Specifications
Model | KXS7554AWHSE | |
Detection sensitivity1 | Fe sphere and SUS sphere 0.4 mm dia. | |
X-ray output | Tube voltage 30 to 80 kV, tube current 0.4 to 10.0 mA, output 350 W | |
Safety | X-ray leakage maximum 1.0 µ Sv/h or less, prevention of x-ray leakage by safety devices | |
Display | 15-inch color TFT LCD | |
Operation method | Touch panel (with touch buzzer) | |
Detection area2, 3 | Maximum width 590 mm, maximum height 250 mm (Pass height of 350 mm is available as an option.) | |
Belt width | 620 mm | |
Preset memory | 200 | |
Belt speed / Maximum product weight4 | Dry environment | 10 to 30 m/min maximum 50 kg 31 to 40 m/min maximum 40 kg 20 to 70 m/min maximum 20 kg (optional) |
Wet environment where water or oil is scattered on the conveyor | 10 to 30 m/min maximum 40 kg 31 to 35 m/min maximum 30 kg 36 to 40 m/min maximum 20 kg 20 to 60 m/min maximum 20 kg (optional) 61 to 70 m/min maximum 10 kg (optional) | |
Power requirements | 100 Vac to 120 Vac ±10% or 200 Vac to 240 Vac ±10% (However, switch the tap of a transformer), single phase, 50/60 Hz, 1.2 kVA (1.9 kVA with optional air conditioner), rush current 70 A (typ.) (40 ms or less) | |
Mass5 | 480 kg (525 kg with optional air conditioner) | |
Environmental conditions6, 7 | Temperature: 0°C to 35°C (0°C to 40°C with optional air conditioner), relative humidity: 30% to 85%, non-condensing | |
Protection class | Conveyor: IP66 Other parts: IP40 | |
Exterior | Stainless steel (SUS304) | |
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions.
2: The product size should fall bellow the detection area.
3: The entrance and exit may require covers depending on the length of a product.
4: Sum total of product weight on the conveyor.
5: Mass without option.
6: The air-conditioner option may be required depending on the operating environment.
7: The air conditioner can be used without a filter (standard); however, the filter option is recommended for use in dusty environment. When using the filter option, the temperature range in the operating environment of the x-ray system is limited.
To contact J.L.Lennard about Anritsu X-Ray Food Inspection System | Large model [XR75 series] use Get a quote.
For products in large cartons, cases and bags.
Suitable for the inspection of raw materials in receiving process as well as products in shipment process.
Specifications
Model | KXS7554AWHSE | |
Detection sensitivity1 | Fe sphere and SUS sphere 0.4 mm dia. | |
X-ray output | Tube voltage 30 to 80 kV, tube current 0.4 to 10.0 mA, output 350 W | |
Safety | X-ray leakage maximum 1.0 µ Sv/h or less, prevention of x-ray leakage by safety devices | |
Display | 15-inch color TFT LCD | |
Operation method | Touch panel (with touch buzzer) | |
Detection area2, 3 | Maximum width 590 mm, maximum height 250 mm (Pass height of 350 mm is available as an option.) | |
Belt width | 620 mm | |
Preset memory | 200 | |
Belt speed / Maximum product weight4 | Dry environment | 10 to 30 m/min maximum 50 kg 31 to 40 m/min maximum 40 kg 20 to 70 m/min maximum 20 kg (optional) |
Wet environment where water or oil is scattered on the conveyor | 10 to 30 m/min maximum 40 kg 31 to 35 m/min maximum 30 kg 36 to 40 m/min maximum 20 kg 20 to 60 m/min maximum 20 kg (optional) 61 to 70 m/min maximum 10 kg (optional) | |
Power requirements | 100 Vac to 120 Vac ±10% or 200 Vac to 240 Vac ±10% (However, switch the tap of a transformer), single phase, 50/60 Hz, 1.2 kVA (1.9 kVA with optional air conditioner), rush current 70 A (typ.) (40 ms or less) | |
Mass5 | 480 kg (525 kg with optional air conditioner) | |
Environmental conditions6, 7 | Temperature: 0°C to 35°C (0°C to 40°C with optional air conditioner), relative humidity: 30% to 85%, non-condensing | |
Protection class | Conveyor: IP66 Other parts: IP40 | |
Exterior | Stainless steel (SUS304) | |
1: Actual sensitivity depends on the physical properties of products (contents and shape) and on the environmental conditions.
2: The product size should fall bellow the detection area.
3: The entrance and exit may require covers depending on the length of a product.
4: Sum total of product weight on the conveyor.
5: Mass without option.
6: The air-conditioner option may be required depending on the operating environment.
7: The air conditioner can be used without a filter (standard); however, the filter option is recommended for use in dusty environment. When using the filter option, the temperature range in the operating environment of the x-ray system is limited.
To contact J.L.Lennard about Anritsu X-Ray Food Inspection System | Large model [XR75 series] use Get a quote.
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product