FCI Insertion Flow Switch | FlexSwitch ...
FCI - Insertion Flow Switch | FlexSwitch FLT93S
The FLT93S insertion type FlexSwitch for flow and temperature monitoring represents the first true technological breakthrough in thermal technology in over a decade.
This product was designed for heavy industrial environments including high temperature and high pressure. FCI is the only thermal manufacturer providing temperature compensation to ensure set point accuracy for process temperatures that vary up to ± 100° F.
The FLT93S is easily field-configured or factory preset, providing unparalleled flexibility, accuracy and stability for all multiple process sensing and switching requirements.
Applications:
- Pump protection
- Cooling water/heat exchangers
- Drain line flow
- Safety spray nozzle monitoring
- Oil well system testing
- Relief valve monitoring
- Venting Assurance
Specifications:
For Flow Service - Setpoint Range:
- Water-based Liquids:
0.01 to 3.0 fps [0.003 to 0.9 mps]
- Hydrocarbon-based Liquids:
0.01 to 5.0 fps [0.003 to 1.5 mps]
- Air/Gas:
0.25 to 120 sfps [0.08 to 37 smps] at standard conditions of 70° F [21.1° C] and 14.7 psia [1.013 bar(g)].
Accuracy: (whichever reading is higher)
- Liquids: ± 0.5% reading or ± 0.04 fps [± 0.012 mps]
- Gases: ± 0.5% reading or ± 2 sfps [± 0.06 nmps]
For Temperature Service:
Accuracy: ± 2° F [±1° C]
Repeatability: ± 1° F [± 0.6° C]
Response Time: As low as 3 seconds.
Enclosure: NEMA 4X/IP66 Rated. Standard: Polyester powder coated aluminum, with single 1" NPT conduit port. Optional: Stainless steel. Optional: Dual-conduit port, aluminum with 1/2" NPT or M20 metric conduit ports.
Compliances and Agency Approvals: FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro. CE mark. PED, CRN.
Meets EC directives for EMC and LVD. Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
| FM/FMc: | XP, Class 1, Div. 1 Groups B,C,D, T3A or T4 Ta =60°C DIP, Class II/III, Div. 1, Groups E,F,G, T3A or T4 Ta =60°C Nonincendive for Class I, II and III, Division 2, Groups A,B,C,D,E,F, and G, T3A or T4 -40°C =Ta=60°C; hazardous (classified) locations, indoors and outdoors. Type 4X |
| ATEX: | Integral: II 2 G Ex db IIC T4…T2 Gb II 2 D Ex tb IIIC T135°C…T300°C Db Remote enclosure + electronics: II 2 G Ex db IIC T6 Gb II 2 D Ex tb IIIC T85°C Db Local enclosure + sensor II 2 G Ex db IIC T4…T1 Gb II 2 D Ex tb IIIC T135°C…T345°C Db Pigtail version II 2 G Ex db IIC T4…T3 Gb II 2 D Ex tb IIIC T135°C…T200°C Db |
| IECEx: | Integral: Ex db IIC T4…T2 Gb Ex tb IIIC T135°C…T300°C Db Remote enclosure + electronics: Ex db IIC T6 Gb Ex tb IIIC T85°C Db Local enclosure + sensor Ex db IIC T4…T1 Gb Ex tb IIIC T135°C…T345°C Db Pigtail version Ex db IIC T4…T3 Gb Ex tb IIIC T135°C…T200°C Db |
Optional N.I.S.T. Flow Calibration Services
Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
Flow Element
Materials of Construction: All welded 316L stainless steel for all wetted surfaces.
Process Connection:
- Standard: 0.75 inch male NPT
- Optional: 1 inch male NPT, flanges or retractable sensing element.
Insertion Length:
- 1.2 inch [30 mm]
- 2 inches [51 mm]
- 4 inches [102 mm]
- 6 inches [152 mm]
- 9 inches [229 mm]
- 12 inches [305 mm]
- 18 inches [457 mm]
Customer specified lengths are available as an option.
Operating Temperature:
- Standard: -40° to +350° F [-40° to +177° C]
- Optional: -100° to +500° F [-73° to +260° C] or -100° to +850° F [-73° to +454° C]
- Operating Pressure: To 3500 psig [240 bar(g)]
Control Circuit
Operating Temperature: -40° to +140° F [-40° to +60° C]
Universal AC/DC supply. Input terminals and jumpers on circut board select specific power.
| AC | 108-132V | 13W, 100mA max. |
| AC | 207-253V* | 14W, 50mA max. |
| AC | 18-28V | 7W, 230mA max. |
| DC | 21-30V | 7W, 230mA max. |
* AC mains preset by factory: FM & FMc as 108-132 Vac; All others as 207-240 Vac
Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc.
Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.
Electrical Connection: 1 inch female NPT
Remote Configuration: Available as an option with customer specified interconnecting cable length.
To contact AMS Instrumentation & Calibration about FCI Insertion Flow Switch | FlexSwitch FLT93S use Get a quote.
This product was designed for heavy industrial environments including high temperature and high pressure. FCI is the only thermal manufacturer providing temperature compensation to ensure set point accuracy for process temperatures that vary up to ± 100° F.
The FLT93S is easily field-configured or factory preset, providing unparalleled flexibility, accuracy and stability for all multiple process sensing and switching requirements.
Applications:
- Pump protection
- Cooling water/heat exchangers
- Drain line flow
- Safety spray nozzle monitoring
- Oil well system testing
- Relief valve monitoring
- Venting Assurance
Specifications:
For Flow Service - Setpoint Range:
- Water-based Liquids:
0.01 to 3.0 fps [0.003 to 0.9 mps]
- Hydrocarbon-based Liquids:
0.01 to 5.0 fps [0.003 to 1.5 mps]
- Air/Gas:
0.25 to 120 sfps [0.08 to 37 smps] at standard conditions of 70° F [21.1° C] and 14.7 psia [1.013 bar(g)].
Accuracy: (whichever reading is higher)
- Liquids: ± 0.5% reading or ± 0.04 fps [± 0.012 mps]
- Gases: ± 0.5% reading or ± 2 sfps [± 0.06 nmps]
For Temperature Service:
Accuracy: ± 2° F [±1° C]
Repeatability: ± 1° F [± 0.6° C]
Response Time: As low as 3 seconds.
Enclosure: NEMA 4X/IP66 Rated. Standard: Polyester powder coated aluminum, with single 1" NPT conduit port. Optional: Stainless steel. Optional: Dual-conduit port, aluminum with 1/2" NPT or M20 metric conduit ports.
Compliances and Agency Approvals: FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro. CE mark. PED, CRN.
Meets EC directives for EMC and LVD. Probe complies with Canadian Electrical code requirements of ANSI/ISA 12.27.01-2011 as a single seal device.
| FM/FMc: | XP, Class 1, Div. 1 Groups B,C,D, T3A or T4 Ta =60°C DIP, Class II/III, Div. 1, Groups E,F,G, T3A or T4 Ta =60°C Nonincendive for Class I, II and III, Division 2, Groups A,B,C,D,E,F, and G, T3A or T4 -40°C =Ta=60°C; hazardous (classified) locations, indoors and outdoors. Type 4X |
| ATEX: | Integral: II 2 G Ex db IIC T4…T2 Gb II 2 D Ex tb IIIC T135°C…T300°C Db Remote enclosure + electronics: II 2 G Ex db IIC T6 Gb II 2 D Ex tb IIIC T85°C Db Local enclosure + sensor II 2 G Ex db IIC T4…T1 Gb II 2 D Ex tb IIIC T135°C…T345°C Db Pigtail version II 2 G Ex db IIC T4…T3 Gb II 2 D Ex tb IIIC T135°C…T200°C Db |
| IECEx: | Integral: Ex db IIC T4…T2 Gb Ex tb IIIC T135°C…T300°C Db Remote enclosure + electronics: Ex db IIC T6 Gb Ex tb IIIC T85°C Db Local enclosure + sensor Ex db IIC T4…T1 Gb Ex tb IIIC T135°C…T345°C Db Pigtail version Ex db IIC T4…T3 Gb Ex tb IIIC T135°C…T200°C Db |
Optional N.I.S.T. Flow Calibration Services
Factory N.I.S.T. calibration in air or water is available as an option for customer specified setpoint(s) or a flow curve based on the media ranges specified above.
Flow Element
Materials of Construction: All welded 316L stainless steel for all wetted surfaces.
Process Connection:
- Standard: 0.75 inch male NPT
- Optional: 1 inch male NPT, flanges or retractable sensing element.
Insertion Length:
- 1.2 inch [30 mm]
- 2 inches [51 mm]
- 4 inches [102 mm]
- 6 inches [152 mm]
- 9 inches [229 mm]
- 12 inches [305 mm]
- 18 inches [457 mm]
Customer specified lengths are available as an option.
Operating Temperature:
- Standard: -40° to +350° F [-40° to +177° C]
- Optional: -100° to +500° F [-73° to +260° C] or -100° to +850° F [-73° to +454° C]
- Operating Pressure: To 3500 psig [240 bar(g)]
Control Circuit
Operating Temperature: -40° to +140° F [-40° to +60° C]
Universal AC/DC supply. Input terminals and jumpers on circut board select specific power.
| AC | 108-132V | 13W, 100mA max. |
| AC | 207-253V* | 14W, 50mA max. |
| AC | 18-28V | 7W, 230mA max. |
| DC | 21-30V | 7W, 230mA max. |
* AC mains preset by factory: FM & FMc as 108-132 Vac; All others as 207-240 Vac
Relay Contacts: Field configurable dual SPDT or single DPDT rated 6 amps at 115 Vac, 240 Vac or 24 Vdc.
Output Signal: Analog DC voltage related to flow or level/interface signal and proportional to temperature.
Electrical Connection: 1 inch female NPT
Remote Configuration: Available as an option with customer specified interconnecting cable length.
To contact AMS Instrumentation & Calibration about FCI Insertion Flow Switch | FlexSwitch FLT93S use Get a quote.
The FCI FlexSwitch FLT93S is an insertion flow switch for monitoring flow and temperature and switching at configured process thresholds. Its temperature compensation maintains setpoint accuracy when process temperatures vary by up to ±100° F. For relief-valve monitoring, optional N.I.S.T. calibration is available in air or water for customer-specified setpoints or a flow curve based on the specified media ranges.
- Liquid flow accuracy: ±0.5% of reading or ±0.04 fps, whichever is higher
- Temperature accuracy: ±2° F; repeatability: ±1° F
- Operating pressure up to 3500 psig
- NEMA 4X/IP66-rated enclosure
- Approvals include FM, FMc, ATEX, IECEx, EAC/TR CU, Inmetro, CE, PED and CRN
Source: listing by AMS Instrumentation & Calibration on IndustrySearch · Updated 1 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by AMS Instrumentation & Calibration on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
McMenon Averaging Pitot Tubes | Flow Meter
Hawker Electronics Mini Bubbler Level Measurement and Control System
Flue Gas Emission Analyser | RBR JK2Npro
Mass Flow Meters - FCI ST80/ST80L
Compact Thermal Flow Meter Line Expands With HART Bus Communication
S8000RS Compact Chilled Mirror Hygrometers
Gas Flow Meter - Measures Hydrogen | ST100
McCrometer's V-Cone Flow Meters
Diagnostics Tool for Dew-Point Transmitter
Rotary Piston Flow Meters
SIL 2 Compliant FS10i Flow Switch/Monitor | Flow Detection/Monitoring
Relative Humidity Probe | HygroSmart HS3 | Michell
Air/Gas Flow Meter | FCI ST100 | VeriCal System
Solar Powered Thermal Mass Flow Meter | FCI ST75V
Thermal Mass Flow Meters | FCI ST51A and ST75A
Compact Hygrometer - MDM50
Vortab Elbow Flow Conditioner for Pumps
Process Moisture Analyser | QMA601
ECD Free Chlorine Analyser | Model FC80
Analyser for Dissolved Oxygen, pH, Nitrate | T80
SIL 2 Compliant FS10i Flow Switch/Monitor | Flow Detection/Monitoring
Compact Piston Flow Switches - FS-4
Shuttle Type Flow Switches | FS-200 & FS-200E
High Sensitivity In Line Diaphragm Flow Switches - FS1 / FS1-W
Weatherproof In Line Diaphragm Flow Switches - FS1 / FS1-W
High Sensitivity In Line Diaphragm Flow Switches - FS6
High Sensitivity Weatherproof In Line Diaphragm Flow Switches - FS6
General Purpose In Line Paddle / Piston Flow Switches - FS4-3T
General Purpose In Line Paddle / Piston Flow Switches - FS5
Paddle Type Flow Switches | FS-550 & FS-550E
General Purpose Paddle Flow Switches - FS4-3J
Paddle Flow Switches - FS8
Paddle Flow Switches - FS7-4
Paddle Flow Switches - FS7-4W
Paddle Flow Switch for Liquids | Meister SPM
Level and Flow Switches | LINC-282 Pneumatic Level Switch
Level and Flow Switches | L471 Electric Level Switch
Level and Flow Switches | LINC L471SC Externally Caged Switch
Air Flow Switch – No Flow Switching (Calometric)
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product