Australia's #1 industrial directory for equipment & suppliers

Hazardous Area Cable Glands | SS2K

Supplier: Gerard Lighting

Hazardous Area Cable Glands, CMP Type SS2K Tri-Star Triple Certified Flameproof (Type ‘d’), Increased Safety (Type ‘e’) and Restricted Breathing (Type ‘nR’) indoor and outdoor cable gland for use in Zone 1, Zone 2, Zone 21 and Zone 22 hazardous areas with un-armoured cables.

CONTACT THIS SUPPLIER TO FIND OUT MORE

Hazardous Area Cable Glands | SS2K

This cable gland provides a flameproof seal on the cable inner sheath (or outer sheath of single sheathed cable) and a secondary environmental seal on the cable outer sheath. This cable gland can also be used with braided cables where the sealing is made on the cable overall diameter, when this arrangement is permitted by the prevailing installation code of practice, and the metallic braid is earthed inside the equipment.

This product provides full compatibility with restricted breathing equipment and affords extra stability and superior resistance to cable pull out. The CMP SS2K Tri-Star

Cable Gland is suitable for use with all forms of equipment protection permitted in Zone 1, Zone 2, Zone 21 & Zone 22 provided always that the prevailing code of practice for selection and installation is observed, e.g. IEC 60079-14.

Technical Data

  • Type
    • SS2K
  • Design Specification
    • BS 6121:Part 1:1989, EN 50262:1999
  • ATEX Certification
    • SIRA06ATEX1097X
  • Code of Protection Category
    • ATEX II 2 GD Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66, -Equipment Zone 1, Zone 2, Zone 21, & Zone 22 -Gas Groups IIA,IIB, IIC, ATEX IM2, Ex d I, Ex e I
  • Compliance Standards
    • EN 60079-0:2004, EN 60079-1:2004, EN 60079-7:2003, EN 60079-15:2003, EN 61241-0:2004, EN 61241-1:2004
  • IECEx Approval Number
    • IECEx SIR 06.0041X
  • Code of Protection Category
    • Ex d IIC, Ex e II, Ex nR II, Ex tD A21 IP66, Ex d I, Ex e I
  • Compliance Standards
    • IEC 60079-0:2004, IEC 60079-1:2003, IEC 60079-7:2001, IEC 60079-15:2005, IEC 61241-0:2004, IEC 61241-1:2004
  • Lloyds Approval Number
    • 01/00172
  • DNV Approval Number
    • E-6157
  • ABS Approval Number
    • 01-LD 234401-PDA
  • Continuous Operating Temperature
    • -60°C to +130°C
  • Ingress Protection Rating
    • IP66, IP67, IP68
  • Ingress Protection Document
    • 5046 C549K
  • Deluge Protection Compliance
    • DTS01 : 91
  • Deluge Protection Document
    • 5046 C549K-D
  • Cable Gland Material
    • Electroless Nickel Plated Brass, Aluminium, Stainless Steel
  • Seal Material
    • CMP SOLO LSF Thermoplastic Elastomer
  • Cable Type
    • Unarmoured & Braided
  • Sealing Technique
    • CMP Displacement Seal
  • Sealing Area(s)
    • Cable Inner Bedding and Cable Outer Sheath, or Double Seal on Cable Outer Sheath
  • Optional Accessories
    • Locknut
    • Shroud
    • Entry Thread Seal
    • Serrated Washer
    • Earth Tag
    • Adaptor/Reducer

CONTACT THIS SUPPLIER TO FIND OUT MORE

Showcase your business!

Connect with 600,000 industrial buyers annually

Learn more