Omega Thermal Dispersion Flow Switches
Omega - Thermal Dispersion Flow Switches Price Guide: $850
The FSW-6000/7000 Series are thermal flow switch monitors designed to monitor flow status and also used to detect level of liquids, air and gas.
A chain of 8 LED’s gives the user a visual indication of the flow rate. In addition, there isalso a dichromatic LED, which shows the switch point status of the unit. The sensing element and connection of the FSW-6000/7000 Series are made with 316 SS. The standard enclosure is glass-filled nylon and is also available in an aluminum enclosure for hazardous environments. The FSW-6000/7000 Series can be made with a great variety of process connections such as threaded, flange, or sanitary.
The FSW-6000/7000 Series line of thermal flow switch monitors is based on the principle of thermal dispersion. A typical configuration uses two platinum Resistance Temperature Detectors (RTD’s) set within the tip of the sensor. One RTD is heated a few degrees above the temperature of the medium and the other RTD is used as a reference, sensing the actual process temperature. The second RTD also monitors the temperature of the medium, as any changes in temperature must be compensated for in the first RTD. As the process medium flows over the tip of the sensor it disperses some of theheat from the first RTD. The temperature change between the two RTD's signals the probe’s electronics and the switch changes state once the set point has reached.
The FSW-6000/7000 Series may be installed in a pipe or tank using the thread or connection provided. Use only the hexagon when tightening to achieve a seal, do not use the body. The body should be rotated after tightening to leave the cable gland in suitable orientation. The FSW-6000/7000 Series is not affected by its fixing position so it may be installed at any angle around the pipe. However, it is recommended that with horizontal pipe runs the sensor should be installed on the side, into the middle of the pipe. In vertical pipes, the FSW-6000/7000 Series should be installed when there is flow in an upward direction against gravity. Care should be taken when installing the sensor that the probe extends clear of the pipe’s internal wall and is fully immersed into the flow. In pipes with smaller diameters, some care should also be taken so that the sensor is not screwed too far into the line.
- Simple to Install and Low Cost
- No Moving Parts-Maintenance Free Reliability
- Optimal Temperature Compensation — Unaffected by Temperature Gradient
- Can Operate in Temperatures up to 120°C (248°F) with Sanitary Option
- Have a Maximum Working Pressure of 4,300 PSI (300 bar)
- Chain of 8 LEDs- Integrated Flow Rate/Setpoint Indication
- Can Be Used as a Level Switch
Specifications
- Accuracy: ±10% of setpoint
- Repeatability: ±1% of setpoint
- Power Supply:
- FSW-6000: 85 to 240 Vac (50/60 Hz)
- FSW-7000: 24 Vdc ±10%
- Temperature Range:
- Process: -20 to 80°C (-4 to 176°F) [sanitary option to 120°C (248°F) for CIP]
- Operating: -20 to 60°C (-4 to 140°F)
- Max Pressure: 300 bar (4351 psi)
- Protection Class: NEMA 4 (IP65)
- Wetted Materials: 316 SS
- Enclosure Material: Glass filled nylon standard or aluminum die cast option
- Process Connection: ½ to 1½ NPT, Tri-Grip™, or flange (others available, consult Flow Engineering Department)
- Output: 250 Vac SPDT 5 A relay
- Switch Point Adjustment: Potentiometer
- Bargraph:
- Green LED: Flow rate above setpoint
- Yellow LED: Flow is at above setpoint
- Red LED: Flow is below setpoint
- Switch Point Status:
- Red LED: No flow
- Green LED: Flow
- Response Time: 1 to 10 seconds
- Max Start up Delay: 12 seconds
- Switching Range: 3 cm/s to 3 m/s (0.09 to 9.84 ft/sec) (liquid), 5 cm/sec to 15 m/sec (0.16 to 49 ft/sec) (gas)
- Dimensions:
- Nylon Head: 88 Dia x 80 mm H (3.5 x 2.5" H)
- Aluminum Head: 88 Dia x 108 mm H (3.5 x 4.25")
- Insertion Length: 13⁄8, 2 and 3" standard, for other lengths consult Flow Engineering
- Maximum insertion Length is 36"
To contact Omega Australia about Omega Thermal Dispersion Flow Switches use Get a quote.
A chain of 8 LED’s gives the user a visual indication of the flow rate. In addition, there isalso a dichromatic LED, which shows the switch point status of the unit. The sensing element and connection of the FSW-6000/7000 Series are made with 316 SS. The standard enclosure is glass-filled nylon and is also available in an aluminum enclosure for hazardous environments. The FSW-6000/7000 Series can be made with a great variety of process connections such as threaded, flange, or sanitary.
The FSW-6000/7000 Series line of thermal flow switch monitors is based on the principle of thermal dispersion. A typical configuration uses two platinum Resistance Temperature Detectors (RTD’s) set within the tip of the sensor. One RTD is heated a few degrees above the temperature of the medium and the other RTD is used as a reference, sensing the actual process temperature. The second RTD also monitors the temperature of the medium, as any changes in temperature must be compensated for in the first RTD. As the process medium flows over the tip of the sensor it disperses some of theheat from the first RTD. The temperature change between the two RTD's signals the probe’s electronics and the switch changes state once the set point has reached.
The FSW-6000/7000 Series may be installed in a pipe or tank using the thread or connection provided. Use only the hexagon when tightening to achieve a seal, do not use the body. The body should be rotated after tightening to leave the cable gland in suitable orientation. The FSW-6000/7000 Series is not affected by its fixing position so it may be installed at any angle around the pipe. However, it is recommended that with horizontal pipe runs the sensor should be installed on the side, into the middle of the pipe. In vertical pipes, the FSW-6000/7000 Series should be installed when there is flow in an upward direction against gravity. Care should be taken when installing the sensor that the probe extends clear of the pipe’s internal wall and is fully immersed into the flow. In pipes with smaller diameters, some care should also be taken so that the sensor is not screwed too far into the line.
- Simple to Install and Low Cost
- No Moving Parts-Maintenance Free Reliability
- Optimal Temperature Compensation — Unaffected by Temperature Gradient
- Can Operate in Temperatures up to 120°C (248°F) with Sanitary Option
- Have a Maximum Working Pressure of 4,300 PSI (300 bar)
- Chain of 8 LEDs- Integrated Flow Rate/Setpoint Indication
- Can Be Used as a Level Switch
Specifications
- Accuracy: ±10% of setpoint
- Repeatability: ±1% of setpoint
- Power Supply:
- FSW-6000: 85 to 240 Vac (50/60 Hz)
- FSW-7000: 24 Vdc ±10%
- Temperature Range:
- Process: -20 to 80°C (-4 to 176°F) [sanitary option to 120°C (248°F) for CIP]
- Operating: -20 to 60°C (-4 to 140°F)
- Max Pressure: 300 bar (4351 psi)
- Protection Class: NEMA 4 (IP65)
- Wetted Materials: 316 SS
- Enclosure Material: Glass filled nylon standard or aluminum die cast option
- Process Connection: ½ to 1½ NPT, Tri-Grip™, or flange (others available, consult Flow Engineering Department)
- Output: 250 Vac SPDT 5 A relay
- Switch Point Adjustment: Potentiometer
- Bargraph:
- Green LED: Flow rate above setpoint
- Yellow LED: Flow is at above setpoint
- Red LED: Flow is below setpoint
- Switch Point Status:
- Red LED: No flow
- Green LED: Flow
- Response Time: 1 to 10 seconds
- Max Start up Delay: 12 seconds
- Switching Range: 3 cm/s to 3 m/s (0.09 to 9.84 ft/sec) (liquid), 5 cm/sec to 15 m/sec (0.16 to 49 ft/sec) (gas)
- Dimensions:
- Nylon Head: 88 Dia x 80 mm H (3.5 x 2.5" H)
- Aluminum Head: 88 Dia x 108 mm H (3.5 x 4.25")
- Insertion Length: 13⁄8, 2 and 3" standard, for other lengths consult Flow Engineering
- Maximum insertion Length is 36"
To contact Omega Australia about Omega Thermal Dispersion Flow Switches use Get a quote.
Omega FSW-6000/7000 Series thermal flow switches monitor flow status and also detect levels of liquids, air and gas. Two platinum RTDs track temperature: one is heated above the medium and flow carries away heat, changing the switch state at its setpoint. For flow-rate monitoring, the switch’s eight-LED bargraph gives the user a visual indication of the rate.
- Wetted materials: 316 stainless steel
- Maximum working pressure: 300 bar
- Process temperature range: -20 to 80°C
- Liquid switching range: 3 cm/s to 3 m/s
- Gas switching range: 5 cm/s to 15 m/s
Source: listing by Omega Australia on IndustrySearch · Updated 7 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by Omega Australia on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
Chemical Metering Pumps Manual or Automatic Operation
High Speed USB Output PX409 Series Pressure Transducer
Thermal Dispersion Flow Switches
Variable Area Flow Meter for Liquid Flow
Signal Conditioner | DRST-BG
Handheld Temperature Humidity Meter with USB and RS232
Multifunctional Environmental Meter
Paperless Humidity/Temperature Chart Recorder
Industrial Metal Pipe HANI Clamp Temperature Sensors
Digital Stroboscope
SIL 2 Compliant FS10i Flow Switch/Monitor | Flow Detection/Monitoring
Thermal Flow Switch | FLT93L
Compact Piston Flow Switches - FS-4
Shuttle Type Flow Switches | FS-200 & FS-200E
High Sensitivity In Line Diaphragm Flow Switches - FS1 / FS1-W
Weatherproof In Line Diaphragm Flow Switches - FS1 / FS1-W
High Sensitivity In Line Diaphragm Flow Switches - FS6
High Sensitivity Weatherproof In Line Diaphragm Flow Switches - FS6
General Purpose In Line Paddle / Piston Flow Switches - FS4-3T
General Purpose In Line Paddle / Piston Flow Switches - FS5
Paddle Type Flow Switches | FS-550 & FS-550E
General Purpose Paddle Flow Switches - FS4-3J
Thermal Dispersion Flow Switches | Kayden Classic 800 Series
Paddle Flow Switch for Liquids | Meister SPM
Level and Flow Switches | LINC-282 Pneumatic Level Switch
Level and Flow Switches | L471 Electric Level Switch
Level and Flow Switches | LINC L471SC Externally Caged Switch
Air Flow Switch – No Flow Switching (Calometric)
Thermal Flow Switch | BFS100
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product