Number of Focal Laws |
1024 maximum total (512 maximum per group) |
|
FMC / TFM / PCI / PWI Specifications |
||||
|---|---|---|---|---|
|
OmniScan X4 Variant |
64:128PR |
32:128PR |
16:128PR |
16:64PR |
|
Maximum Extended Aperture (FMC) |
128 |
64 |
32 |
32 |
|
Maximum Aperture (PWI) |
64 |
32 |
16 |
16 |
|
Maximum TFM or PCI Groups |
4 |
4 |
4 |
2 |
|
Live TFM Envelope |
Yes – Actual Hilbert Transform |
|||
|
Image Resolution |
Up to 1024 × 1024 (1M points) for each TFM or PCI wave set |
|||
|
FMC Supported Wave Sets (TFM or PCI Modes) |
Pulse-Echo: L-L, T-T, and TT-TT Self-Tandem: TT-T, TT-TTT, LL-L, LT-T, TL-T, TT-L, and TL-L |
|||
|
PWI Supported Wave Sets (TFM or PCI Modes) |
Pulse-Echo: L-L and T-T |
To contact Evident Australia about Evident Ultrasonic Flaw Detector 3x Faster TFM Acquisition Rate | OmniScan X4 use Get a quote.
Evident’s OmniScan X4 is a portable ultrasonic flaw detector for inspecting welds and components using several testing methods. Phase coherence imaging (PCI) highlights hard-to-detect flaws, including hook cracks and stress corrosion cracking, so inspectors can separate individual flaws in fine-crack colonies. For weld inspections, twin TFM/PCI uses two probes to scan both sides in one pass and display results for comparison.
- TFM acquisition: up to 3x faster than X3 64 (configuration and sparse-firing dependent)
- 64:128PR supports a 64-element pulsing aperture and 128 receiving channels
- Up to 1024 x 1024 points per TFM or PCI wave set
- Two 87 Wh hot-swappable lithium-ion batteries included
- Minimum 5 hours’ battery life using ISO 18563 standard setup parameters
Source: listing by Evident Australia on IndustrySearch · Updated 1 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Evident Australia on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Benchtop XRF Analyzer | Evident Vanta GX
Thickness Gauge 0.08 mm to 635 mm | 39DL PLUS
Thickness Gauge 0.080 mm to 635 mm | 45MG
Handheld XRF Analyzer IP54 Rated | Vanta Element
Handheld XRF Analyzer 55 kV Tungsten | Vanta Max
Thickness Gauge Range up to 25.4 mm | Magna-Mike 8600
Thickness Gauge 0.50 mm to 635 mm | 27MG
Thickness Gauge 0.63 mm to 22.8 mm | 35RDC
Thickness Gauge High-resolution Touch Screen | 72DL PLUS
Ultrasonic Flaw Detector IP66/67 | EPOCH 650
Ultrasonic Flaw Detector IP65/67 | EPOCH 6LT
Ultrasonic Flaw Detector 8.4-inch Touch Screen | OmniScan SX
Eddy Current Sensor 16-Pin | Conductivity Probes and Standard
Handheld XRF Analyzer IP55/IP54 | Vanta Series
Video Borescopes 20-30 Meter Scope | IPLEX GAir
Video Borescopes 186-Minute Battery Life | IPLEX GX/GT
Video Borescopes Interchangeable Scope | IPLEX NX
Video Borescopes IP65 | IPLEX G Lite/G Lite-W
Video Borescopes 1.8 mm Rigid Scope | IPLEX TX II
Transducer Cables | Evident Australia
Ultrasonic Flaw Detector 8.4-inch Touch Screen | OmniScan SX
Ultrasonic Flaw Detector IP65/67 | EPOCH 6LT
Ultrasonic Flaw Detector IP66/67 | EPOCH 650
Ultrasonic Flaw Detector 128-element Aperture TFM | OmniScan X3
Flaw Detectors | Sitescan D Series
Headlamp Kit | Spectrolin EagleEye | Flaw Detector
Digital Ultrasonic Flaw Detector | Rail Rover
Digital Ultrasonic Flaw Detector for Rail Weld Joint
Phased Array & TOFD Ultrasonic Flaw Detector | SUPOR
Phased Array & TOFD Sonatest | VEO+ | Flaw Detector
Flaw Detector | Sonatest Masterscan D70
Ultrasonic Flooded Member / Flaw Detector (FMD) | Cygnus Instruments
Sonatest Prisma Ultrasonic Flaw Detector
Digital Ultrasonic Flaw Detector | Tru-Test
Digital Ultrasonic Flaw Detector | Tru-Sonic
Veo3 Phased Array Ultrasonic Flaw Detector
Sonatest WAVE Ultrasonic Flaw Detector
Sonatest Sitescan D-50 Digital Ultrasonic Flaw Detector
Echo Pro Ultrasonic Flaw Detector
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product