Test & Tag Solutions | SAFE T CHECK Pro ...
Test & Tag Solutions | SAFE T CHECK Pro Logger II
The continual evolution of the SAFETCHECK Pro Logger II ensures the latest Technology provides the user with features unique amongst Portable Appliance Testers.
All new 3 Phase Test Option for the Pro Logger II Portable Appliance Tester:
- Tests 20A & 32A appliances (two sets of plugs 1. and sockets);
- Monitors the combined leakage current from all phases and the resistance in the earth conductor;
- Senses if the Appliance Under Test is running;
- Reports excessive leakage as a FAIL; and
- Logs the test result (PASS or FAIL) with the measured value of Leakage Current and Earth Resistance.
- Tests 20A and 32A 3 phase appliances.
- Upgrade available for your existing Pro Logger II
- Designed and manufactured in Australia
Check Connect:
This unique feature ensures a correct connection every time,where other testers may incorrectly pass appliances.
Dual Test Plugs:
No extra adaptors required
Separate Run Test Socket:
Provides three extra levels of operator safety
RCD/Ext. Lead Test (Option):
Combines an Extension Lead and RCD test in one
Other Appliance Menu:
Provides test parameters for many appliances that can't normally be tested, such as EPOD units which have LED or Neon Indicator Lights.
Mains Check
Ensures a safe correctly wired mains supply
Data Logging:
Fully integrated Data Logger provided with PC Interface software at no extra cost
The Pro Logger II has been designed and manufactured in Australia to test electrical appliances, ensuring they comply with the requirements of the current Australian and New Zealand standard AS/NZS 3760 (In-service safety Inspection and testing of electrical Equipment).
Simple Operation
Connect the appliance, select the Appliance Type, start the test. The Result is Pass/Fail.
Featuring Check Connect, unique to the Pro Logger II. Ensures that any Class II appliance is correctly connected to the PAT, resulting in a PASS or FAIL you can trust. Many other testers will not do this, and will incorrectly pass Class I appliances tested as Class II. This can result in a faulty Class I appliance being given a pass.
- All tests are completed in Approximately 4 seconds.
- All electrical thresholds are preset for the selected appliance.
- All requirements of the standard Are satisfied prior to passing an Appliance.
- Ensures the safety of both the operator and appliance at all times.
Additional benefits
- The Pro Logger II is the only PAT Tester to use a stainless steel cloak, incorporating the Check Connect feature to ensure a thorough insulation resistance test and operator safety
- Conducts a leakage current test (Run test) to measure an appliances leakage current (if mains power is required to operate the appliances On/Off switch). For safety, the Pro Logger II features 2 sockets.
- Data Logger stores up to 2000 records
- New stainless steel cloak is standard
- High current 10/25A earth tester (Option)
- RCD tester (tests RCD as well as ext. lead) (Option)
- Rugged, water and dust proof case with accessory compartment
- An LCD display clearly indicates Pass/Fail and details of a fault
- Has pre-programmed test parameters for specific appliances (E.g. mineral insulated metal sheathed heaters, EPODS, etc)
- Light weight (approximately 3kg)
- Has several safety features to ensure operator safety from electric shock
- Records and displays measured values for insulation resistance, earth resistance and leakage current
- Electrical continuity test for Resistance Active-Neutral
- Earth continuity <= 1.0 Ohm (test current @ 200mA)
- Insulation resistance >=1M Ohm (test voltage 500V DC)
- Connection polarity Tests transposition of Active-Neutral
Run test (leakage current tests)
- Separate 15A Run Socket for user safety (no switched earth)
- 240V AC @ 15A for the duration of the test
Data logger
- Complete user control of Data
- Logging functions:
- Logging can be switched on/off
- Fields can be switched on/off
- Logging functions:
- Uses Keyboard and Scanner
- Actual Time & Date stored with each test record
- Stores 500, 1000 or 2000 records
- Records are easily uploaded to a PC
- Records are always appended to memory and to PC's data file
- Records measured values
- Frequency of Test recorded with next test date calculated
Display / Indicators
- LCD 128 x 64 pixels
- Indicates Pass/Fail
- Suggests possible fault conditions
- Helpful user information
- LED's - Red (Fail/Reset) and Green (Start/Ready)
- Audible alarm
Power requirements
240V +/-10% 50Hz. (The mains power outlet supplying the STC is checked for both the existence of an Earth and Active- Neutral transposition)
Test Inlets
- Flush mounted test plugs (Both IEC and standard 240V plugs - protected from accidental application of 240V mains)
- Separate run test socket for safety (Protects the user from a failed switched earth)
Operating instructions
The Pro Logger II is intuitive to operate together with on screen prompts and clearly labelled switches. Step by step instructions are also outlined in the instruction manual provided.
Mechanical
- The Pro Logger II Case
- Pelican Protector Case™
- Yellow (safety alert)
- Rugged, water tight & dust proof
- Stainless steel hinges
- Dimensions: 340mm x 295mm X 153mm
- Weight approx. 3kg Front panel / key pad
- LEXAN insulated membrane
- Finish antiglare polyester
- Key operations > 1 million
Included Accessories
- Downloader CD & Manuals
- Mains power cord
- Return lead and clamp
- Stainless steel cloak
- Calibration Certificate
- Computer Interface Cable
Options
- RCD Tester (10mA & 30mA Portable & Fixed RCDs c/w integrated Isolation Transformer)
- Rechargeable, Internal Battery Supply (Battery Life > 7 hrs For Insulation Resistance tests Only; under normal operating Conditions) †
- High Current Earth Tester (200mA Continuity, 10A routine and 25A type Tests)
- Scanner
- Keyboard
- Upgrade to 1000 or 2000 stored Records (Default 500)
- Large stainless steel cloak
- Test tags
- Removable lid
Click here to view product brochure
To contact Measure-Tech Australia about Test & Tag Solutions | SAFE T CHECK Pro Logger II use Get a quote.
All new 3 Phase Test Option for the Pro Logger II Portable Appliance Tester:
- Tests 20A & 32A appliances (two sets of plugs 1. and sockets);
- Monitors the combined leakage current from all phases and the resistance in the earth conductor;
- Senses if the Appliance Under Test is running;
- Reports excessive leakage as a FAIL; and
- Logs the test result (PASS or FAIL) with the measured value of Leakage Current and Earth Resistance.
- Tests 20A and 32A 3 phase appliances.
- Upgrade available for your existing Pro Logger II
- Designed and manufactured in Australia
Check Connect:
This unique feature ensures a correct connection every time,where other testers may incorrectly pass appliances.
Dual Test Plugs:
No extra adaptors required
Separate Run Test Socket:
Provides three extra levels of operator safety
RCD/Ext. Lead Test (Option):
Combines an Extension Lead and RCD test in one
Other Appliance Menu:
Provides test parameters for many appliances that can't normally be tested, such as EPOD units which have LED or Neon Indicator Lights.
Mains Check
Ensures a safe correctly wired mains supply
Data Logging:
Fully integrated Data Logger provided with PC Interface software at no extra cost
The Pro Logger II has been designed and manufactured in Australia to test electrical appliances, ensuring they comply with the requirements of the current Australian and New Zealand standard AS/NZS 3760 (In-service safety Inspection and testing of electrical Equipment).
Simple Operation
Connect the appliance, select the Appliance Type, start the test. The Result is Pass/Fail.
Featuring Check Connect, unique to the Pro Logger II. Ensures that any Class II appliance is correctly connected to the PAT, resulting in a PASS or FAIL you can trust. Many other testers will not do this, and will incorrectly pass Class I appliances tested as Class II. This can result in a faulty Class I appliance being given a pass.
- All tests are completed in Approximately 4 seconds.
- All electrical thresholds are preset for the selected appliance.
- All requirements of the standard Are satisfied prior to passing an Appliance.
- Ensures the safety of both the operator and appliance at all times.
Additional benefits
- The Pro Logger II is the only PAT Tester to use a stainless steel cloak, incorporating the Check Connect feature to ensure a thorough insulation resistance test and operator safety
- Conducts a leakage current test (Run test) to measure an appliances leakage current (if mains power is required to operate the appliances On/Off switch). For safety, the Pro Logger II features 2 sockets.
- Data Logger stores up to 2000 records
- New stainless steel cloak is standard
- High current 10/25A earth tester (Option)
- RCD tester (tests RCD as well as ext. lead) (Option)
- Rugged, water and dust proof case with accessory compartment
- An LCD display clearly indicates Pass/Fail and details of a fault
- Has pre-programmed test parameters for specific appliances (E.g. mineral insulated metal sheathed heaters, EPODS, etc)
- Light weight (approximately 3kg)
- Has several safety features to ensure operator safety from electric shock
- Records and displays measured values for insulation resistance, earth resistance and leakage current
- Electrical continuity test for Resistance Active-Neutral
- Earth continuity <= 1.0 Ohm (test current @ 200mA)
- Insulation resistance >=1M Ohm (test voltage 500V DC)
- Connection polarity Tests transposition of Active-Neutral
Run test (leakage current tests)
- Separate 15A Run Socket for user safety (no switched earth)
- 240V AC @ 15A for the duration of the test
Data logger
- Complete user control of Data
- Logging functions:
- Logging can be switched on/off
- Fields can be switched on/off
- Logging functions:
- Uses Keyboard and Scanner
- Actual Time & Date stored with each test record
- Stores 500, 1000 or 2000 records
- Records are easily uploaded to a PC
- Records are always appended to memory and to PC's data file
- Records measured values
- Frequency of Test recorded with next test date calculated
Display / Indicators
- LCD 128 x 64 pixels
- Indicates Pass/Fail
- Suggests possible fault conditions
- Helpful user information
- LED's - Red (Fail/Reset) and Green (Start/Ready)
- Audible alarm
Power requirements
240V +/-10% 50Hz. (The mains power outlet supplying the STC is checked for both the existence of an Earth and Active- Neutral transposition)
Test Inlets
- Flush mounted test plugs (Both IEC and standard 240V plugs - protected from accidental application of 240V mains)
- Separate run test socket for safety (Protects the user from a failed switched earth)
Operating instructions
The Pro Logger II is intuitive to operate together with on screen prompts and clearly labelled switches. Step by step instructions are also outlined in the instruction manual provided.
Mechanical
- The Pro Logger II Case
- Pelican Protector Case™
- Yellow (safety alert)
- Rugged, water tight & dust proof
- Stainless steel hinges
- Dimensions: 340mm x 295mm X 153mm
- Weight approx. 3kg Front panel / key pad
- LEXAN insulated membrane
- Finish antiglare polyester
- Key operations > 1 million
Included Accessories
- Downloader CD & Manuals
- Mains power cord
- Return lead and clamp
- Stainless steel cloak
- Calibration Certificate
- Computer Interface Cable
Options
- RCD Tester (10mA & 30mA Portable & Fixed RCDs c/w integrated Isolation Transformer)
- Rechargeable, Internal Battery Supply (Battery Life > 7 hrs For Insulation Resistance tests Only; under normal operating Conditions) †
- High Current Earth Tester (200mA Continuity, 10A routine and 25A type Tests)
- Scanner
- Keyboard
- Upgrade to 1000 or 2000 stored Records (Default 500)
- Large stainless steel cloak
- Test tags
- Removable lid
Click here to view product brochure
To contact Measure-Tech Australia about Test & Tag Solutions | SAFE T CHECK Pro Logger II use Get a quote.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Triple Level Thermal Disinfection Indicator - T.D.I.
Test & Tag Solutions | SAFE T CHECK Pro Logger II
Temperature Indicator | Thermal Disinfection | Self Adhesive Strips
Temperature Indicator | Instant Response | Digital Event | Self Adhesive Strips | Britevent
Temperature Indicator | Instant Response | Self Adhesive Strips | Britevent
Temperature Indicator | Continuous Monitoring | Instant Response | Self Adhesive Strips | BriteLine
Temperature Indicator | Self Adhesive Strips | Encapsulated
Temperature Indicator | Self Adhesive Strips | 8 Levels
Temperature Indicator | Self Adhesive Strips | Mini | 6 Levels
Temperature Indicator | Self Adhesive Strips | Dual Scale
Temperature Indicator | Self Adhesive Strips | Micro Labels | 4 Levels
Temperature Indicator | Self Adhesive Strips | 3 Levels
Temperature Indicator | Hand Hot
Temperature Indicator | Hot Temperature
Temperature Indicator | Self Adhesive Strips | Chill Checkers
Temperature Indicator | Self Adhesive Strips | 10 Levels
Temperature Indicator | Custom System
Temperature Indicator | Self Adhesive Strips | Standard
Temperature Indicator | Ink Format | Irreversible
Temperature Indicator | Paint Products | Irreversible | Single Change
Appliance tester aPAT Pro Print Pack Delta | MKII 3309
Testing & Tagging | Portable System | Test Tag
TNT+ - Safety Tester With Multiple Function Including RCD Testing
Minnesota Manual Dexterity Test | Test and Tag
Rheomat R180 Portable Viscometer | Test and Tag
Appliance Testers I Pro Logger II
Appliance Testers I Pro Logger Plus
Appliance Testers I SafeTcheck MKD II
Test & Tag Machine | TnP-500
Test & Tag Machine | 6205
Test & Tag Machine | QWERTY Keypad
Test & Tag Machine | Elite-PLUS
Test & Tag Machine | ZQ521
Test & Tag Machine | PAT and Print Kit | Clevermode
PAT Tester - Tag Printer & Scanner | TnP-500
Test & Tag Machine | Portable Appliance Tester – 10A | TnT Titan
Test & Tag Machine | Portable Appliance Tester (PAT) | UT528AU
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product