Honeywell Gas Detector | Manning EC-FX-NH3 ...
Honeywell - Gas Detector | Manning EC-FX-NH3
The Manning by Honeywell EC-FX ammonia gas detector offers tough sensors that will work in three harsh environments.
The rugged, longer lasting ammonia sensor are ideal for commercial buildings and other industrial applications, with stability you can count and low cost, the EC-FX-NH3 is the new gold standard in ammonia detection.
Featuring:
- Quick response to ammonia concentrations in low parts per million (PPM)
- Rugged construction for long-term reliability
- ATMOSTM Technology for environmental flexibility
- Stainless Steel enclosure with LCD options
- New ammonia sensor with a proprietary electrolyte
- 3 year warranty
The Ammonia sensor/transmitter has been designed for use in industrial refrigeration applications.
The EC-FX-NH3 can provide a linear 4/20 mA or Modbus RS-485 signal input into PLC’s or SCADA systems and can also be used with Honeywell controllers to create a complete gas detection system that includes visual/audible notification and relay outputs to activate ventilation.
Specifications
| Operation | In units without the optional LCD module, a group of LEDs are installed to the PCB. In units with the optional LCD, two external push buttons, “Accept” and “Scroll” are used to navigate test functions and operating modes |
| LCD Display (optional) | 2 line by 8 alpha numeric characters and continuous back |
| Output | Isolated 4/20 mA, 700 ohms max. at 24 VDC. Signal output reduces to 0.5 mA to indicate a fault condition. RS-485, Modbus RTU protocol |
| Accuracy | ±5% full scale* |
| Environmental IP Rating | Indoor use, IP 44 in accordance with EN60529:1992 |
| Humidity | 5-100% RH (condensing) |
| Temperature | -45°C to +49°C, ATMOS™ equipped enviro-adaptive technology required for refrigerated areas or outdoors |
| Sensor Pressure Limit | 0-10 PSIG |
| Storage | -40°C to +80°C, 20 to 80%RH (non condensing) |
| Communication | 4/20 mA output: #18/3 shielded cable (Belden 8770 or equal), cable runs < 1,500 ft. RS-485: for communication cable, use 24 AWG twisted pair, shielded (Belden #9841 or equal), cable runs up to 2,000 ft. For power cable use 14 AWG (Belden #5100UE or equal), cable runs up to 1,000 feet. |
| Power Source | 24 VDC, 0.5 amp max. |
| Repeatability | <10% of full scale |
| Sensor Pressure Limit | Atmospheric ±10% |
| Respnse Time (T90) | <30s for EC-FX-NH3-LR ranges 0-100 ppm, 0-200 ppm, 0-250 ppm and <75s for EC-FX-NH3-HR ranges 0-500 ppm, 0-1000 ppm |
| Ranges | 0-100 ppm, 0-200 ppm, 0-250 ppm , 0-500 ppm, 0-1000 ppm |
| Sensor Warranty | Three years from date of shipment |
| Sensor Viability Test | SensorCheck™, an internal microprocessor determines the sensor’s electrical viability every 24 hours. If the viability test fails, a 0.5 mA signal will indicate a fault. An internal light will show if a sensor is dried up or disconnected. |
| Enclosure | NEMA 1, gasketed, #16 gauge steel (standard). Stainless steel, including modified enclosures for low temperatures, ventilation ducts, etc. are available. |
| Weight | 3 lbs (1.36 kg) |
±5% of full scale range at temperature of calibration. Contact HA for additional details.
CAUTION:
EC-FX is designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, both during storage, fitting into instruments, and operation.
EC-FX is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check). Failure to carry out such tests on a regular basis may jeopardize the safety of people and property.
High Range Sensor Specifications
| OPERATING PRINCIPLE | 3-electrode electrochemical |
| MEASUREMENT RANGE | 0-500 and 0-1000 PPM NH3 |
| MAXIMUM OVERLOAD | 5000 PPM |
| LOWER DETECTION LIMIT | < 37.5 PPM |
| FILTER | None |
| SENSITIVITY | 19 ± 3 nA/PPM |
| RESPONSE TIME (T90) | < 75 s |
| BASELINE OFFSET (CLEAN AIR) | -37.5 ppm ≤ I0/S ≤ 12.5 ppm |
| ZERO SHIFT (T = [-40°C; +20°C [OR] +20°C; +50°C) | -37.5 ppm ≤ I0/S ≤ 31.25 ppm |
| ACCURACY | ± 5% full scale* |
| REPEATABILITY | < 10% of full scale |
| HOUSING MATERIAL | Polyphenylene Oxide (PPO) Noryl |
| WEIGHT | 4.5 g |
| ORIENTATION | Vertical only |
| TYPICAL APPLICATIONS | Industrial refrigeration, cold storage, and engine rooms |
| OPERATING TEMPERATURE RANGE | Continuous: -4º to 122ºF (sensor only) Storage: -58º to 122ºF (sensor only) |
| OPERATING PRESSURE RANGE | Atmospheric ± 10% |
| OPERATING HUMIDITY RANGE | 5% to 95% RH non-condensing |
| MAXIMUM AT 1000 PPM | < 0.14 mA |
| MAXIMUM O/C VOLTAGE | < 1.2 V |
| MAXIMUM S/C CURRENT | < 100 mA |
| LONG TERM OUTPUT DRIFT | < 5% per 6 months |
| EXPECTED OPERATING LIFE | Cold Storage: 4-5 years in average conditions Engine Room: 3-4 years in average conditions |
| STORAGE LIFE | 6 months in sealed container |
| STANDARD WARRANTY | Three years from date of shipment |
* ±5% of full scale range at temperature of calibration. Contact HA for additional details.
CAUTION:
EC-FX is designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided,
both during storage, fitting into instruments, and operation.
EC-FX is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the
device is confirmed by exposure to target gas (bump check). Failure to carry out such tests on a regular basis may jeopardize the safety of people and property.
PLEASE NOTE: Connection should be made via PCB sockets only. Soldering to pins will render your warranty void.
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are
strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
To contact Aegis Sales & Service about Honeywell Gas Detector | Manning EC-FX-NH3 use Get a quote.
The rugged, longer lasting ammonia sensor are ideal for commercial buildings and other industrial applications, with stability you can count and low cost, the EC-FX-NH3 is the new gold standard in ammonia detection.
Featuring:
- Quick response to ammonia concentrations in low parts per million (PPM)
- Rugged construction for long-term reliability
- ATMOSTM Technology for environmental flexibility
- Stainless Steel enclosure with LCD options
- New ammonia sensor with a proprietary electrolyte
- 3 year warranty
The Ammonia sensor/transmitter has been designed for use in industrial refrigeration applications.
The EC-FX-NH3 can provide a linear 4/20 mA or Modbus RS-485 signal input into PLC’s or SCADA systems and can also be used with Honeywell controllers to create a complete gas detection system that includes visual/audible notification and relay outputs to activate ventilation.
Specifications
| Operation | In units without the optional LCD module, a group of LEDs are installed to the PCB. In units with the optional LCD, two external push buttons, “Accept” and “Scroll” are used to navigate test functions and operating modes |
| LCD Display (optional) | 2 line by 8 alpha numeric characters and continuous back |
| Output | Isolated 4/20 mA, 700 ohms max. at 24 VDC. Signal output reduces to 0.5 mA to indicate a fault condition. RS-485, Modbus RTU protocol |
| Accuracy | ±5% full scale* |
| Environmental IP Rating | Indoor use, IP 44 in accordance with EN60529:1992 |
| Humidity | 5-100% RH (condensing) |
| Temperature | -45°C to +49°C, ATMOS™ equipped enviro-adaptive technology required for refrigerated areas or outdoors |
| Sensor Pressure Limit | 0-10 PSIG |
| Storage | -40°C to +80°C, 20 to 80%RH (non condensing) |
| Communication | 4/20 mA output: #18/3 shielded cable (Belden 8770 or equal), cable runs < 1,500 ft. RS-485: for communication cable, use 24 AWG twisted pair, shielded (Belden #9841 or equal), cable runs up to 2,000 ft. For power cable use 14 AWG (Belden #5100UE or equal), cable runs up to 1,000 feet. |
| Power Source | 24 VDC, 0.5 amp max. |
| Repeatability | <10% of full scale |
| Sensor Pressure Limit | Atmospheric ±10% |
| Respnse Time (T90) | <30s for EC-FX-NH3-LR ranges 0-100 ppm, 0-200 ppm, 0-250 ppm and <75s for EC-FX-NH3-HR ranges 0-500 ppm, 0-1000 ppm |
| Ranges | 0-100 ppm, 0-200 ppm, 0-250 ppm , 0-500 ppm, 0-1000 ppm |
| Sensor Warranty | Three years from date of shipment |
| Sensor Viability Test | SensorCheck™, an internal microprocessor determines the sensor’s electrical viability every 24 hours. If the viability test fails, a 0.5 mA signal will indicate a fault. An internal light will show if a sensor is dried up or disconnected. |
| Enclosure | NEMA 1, gasketed, #16 gauge steel (standard). Stainless steel, including modified enclosures for low temperatures, ventilation ducts, etc. are available. |
| Weight | 3 lbs (1.36 kg) |
±5% of full scale range at temperature of calibration. Contact HA for additional details.
CAUTION:
EC-FX is designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided, both during storage, fitting into instruments, and operation.
EC-FX is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the device is confirmed by exposure to target gas (bump check). Failure to carry out such tests on a regular basis may jeopardize the safety of people and property.
High Range Sensor Specifications
| OPERATING PRINCIPLE | 3-electrode electrochemical |
| MEASUREMENT RANGE | 0-500 and 0-1000 PPM NH3 |
| MAXIMUM OVERLOAD | 5000 PPM |
| LOWER DETECTION LIMIT | < 37.5 PPM |
| FILTER | None |
| SENSITIVITY | 19 ± 3 nA/PPM |
| RESPONSE TIME (T90) | < 75 s |
| BASELINE OFFSET (CLEAN AIR) | -37.5 ppm ≤ I0/S ≤ 12.5 ppm |
| ZERO SHIFT (T = [-40°C; +20°C [OR] +20°C; +50°C) | -37.5 ppm ≤ I0/S ≤ 31.25 ppm |
| ACCURACY | ± 5% full scale* |
| REPEATABILITY | < 10% of full scale |
| HOUSING MATERIAL | Polyphenylene Oxide (PPO) Noryl |
| WEIGHT | 4.5 g |
| ORIENTATION | Vertical only |
| TYPICAL APPLICATIONS | Industrial refrigeration, cold storage, and engine rooms |
| OPERATING TEMPERATURE RANGE | Continuous: -4º to 122ºF (sensor only) Storage: -58º to 122ºF (sensor only) |
| OPERATING PRESSURE RANGE | Atmospheric ± 10% |
| OPERATING HUMIDITY RANGE | 5% to 95% RH non-condensing |
| MAXIMUM AT 1000 PPM | < 0.14 mA |
| MAXIMUM O/C VOLTAGE | < 1.2 V |
| MAXIMUM S/C CURRENT | < 100 mA |
| LONG TERM OUTPUT DRIFT | < 5% per 6 months |
| EXPECTED OPERATING LIFE | Cold Storage: 4-5 years in average conditions Engine Room: 3-4 years in average conditions |
| STORAGE LIFE | 6 months in sealed container |
| STANDARD WARRANTY | Three years from date of shipment |
* ±5% of full scale range at temperature of calibration. Contact HA for additional details.
CAUTION:
EC-FX is designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapors is avoided,
both during storage, fitting into instruments, and operation.
EC-FX is designed to be used in safety critical applications. To ensure that the sensor and/or instrument in which it is used, are operating properly, it is a requirement that the function of the
device is confirmed by exposure to target gas (bump check). Failure to carry out such tests on a regular basis may jeopardize the safety of people and property.
PLEASE NOTE: Connection should be made via PCB sockets only. Soldering to pins will render your warranty void.
While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are
strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.
To contact Aegis Sales & Service about Honeywell Gas Detector | Manning EC-FX-NH3 use Get a quote.
The Honeywell Manning EC-FX-NH3 is an ammonia gas detector and transmitter that measures low-level ammonia concentrations in parts per million. ATMOS environmental-adaptive technology is required for use in refrigerated areas or outdoors. Cold-storage and engine-room operators can feed its output into PLC or SCADA systems, or use Honeywell controllers to build a complete gas-detection system.
- Isolated 4/20 mA or Modbus RTU over RS-485 output
- SensorCheck tests sensor viability every 24 hours; failure signals a 0.5 mA fault
- Optional LCD: 2 x 8 alphanumeric characters; units without it use PCB-mounted LEDs
- Three-year sensor warranty from date of shipment
- Stainless-steel enclosures, including modified versions for low temperatures and ventilation ducts, are available
Source: listing by Aegis Sales & Service on IndustrySearch · Updated 3 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Aegis Sales & Service on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Vertical Climbing System | Soll GlideLoc
Ladder Safety System | LadderLatch
Pneumatic Deadweight Tester | BGP1P
Hydraulic Deadweight Tester | BGH600DWT
Blowers and Exhausts
Confined Space Entry & Recovery
Bluetooth Enabled Gas Detector | Sensepoint XRL
Gas Detector | Manning EC-FX-NH3
Portable Five Gas Detector | BW™ Ultra
Single Gas Detector | BW™ Solo
PIRECL Point Infrared Gas Detector
LS2000 Line-Of-Sight Infrared Gas Detector (FlexSight)
Gas Analyser & Gas Detector | Kit 320
MiniRAE 3000 and ppbRAE 3000 gas detectors for VOCs
MiniRAE Lite - VOC Gas Detector for MethylBromide
Gas Detector - Everest 4gas
MiniRAE 3000 - PID Gas Detector (VOC monitor)
IR Gas Detector | GD10PE Point Extended
MiniRAE Lite VOC gas detector - Ex Demonstration
ToxiPro Personal Single Gas Detector : PID, EC, LEL
Gas Monitor | Noventis Microsense Gas Detector
Gas Detector | GDS 10 Single Point Gas Detector
Gas Detector | ALTAIR® Pro Single-Gas Detector
Gas Detector | ALTAIR® 5X Multigas Detector
Gas Detector | ALTAIR® Single-Gas Detector
4XR Gas Detector – with Bluetooth (Detector Only)
5 Personal Gas Monitor | GX-3R Pro | Gas Detector
Gas Detector | HazardWatch Fire and Gas System
Gas Detectors | Chlorine Cl2 Detector E2608
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product
