Engineers at natural gas liquids (NGL) fractionation processing facilities will find the Fluid Components International FLT93L Thermal Flow Switch to be a highly reliable solution for process relief valve leak monitoring.
NGL fractionation processing facilities separate ethane, propane, butane and other heavier hydrocarbons from the natural gas stream. Multiple trains and columns are used in this fractional distillation process, and the relief valves are critical safety protection devices.
For the process to work efficiently and safely, the operation requires early and reliable indication when a relief valve leaks or lifts during an overpressure situation. The FLT93L Switch accurately monitors the pressure relief valves for escaping flow with a thermal dispersion technology flow sensing switch/alarm.
In this application, an inline configuration FLT93L is placed on 0.5- and 1-inch (DN15 and DN 25) diameter pipes. The FLT93L Switch detects leaking or seeping gas in the lines to alert the engineer to over pressurisation. It issues a programmed alarm during such events. For the system to work properly, the FLT93L must detect low flows and yet avoid issuing false alarms that could seriously impact plant operations.
The FLT93L Switch offers a number of advantages at NGL facilities in overpressure monitoring. Not all gas flow sensing technologies are able to detect the required low levels of leaking or seeping gas, which can cause an overpressure event that puts plant safety at risk. The opposite situation also can occur where some alternative flow sensing technologies issue nuisance false alarms frequently, disrupting plant operations.
For example, differential pressure (dP) and vane type technologies have been tried in this application with limited success. Problems have been experienced resulting from a lack of low flow detection, mechanical breakdowns, etc.
Beyond accurate monitoring, the FLT93L Switch offers a number of other advantages in this application. It is easy to install and set-up: FCI’s voltage output allows user to see into the process and accurately set the desired trip point. Flexible dual relays are settable by the plant technician for any combination of flow and/or temperature alarms.
FCI’s unique sensor technology combined with temperature compensation circuitry provides unparalleled performance capabilities: The FLT93L Switch’s flow accuracy is ±2% of the setpoint velocity over a ±28°C temperature range. Repeatability is ±0.5% reading.
A wide selection of standard and custom process connections can be provided. The electronic control circuit can be integrally-mounted with the sensing element, or it can be located in a remote location. The standard enclosure is a coated aluminum alloy and is rated for NEMA Type 4X (IP67) environments. Global agency approvals for Ex installations are provided. It is SIL 2 rated for reliability.
To contact AMS Instrumentation & Calibration about Thermal Flow Switch | FLT93L use Get a quote.
NGL fractionation processing facilities separate ethane, propane, butane and other heavier hydrocarbons from the natural gas stream. Multiple trains and columns are used in this fractional distillation process, and the relief valves are critical safety protection devices.
For the process to work efficiently and safely, the operation requires early and reliable indication when a relief valve leaks or lifts during an overpressure situation. The FLT93L Switch accurately monitors the pressure relief valves for escaping flow with a thermal dispersion technology flow sensing switch/alarm.
In this application, an inline configuration FLT93L is placed on 0.5- and 1-inch (DN15 and DN 25) diameter pipes. The FLT93L Switch detects leaking or seeping gas in the lines to alert the engineer to over pressurisation. It issues a programmed alarm during such events. For the system to work properly, the FLT93L must detect low flows and yet avoid issuing false alarms that could seriously impact plant operations.
The FLT93L Switch offers a number of advantages at NGL facilities in overpressure monitoring. Not all gas flow sensing technologies are able to detect the required low levels of leaking or seeping gas, which can cause an overpressure event that puts plant safety at risk. The opposite situation also can occur where some alternative flow sensing technologies issue nuisance false alarms frequently, disrupting plant operations.
For example, differential pressure (dP) and vane type technologies have been tried in this application with limited success. Problems have been experienced resulting from a lack of low flow detection, mechanical breakdowns, etc.
Beyond accurate monitoring, the FLT93L Switch offers a number of other advantages in this application. It is easy to install and set-up: FCI’s voltage output allows user to see into the process and accurately set the desired trip point. Flexible dual relays are settable by the plant technician for any combination of flow and/or temperature alarms.
FCI’s unique sensor technology combined with temperature compensation circuitry provides unparalleled performance capabilities: The FLT93L Switch’s flow accuracy is ±2% of the setpoint velocity over a ±28°C temperature range. Repeatability is ±0.5% reading.
A wide selection of standard and custom process connections can be provided. The electronic control circuit can be integrally-mounted with the sensing element, or it can be located in a remote location. The standard enclosure is a coated aluminum alloy and is rated for NEMA Type 4X (IP67) environments. Global agency approvals for Ex installations are provided. It is SIL 2 rated for reliability.
To contact AMS Instrumentation & Calibration about Thermal Flow Switch | FLT93L use Get a quote.
The Fluid Components International FLT93L is a thermal flow switch that monitors process relief valves for escaping gas and detects leaks in connected lines. Thermal dispersion sensing detects low escaping flows and triggers a programmed alarm, giving engineers early warning when a relief valve leaks or lifts. NGL fractionation engineers can use its voltage output to set the desired trip point while viewing process conditions.
- Dual relays can be set for combinations of flow and/or temperature alarms
- Flow accuracy: ±2% of setpoint velocity over a ±28°C temperature range
- Repeatability: ±0.5% reading
- Inline configuration for 0.5-inch and 1-inch diameter pipes
- The control circuit can be integral with the sensor or located remotely
Source: listing by AMS Instrumentation & Calibration on IndustrySearch · Updated 1 Nov 2026
AI Overview is generated by artificial intelligence and may contain mistakes.
Written by AI from the listing by AMS Instrumentation & Calibration on IndustrySearch. It is meant to use only what that listing says, but it can still get details wrong, so check them with the supplier before you buy.
Thanks for your feedback.
- Your delivery location?
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
- NSW
- VIC
- QLD
- SA
- WA
- NT
- ACT
- TAS
- New Zealand
- Papua New Guinea
- Afghanistan
- Albania
- Algeria
- Andorra
- Angola
- Antigua and Barbuda
- Argentina
- Armenia
- Austria
- Azerbaijan
- Bahamas
- Bahrain
- Bangladesh
- Barbados
- Belarus
- Belgium
- Belize
- Benin
- Bhutan
- Bolivia
- Bosnia and Herzegovina
- Botswana
- Brazil
- Brunei
- Bulgaria
- Burkina Faso
- Burma
- Burundi
- Cabo Verde
- Cambodia
- Cameroon
- Canada
- Central African Republic
- Chad
- Chile
- China
- Colombia
- Comoros
- Congo (Brazzaville)
- Congo (Kinshasa)
- Costa Rica
- Côte d'Ivoire
- Croatia
- Cuba
- Cyprus
- Czechia
- Denmark
- Djibouti
- Dominica
- Dominican Republic
- Ecuador
- Egypt
- El Salvador
- Equatorial Guinea
- Eritrea
- Estonia
- Ethiopia
- Fiji
- Finland
- France
- Gabon
- Gambia
- Georgia
- Germany
- Ghana
- Greece
- Grenada
- Guatemala
- Guinea
- Guinea-Bissau
- Guyana
- Haiti
- Holy See
- Honduras
- Hungary
- Iceland
- India
- Indonesia
- Iran
- Iraq
- Ireland
- Israel
- Italy
- Jamaica
- Japan
- Jordan
- Kazakhstan
- Kenya
- Kiribati
- Korea, North
- Korea, South
- Kosovo
- Kuwait
- Kyrgyzstan
- Laos
- Latvia
- Lebanon
- Lesotho
- Liberia
- Libya
- Liechtenstein
- Lithuania
- Luxembourg
- Macedonia
- Madagascar
- Malawi
- Malaysia
- Maldives
- Mali
- Malta
- Marshall Islands
- Mauritania
- Mauritius
- Mexico
- Federated States of Micronesia
- Moldova
- Monaco
- Mongolia
- Montenegro
- Morocco
- Mozambique
- Namibia
- Nauru
- Nepal
- Netherlands
- New Zealand
- Nicaragua
- Niger
- Nigeria
- Norway
- Oman
- Pakistan
- Palau
- Panama
- Papua New Guinea
- Paraguay
- Peru
- Philippines
- Poland
- Portugal
- Qatar
- Romania
- Russia
- Rwanda
- Saint Kitts and Nevis
- Saint Lucia
- Saint Vincent and the Grenadines
- Samoa
- San Marino
- Sao Tome and Principe
- Saudi Arabia
- Senegal
- Serbia
- Seychelles
- Sierra Leone
- Singapore
- Slovakia
- Slovenia
- Solomon Islands
- Somalia
- South Africa
- South Sudan
- Spain
- Sri Lanka
- Sudan
- Suriname
- Swaziland
- Sweden
- Switzerland
- Syria
- Taiwan
- Tajikistan
- Tanzania
- Thailand
- Timor-Leste
- Togo
- Tonga
- Trinidad and Tobago
- Tunisia
- Turkey
- Turkmenistan
- Tuvalu
- Uganda
- Ukraine
- United Arab Emirates
- United Kingdom
- United States
- Uruguay
- Uzbekistan
- Vanuatu
- Venezuela
- Vietnam
- Yemen
- Zambia
- Zimbabwe
McMenon Averaging Pitot Tubes | Flow Meter
Hawker Electronics Mini Bubbler Level Measurement and Control System
Flue Gas Emission Analyser | RBR JK2Npro
Mass Flow Meters - FCI ST80/ST80L
Compact Thermal Flow Meter Line Expands With HART Bus Communication
S8000RS Compact Chilled Mirror Hygrometers
Gas Flow Meter - Measures Hydrogen | ST100
McCrometer's V-Cone Flow Meters
Diagnostics Tool for Dew-Point Transmitter
Rotary Piston Flow Meters
SIL 2 Compliant FS10i Flow Switch/Monitor | Flow Detection/Monitoring
Relative Humidity Probe | HygroSmart HS3 | Michell
Air/Gas Flow Meter | FCI ST100 | VeriCal System
Solar Powered Thermal Mass Flow Meter | FCI ST75V
Thermal Mass Flow Meters | FCI ST51A and ST75A
Compact Hygrometer - MDM50
Vortab Elbow Flow Conditioner for Pumps
Process Moisture Analyser | QMA601
ECD Free Chlorine Analyser | Model FC80
Analyser for Dissolved Oxygen, pH, Nitrate | T80
SIL 2 Compliant FS10i Flow Switch/Monitor | Flow Detection/Monitoring
Compact Piston Flow Switches - FS-4
Shuttle Type Flow Switches | FS-200 & FS-200E
High Sensitivity In Line Diaphragm Flow Switches - FS1 / FS1-W
Weatherproof In Line Diaphragm Flow Switches - FS1 / FS1-W
High Sensitivity In Line Diaphragm Flow Switches - FS6
High Sensitivity Weatherproof In Line Diaphragm Flow Switches - FS6
General Purpose In Line Paddle / Piston Flow Switches - FS4-3T
General Purpose In Line Paddle / Piston Flow Switches - FS5
Paddle Type Flow Switches | FS-550 & FS-550E
General Purpose Paddle Flow Switches - FS4-3J
Thermal Dispersion Flow Switches | Kayden Classic 800 Series
Paddle Flow Switch for Liquids | Meister SPM
Level and Flow Switches | LINC-282 Pneumatic Level Switch
Level and Flow Switches | L471 Electric Level Switch
Level and Flow Switches | LINC L471SC Externally Caged Switch
Air Flow Switch – No Flow Switching (Calometric)
Thermal Flow Switch | BFS100
Thermal Dispersion Flow Switches
Thanks for your help!
Sorry! Unable to submit your request at this time. Please try again later.
Report this product