Robust design for use in harsh industrial environments
Features:
- Two switching outputs, one of them with IO-Link communication interface
- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
| Product characteristics | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Measuring range |
|
||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Application | |||||||||
| Special feature | Gold-plated contacts | ||||||||
| Measuring element | metallic thin film cell | ||||||||
| Application | for industrial applications | ||||||||
| Media | liquids and gases | ||||||||
| Medium temperature [°C] | -25...80 | ||||||||
| Min. bursting pressure |
|
||||||||
| Pressure rating |
|
||||||||
| Vacuum resistance [mbar] | -1000 | ||||||||
| Type of pressure | relative pressure | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) | ||||||||
| Current consumption [mA] | < 35 | ||||||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] | < 0.3 | ||||||||
| Integrated watchdog | yes | ||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 2 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 2 | ||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||||||||
| Switching frequency DC [Hz] | < 170 | ||||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload protection | yes | ||||||||
| Measuring/setting range | |||||||||
| Measuring range |
|
||||||||
| Factory setting / CMPT = 2 | |||||||||
| Set point SP |
|
||||||||
| Reset point rP |
|
||||||||
| Min. difference between SP and rP |
|
||||||||
| In steps of |
|
||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Set point SP |
|
||||||||
| Reset point rP |
|
||||||||
| Min. difference between SP and rP |
|
||||||||
| In steps of |
|
||||||||
| Accuracy / deviations | |||||||||
| Switch point accuracy [% of the span] | < ± 0,5 | ||||||||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||
| Hysteresis deviation [% of the span] | < ± 0,25 | ||||||||
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||||
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Response times | |||||||||
| Response time [ms] | < 3 | ||||||||
| Delay time programmable dS, dr [s] | 0...50 | ||||||||
| Software / programming | |||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A; (when pin 2 not connected: B) | ||||||||
| Process data analogue | 1 | ||||||||
| Process data binary | 2 | ||||||||
| Supported DeviceIDs |
|
||||||||
| Note |
|
||||||||
| Factory setting / CMPT = 2 | |||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| Min. process cycle time [ms] | 2.3 | ||||||||
| IO-Link resolution pressure [bar] | 1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.1 | ||||||||
| IO-Link process data (cyclical) |
|
||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | ||||||||
| Min. process cycle time [ms] | 3 | ||||||||
| IO-Link resolution pressure [bar] | 0.1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.02 | ||||||||
| IO-Link process data (cyclical) |
|
||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -25...80 | ||||||||
| Storage temperature [°C] | -40...100 | ||||||||
| Protection | IP 65; IP 67 | ||||||||
| Tests / approvals | |||||||||
| EMC |
|
||||||||
| Shock resistance |
|
||||||||
| Vibration resistance |
|
||||||||
| UL approval |
|
||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||
| Mechanical data | |||||||||
| Weight [g] | 239.2 | ||||||||
| Materials | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | ||||||||
| Materials (wetted parts) | 1.4542 (17-4 PH / 630) | ||||||||
| Min. pressure cycles | 100 million | ||||||||
| Tightening torque [Nm] | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) | ||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Restrictor element integrated | no (can be retrofitted) | ||||||||
| Displays / operating elements | |||||||||
| Display |
|
||||||||
| Remarks | |||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
To contact ifm efector about IFM Efector Pressure Sensor with Display | PN7071 use Get a quote.
Features:
- Two switching outputs, one of them with IO-Link communication interface
- Red/green display for clear identification of the acceptable range
- The process connection can be rotated for optimum alignment
- With long-term stability thanks to high overload protection
- Robust design for use in harsh industrial environments
| Product characteristics | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Measuring range |
|
||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Application | |||||||||
| Special feature | Gold-plated contacts | ||||||||
| Measuring element | metallic thin film cell | ||||||||
| Application | for industrial applications | ||||||||
| Media | liquids and gases | ||||||||
| Medium temperature [°C] | -25...80 | ||||||||
| Min. bursting pressure |
|
||||||||
| Pressure rating |
|
||||||||
| Vacuum resistance [mbar] | -1000 | ||||||||
| Type of pressure | relative pressure | ||||||||
| Electrical data | |||||||||
| Operating voltage [V] | 18...30 DC; (to SELV/PELV) | ||||||||
| Current consumption [mA] | < 35 | ||||||||
| Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
| Protection class | III | ||||||||
| Reverse polarity protection | yes | ||||||||
| Power-on delay time [s] | < 0.3 | ||||||||
| Integrated watchdog | yes | ||||||||
| Inputs / outputs | |||||||||
| Number of inputs and outputs | Number of digital outputs: 2 | ||||||||
| Outputs | |||||||||
| Total number of outputs | 2 | ||||||||
| Output signal | switching signal; IO-Link; (configurable) | ||||||||
| Electrical design | PNP/NPN | ||||||||
| Number of digital outputs | 2 | ||||||||
| Output function | normally open / normally closed; (parameterisable) | ||||||||
| Max. voltage drop switching output DC [V] | 2.5 | ||||||||
| Permanent current rating of switching output DC [mA] | 150; (200 (...60 °C) 250 (...40 °C)) | ||||||||
| Switching frequency DC [Hz] | < 170 | ||||||||
| Short-circuit protection | yes | ||||||||
| Type of short-circuit protection | pulsed | ||||||||
| Overload protection | yes | ||||||||
| Measuring/setting range | |||||||||
| Measuring range |
|
||||||||
| Factory setting / CMPT = 2 | |||||||||
| Set point SP |
|
||||||||
| Reset point rP |
|
||||||||
| Min. difference between SP and rP |
|
||||||||
| In steps of |
|
||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Set point SP |
|
||||||||
| Reset point rP |
|
||||||||
| Min. difference between SP and rP |
|
||||||||
| In steps of |
|
||||||||
| Accuracy / deviations | |||||||||
| Switch point accuracy [% of the span] | < ± 0,5 | ||||||||
| Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K) | ||||||||
| Characteristics deviation [% of the span] | < ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting) | ||||||||
| Hysteresis deviation [% of the span] | < ± 0,25 | ||||||||
| Long-term stability [% of the span] | < ± 0,05; (per 6 months) | ||||||||
| Temperature coefficient zero point [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Temperature coefficient span [% of the span / 10 K] | 0,2; (-25...80 °C) | ||||||||
| Response times | |||||||||
| Response time [ms] | < 3 | ||||||||
| Delay time programmable dS, dr [s] | 0...50 | ||||||||
| Software / programming | |||||||||
| Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit | ||||||||
| Interfaces | |||||||||
| Communication interface | IO-Link | ||||||||
| Transmission type | COM2 (38,4 kBaud) | ||||||||
| IO-Link revision | 1.1 | ||||||||
| SDCI standard | IEC 61131-9 | ||||||||
| SIO mode | yes | ||||||||
| Required master port type | A; (when pin 2 not connected: B) | ||||||||
| Process data analogue | 1 | ||||||||
| Process data binary | 2 | ||||||||
| Supported DeviceIDs |
|
||||||||
| Note |
|
||||||||
| Factory setting / CMPT = 2 | |||||||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||||
| Min. process cycle time [ms] | 2.3 | ||||||||
| IO-Link resolution pressure [bar] | 1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.1 | ||||||||
| IO-Link process data (cyclical) |
|
||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Status_B High Resolution / CMPT = 3 | |||||||||
| Profiles | Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000) | ||||||||
| Min. process cycle time [ms] | 3 | ||||||||
| IO-Link resolution pressure [bar] | 0.1 | ||||||||
| IO-Link resolution pressure [MPa] | 0.02 | ||||||||
| IO-Link process data (cyclical) |
|
||||||||
| IO-Link functions (acyclical) | application specific tag | ||||||||
| Operating conditions | |||||||||
| Ambient temperature [°C] | -25...80 | ||||||||
| Storage temperature [°C] | -40...100 | ||||||||
| Protection | IP 65; IP 67 | ||||||||
| Tests / approvals | |||||||||
| EMC |
|
||||||||
| Shock resistance |
|
||||||||
| Vibration resistance |
|
||||||||
| UL approval |
|
||||||||
| Pressure Equipment Directive | Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request | ||||||||
| Mechanical data | |||||||||
| Weight [g] | 239.2 | ||||||||
| Materials | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC | ||||||||
| Materials (wetted parts) | 1.4542 (17-4 PH / 630) | ||||||||
| Min. pressure cycles | 100 million | ||||||||
| Tightening torque [Nm] | 25...35; (recommended tightening torque; depends on lubrication, seal and pressure rating) | ||||||||
| Process connection | threaded connection G 1/4 internal thread | ||||||||
| Restrictor element integrated | no (can be retrofitted) | ||||||||
| Displays / operating elements | |||||||||
| Display |
|
||||||||
| Remarks | |||||||||
| Pack quantity | 1 pcs. | ||||||||
| Electrical connection | |||||||||
| Connection | Connector: 1 x M12; Contacts: gold-plated | ||||||||
To contact ifm efector about IFM Efector Pressure Sensor with Display | PN7071 use Get a quote.
The IFM Efector PN7071 is a pressure sensor with a display that measures relative pressure and provides configurable switching outputs. Its red-and-green display identifies whether pressure is within the acceptable range, making readings clear and easy to interpret. For industrial applications involving liquids or gases, its rotatable process connection helps align the sensor during installation.
- One switching output includes an IO-Link communication interface
- Measuring range: 0...250 bar
- Pressure rating: 500 bar
- IP 65 and IP 67 protection
- M12 connector with gold-plated contacts
Source: listing by ifm efector on IndustrySearch
· Updated 27 Oct 2026
Supplier document: Operational Instruction PN7071 (PDF)
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by ifm efector on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Vision Sensor - 3D | O3M171
Vibration Sensor | VVB001
Compact Speed Sensor for Hazardous Areas | DI602A
Self-Monitoring Temperature Sensor | TCC501
Flow Sensor | SA5000
Compressed Air Meter | SDG207
Radar Level Sensor | LW2720
Pressure Sensor with Display | PN7071
Ultrasonic Diffuse Reflection Sensor | UIT507
Position Sensor for Rising Stem Valves | IX5010
AS-Interface Inductive Sensor | IM5118
Capacitive High-temperature Sensor | KN5121
IO-Link Position Sensors | OPD101
Inductive High-temperature Sensor | I95045
Flow/Pressure sensor | Flow/pressure switches
MAP (Pressure) Sensor
HDO Compensated & Calibrated Pressure Sensors
HCX Amplified Pressure Sensors
RTO Stainless Steel Pressure Sensors
HCA-BARO Barometric Pressure Sensors
HCL Compensated & Calibrated Pressure Sensors
BSDX Amplified Pressure Sensors
Pressure Sensor for Extrusion MERCURY FREE (Gefran K30 Series)
Pressure Sensor P3297
Highly Durable Melt Pressure Sensor
Pressure Sensor | MS5534C Barometer Module
Pressure Sensor | Gems 5482 OEM differential pressure transmitter
Pressure Sensor | Series 2000 Magnehelic Differential Pressure Gage
OEM Strain Gauge Flush Diaphragm High Pressure Sensor | MRA26
OEM Piezo-Resistive Pressure Sensor | MRA21
OEM Flush Diaphragm Piezo-resistive Pressure Sensor | MRA22
OEM Strain Gauge Pressure Sensor | MRA23
High Accuracy Extrusion Pressure Transducer Melt Pressure Sensor
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product